Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf

Transformer is a static electrical device that transfers energy from one electrical circuit to another by magnetic coupling. It is often used to convert between high and low voltages and accordingly between low and high currents. A simple single phase transformer consists of two electrical conductor...

Full description

Saved in:
Bibliographic Details
Main Authors: Hussin, Saiful Izwan, Mohamed Yusuf, Noor Mohamad Iptitah
Format: Student Project
Language:English
Published: 2005
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/48143/1/48143.PDF
http://ir.uitm.edu.my/id/eprint/48143/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.48143
record_format eprints
spelling my.uitm.ir.481432021-06-28T07:53:13Z http://ir.uitm.edu.my/id/eprint/48143/ Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf Hussin, Saiful Izwan Mohamed Yusuf, Noor Mohamad Iptitah Electric controllers. Rheostats. Regulators. Starters Applications of electric power Electric apparatus and materials. Electric circuits. Electric networks Electromagnetic fields Transformer is a static electrical device that transfers energy from one electrical circuit to another by magnetic coupling. It is often used to convert between high and low voltages and accordingly between low and high currents. A simple single phase transformer consists of two electrical conductors called the primary coil and the secondary coil. There was two type of transformer; step-up transformer which the secondary coil has more turn then the primary coil and step-down transformer which secondary coil has fewer turns than the primary coil. In this thesis, the transformer is a step-down type. This transformer will step down voltage from 240V to 24V and rating of 75VA. The size and length of the wire have being measure. The number a is need to be calculated, a is ratio of the input voltage per output voltage. To find the turn of coil, the ratio can be used by a is equal to primary turn per secondary turn. If a is higher than 1, it is step-down. If a is small than 1, it is step up. The proposed of project is to make the transformer related the correct voltage. The ratio is 10. By calculating, the number of the primary coil is 1159 turn and secondary coil is 116 turn. The rating also needs to be correct. By calculation also, the size and the length of wire can be measure. 2005-10 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/48143/1/48143.PDF ID48143 Hussin, Saiful Izwan and Mohamed Yusuf, Noor Mohamad Iptitah (2005) Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf. [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Electric controllers. Rheostats. Regulators. Starters
Applications of electric power
Electric apparatus and materials. Electric circuits. Electric networks
Electromagnetic fields
spellingShingle Electric controllers. Rheostats. Regulators. Starters
Applications of electric power
Electric apparatus and materials. Electric circuits. Electric networks
Electromagnetic fields
Hussin, Saiful Izwan
Mohamed Yusuf, Noor Mohamad Iptitah
Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf
description Transformer is a static electrical device that transfers energy from one electrical circuit to another by magnetic coupling. It is often used to convert between high and low voltages and accordingly between low and high currents. A simple single phase transformer consists of two electrical conductors called the primary coil and the secondary coil. There was two type of transformer; step-up transformer which the secondary coil has more turn then the primary coil and step-down transformer which secondary coil has fewer turns than the primary coil. In this thesis, the transformer is a step-down type. This transformer will step down voltage from 240V to 24V and rating of 75VA. The size and length of the wire have being measure. The number a is need to be calculated, a is ratio of the input voltage per output voltage. To find the turn of coil, the ratio can be used by a is equal to primary turn per secondary turn. If a is higher than 1, it is step-down. If a is small than 1, it is step up. The proposed of project is to make the transformer related the correct voltage. The ratio is 10. By calculating, the number of the primary coil is 1159 turn and secondary coil is 116 turn. The rating also needs to be correct. By calculation also, the size and the length of wire can be measure.
format Student Project
author Hussin, Saiful Izwan
Mohamed Yusuf, Noor Mohamad Iptitah
author_facet Hussin, Saiful Izwan
Mohamed Yusuf, Noor Mohamad Iptitah
author_sort Hussin, Saiful Izwan
title Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf
title_short Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf
title_full Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf
title_fullStr Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf
title_full_unstemmed Development of step-down transformer (240v-24v) / Saiful Izwan Hussin and Noor Mohamad Iptitah Mohamed Yusuf
title_sort development of step-down transformer (240v-24v) / saiful izwan hussin and noor mohamad iptitah mohamed yusuf
publishDate 2005
url http://ir.uitm.edu.my/id/eprint/48143/1/48143.PDF
http://ir.uitm.edu.my/id/eprint/48143/
_version_ 1703963509896773632
score 13.211869