Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das
A topology for multilevel voltage space phasor generation for an open-end winding induction motor drive is presented in this paper. The open-end winding induction motor is fed from both ends by two 3-level inverters. Each 3-level inverter is formed by cascading two 2-level inverters. This results in...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
UiTM Press
2008
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/46933/1/46933.pdf https://ir.uitm.edu.my/id/eprint/46933/ https://jeesr.uitm.edu.my/v1/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.46933 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.469332022-06-16T04:31:10Z https://ir.uitm.edu.my/id/eprint/46933/ Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das Sekhar, K. Chandra Ram Das, G. Tulasi (Dr.) TK Electrical engineering. Electronics. Nuclear engineering A topology for multilevel voltage space phasor generation for an open-end winding induction motor drive is presented in this paper. The open-end winding induction motor is fed from both ends by two 3-level inverters. Each 3-level inverter is formed by cascading two 2-level inverters. This results in voltage space phasor levels equivalent to a conventional 8-level inverter. The proposed 8- level inverter configuration requires lesser number of switching devices as compared to conventional 8-level inverter scheme. Compared to the H-bridge topology, the proposed scheme uses a lower number of power supplies. In the multilevel carrier-based Sinusoidal Pulse Width Modulation (SPWM), used for the proposed drive, a progressive discrete DC bias depending on the speed range is given to the reference wave so that the drive can operate in the i-level modes (i=2, 3, …8) depending on the speed range. The inverter with the higher DC-link voltage is switching less frequently, compared to the inverter with the lower DC-link voltage. UiTM Press 2008-06 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/46933/1/46933.pdf Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das. (2008) Journal of Electrical and Electronic Systems Research (JEESR), 1: 1. pp. 1-10. ISSN 1985-5389 https://jeesr.uitm.edu.my/v1/ |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics. Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics. Nuclear engineering Sekhar, K. Chandra Ram Das, G. Tulasi (Dr.) Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das |
description |
A topology for multilevel voltage space phasor generation for an open-end winding induction motor drive is presented in this paper. The open-end winding induction motor is fed from both ends by two 3-level inverters. Each 3-level inverter is formed by cascading two 2-level inverters. This results in voltage space phasor levels equivalent to a conventional 8-level inverter. The proposed 8- level inverter configuration requires lesser number of switching devices as compared to conventional 8-level inverter scheme. Compared to the H-bridge topology, the proposed scheme uses a lower number of power supplies. In the multilevel carrier-based Sinusoidal Pulse Width Modulation (SPWM), used for the proposed drive, a progressive discrete DC bias depending on the speed range is given to the reference wave so that the drive can operate in the i-level modes (i=2, 3, …8) depending on the speed range. The inverter with the higher DC-link voltage is switching less frequently, compared to the inverter with the lower DC-link voltage. |
format |
Article |
author |
Sekhar, K. Chandra Ram Das, G. Tulasi (Dr.) |
author_facet |
Sekhar, K. Chandra Ram Das, G. Tulasi (Dr.) |
author_sort |
Sekhar, K. Chandra |
title |
Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das |
title_short |
Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das |
title_full |
Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das |
title_fullStr |
Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das |
title_full_unstemmed |
Multilevel voltage space phasor generation for an open-end winding induction motor drive / K. Chandra Sekhar and Dr. G. Tulasi Ram Das |
title_sort |
multilevel voltage space phasor generation for an open-end winding induction motor drive / k. chandra sekhar and dr. g. tulasi ram das |
publisher |
UiTM Press |
publishDate |
2008 |
url |
https://ir.uitm.edu.my/id/eprint/46933/1/46933.pdf https://ir.uitm.edu.my/id/eprint/46933/ https://jeesr.uitm.edu.my/v1/ |
_version_ |
1736837231885156352 |
score |
13.211869 |