The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin

Alternating current field measurement (ACFM) technique is an electromagnetic inspection method that uses hand-held probes, computerized control, data acquisition and computational model. This technique has been developed for the accurate detection and sizing of defects through coatings and know both...

Full description

Saved in:
Bibliographic Details
Main Author: Zainal Abidin, Ahmad Zubir
Format: Student Project
Language:English
Published: 2010
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/46617/1/46617.pdf
https://ir.uitm.edu.my/id/eprint/46617/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.46617
record_format eprints
spelling my.uitm.ir.466172022-11-22T07:24:25Z https://ir.uitm.edu.my/id/eprint/46617/ The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin Zainal Abidin, Ahmad Zubir Electric current (General) Alternating current field measurement (ACFM) technique is an electromagnetic inspection method that uses hand-held probes, computerized control, data acquisition and computational model. This technique has been developed for the accurate detection and sizing of defects through coatings and know both the length and depth of the defects. Furthermore, it is more efficient than conventional inspection method for example Ultrasonic Testing (UT), Radiography Testing (RT) and Magnetic Particle Testing (MPT). This research present two case studies where the designing of ACFM calibration block with the difference depths and also to measure the maximum depth of crack on surface material that can be reached at certain condition. The mild steel material is used as sample and the defect surface is tested by using the ACFM technique. Results from the experimentally suggest that ACFM can be an extremely useful method to determine flaw size, but that a knowledge of the limitations of the technique must also be well understood. 2010 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/46617/1/46617.pdf The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin. (2010) [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Electric current (General)
spellingShingle Electric current (General)
Zainal Abidin, Ahmad Zubir
The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin
description Alternating current field measurement (ACFM) technique is an electromagnetic inspection method that uses hand-held probes, computerized control, data acquisition and computational model. This technique has been developed for the accurate detection and sizing of defects through coatings and know both the length and depth of the defects. Furthermore, it is more efficient than conventional inspection method for example Ultrasonic Testing (UT), Radiography Testing (RT) and Magnetic Particle Testing (MPT). This research present two case studies where the designing of ACFM calibration block with the difference depths and also to measure the maximum depth of crack on surface material that can be reached at certain condition. The mild steel material is used as sample and the defect surface is tested by using the ACFM technique. Results from the experimentally suggest that ACFM can be an extremely useful method to determine flaw size, but that a knowledge of the limitations of the technique must also be well understood.
format Student Project
author Zainal Abidin, Ahmad Zubir
author_facet Zainal Abidin, Ahmad Zubir
author_sort Zainal Abidin, Ahmad Zubir
title The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin
title_short The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin
title_full The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin
title_fullStr The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin
title_full_unstemmed The evaluation of alternating current field measurement (ACFM) response on mild steel surface defect / Ahmad Zubir Zainal Abidin
title_sort evaluation of alternating current field measurement (acfm) response on mild steel surface defect / ahmad zubir zainal abidin
publishDate 2010
url https://ir.uitm.edu.my/id/eprint/46617/1/46617.pdf
https://ir.uitm.edu.my/id/eprint/46617/
_version_ 1751539828063731712
score 13.18916