Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili

Saccharin is one of the most well-known artificial sweeteners that widely used since a long time ago. Saccharin is commonly used as sweeteners to replace sugar in foods and beverages as it is 300-400 times sweeter than sugar. The presence of saccharin that exceeds the permitted level of 80 mg L-1 fo...

Full description

Saved in:
Bibliographic Details
Main Author: Roslaili, Muhammad Nuaim Rifqi
Format: Student Project
Language:English
Published: 2019
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/45200/1/45200.pdf
http://ir.uitm.edu.my/id/eprint/45200/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.45200
record_format eprints
spelling my.uitm.ir.452002021-06-21T07:10:37Z http://ir.uitm.edu.my/id/eprint/45200/ Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili Roslaili, Muhammad Nuaim Rifqi Spectroscopy Organic chemistry Analytical chemistry Saccharin is one of the most well-known artificial sweeteners that widely used since a long time ago. Saccharin is commonly used as sweeteners to replace sugar in foods and beverages as it is 300-400 times sweeter than sugar. The presence of saccharin that exceeds the permitted level of 80 mg L-1 for soft drinks from plant extracts will cause severe health effect to the consumers. Hence, the amount of saccharin in beverages products must be analyzed. A sensitive, accurate, simple, rapid and low cost analytical method is required for the determination of saccharin. The spectrophotometric method has been proposed for the quantitative analysis of saccharin. The calibration curve was linear from 2 mg L-1 to 9 mg L-1 of saccharin standard solution with a regression coefficient (R2) of 0.9997. The limit of detection (LOD) obtained was 0.25 mg L-1. The precisions in terms of relative standard deviation (RSD) were 2.69 %, 2.64 % and 0.74 % for 2 mg L-1 saccharin in consecutive three days. Meanwhile, the RSD were 0.46 %, 0.31 % and 0.30 % for 4 mg L-1. Lastly for concentration of 8 mg L-1, the RSD were 0.08 %, 0.33 % and 0.08 %. The range of recovery achieved for 2, 5 and 8 mg L-1 of saccharin standard solution in the instant tea products were 89.17 %, 96.99 % and 101.55 % respectively. All tested instant tea products contain no saccharin except for instant tea powder (A2) which 4.24 mg L-1. So, it can be concluded that this proposed method is accurate, simple, fast, low cost and has a potential to be an alternative method for routine analysis of saccharin in instant tea products. 2019-07 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/45200/1/45200.pdf ID45200 Roslaili, Muhammad Nuaim Rifqi (2019) Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili. [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Spectroscopy
Organic chemistry
Analytical chemistry
spellingShingle Spectroscopy
Organic chemistry
Analytical chemistry
Roslaili, Muhammad Nuaim Rifqi
Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili
description Saccharin is one of the most well-known artificial sweeteners that widely used since a long time ago. Saccharin is commonly used as sweeteners to replace sugar in foods and beverages as it is 300-400 times sweeter than sugar. The presence of saccharin that exceeds the permitted level of 80 mg L-1 for soft drinks from plant extracts will cause severe health effect to the consumers. Hence, the amount of saccharin in beverages products must be analyzed. A sensitive, accurate, simple, rapid and low cost analytical method is required for the determination of saccharin. The spectrophotometric method has been proposed for the quantitative analysis of saccharin. The calibration curve was linear from 2 mg L-1 to 9 mg L-1 of saccharin standard solution with a regression coefficient (R2) of 0.9997. The limit of detection (LOD) obtained was 0.25 mg L-1. The precisions in terms of relative standard deviation (RSD) were 2.69 %, 2.64 % and 0.74 % for 2 mg L-1 saccharin in consecutive three days. Meanwhile, the RSD were 0.46 %, 0.31 % and 0.30 % for 4 mg L-1. Lastly for concentration of 8 mg L-1, the RSD were 0.08 %, 0.33 % and 0.08 %. The range of recovery achieved for 2, 5 and 8 mg L-1 of saccharin standard solution in the instant tea products were 89.17 %, 96.99 % and 101.55 % respectively. All tested instant tea products contain no saccharin except for instant tea powder (A2) which 4.24 mg L-1. So, it can be concluded that this proposed method is accurate, simple, fast, low cost and has a potential to be an alternative method for routine analysis of saccharin in instant tea products.
format Student Project
author Roslaili, Muhammad Nuaim Rifqi
author_facet Roslaili, Muhammad Nuaim Rifqi
author_sort Roslaili, Muhammad Nuaim Rifqi
title Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili
title_short Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili
title_full Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili
title_fullStr Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili
title_full_unstemmed Spectrophotometric analysis of saccharin in instant tea products / Muhammad Nuaim Rifqi Roslaili
title_sort spectrophotometric analysis of saccharin in instant tea products / muhammad nuaim rifqi roslaili
publishDate 2019
url http://ir.uitm.edu.my/id/eprint/45200/1/45200.pdf
http://ir.uitm.edu.my/id/eprint/45200/
_version_ 1703963387342356480
score 13.210693