Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali
This is study to evaluate of solar heat gain and day lighting through building at facing east and west. A test cell located in the campus UITM Shah Alam is used as a case study. Data of the internal and external surface temperature for walls and window at facing east and west were measured using the...
Saved in:
Main Author: | |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/44299/1/44299.pdf http://ir.uitm.edu.my/id/eprint/44299/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.44299 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.442992021-03-29T04:43:37Z http://ir.uitm.edu.my/id/eprint/44299/ Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali Ghazali, Zatul Izzati Farahiyah Heat This is study to evaluate of solar heat gain and day lighting through building at facing east and west. A test cell located in the campus UITM Shah Alam is used as a case study. Data of the internal and external surface temperature for walls and window at facing east and west were measured using thermo couple type T. In this experiment, the vertical glazing solar material were used for the windows. Three types of control system material were Control, System 1 and System 2. The data were recorded in on automated data logging system at an interval of 5 minutes for a duration of 14 days using data logger. The solar heat gain for each orientation were calculated and compared with the Control system. The value of visible transmittance of Control is 88% while System 1 and System 2 are 0.29 and 0.25. the value of thermal transmittance for Control is 5.893 W/m2oK while the System 1 and Syatem 2 are 0.855 W/m2°K and 2.717 W/m2oK. The result showed that the Control system is the highest heat transfer than other system based on the thermal and optical properties of the window. 2012-01 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/44299/1/44299.pdf Ghazali, Zatul Izzati Farahiyah (2012) Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali. [Student Project] (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Heat |
spellingShingle |
Heat Ghazali, Zatul Izzati Farahiyah Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali |
description |
This is study to evaluate of solar heat gain and day lighting through building at facing east and west. A test cell located in the campus UITM Shah Alam is used as a case study. Data of the internal and external surface temperature for walls and window at facing east and west were measured using thermo couple type T. In this experiment, the vertical glazing solar material were used for the windows. Three types of control system material were Control, System 1 and System 2. The data were recorded in on automated data logging system at an interval of 5 minutes for a duration of 14 days using data logger. The solar heat gain for each orientation were calculated and compared with the Control system. The value of visible transmittance of Control is 88% while System 1 and System 2 are 0.29 and 0.25. the value of thermal transmittance for Control is 5.893 W/m2oK while the System 1 and Syatem 2 are 0.855 W/m2°K and 2.717 W/m2oK. The result showed that the Control system is the highest heat transfer than other system based on the thermal and optical properties of the window. |
format |
Student Project |
author |
Ghazali, Zatul Izzati Farahiyah |
author_facet |
Ghazali, Zatul Izzati Farahiyah |
author_sort |
Ghazali, Zatul Izzati Farahiyah |
title |
Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali |
title_short |
Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali |
title_full |
Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali |
title_fullStr |
Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali |
title_full_unstemmed |
Evaluation of solar heat gain and day lighting through building envelope in Malaysia : a case study of UiTM test cell / Zatul Izzati Farahiyah Ghazali |
title_sort |
evaluation of solar heat gain and day lighting through building envelope in malaysia : a case study of uitm test cell / zatul izzati farahiyah ghazali |
publishDate |
2012 |
url |
http://ir.uitm.edu.my/id/eprint/44299/1/44299.pdf http://ir.uitm.edu.my/id/eprint/44299/ |
_version_ |
1696979099717730304 |
score |
13.18916 |