Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin

Yearly, four million people to die because of diabetes and it also leads people to other serious disease. Hence, the existence of the portable blood glucose self check device is very helpful to the patients and others who concern to know their blood glucose reading. Non-invasive method is more prefe...

Full description

Saved in:
Bibliographic Details
Main Author: Shamsuddin, Sarah Addyani
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/39609/1/39609.pdf
https://ir.uitm.edu.my/id/eprint/39609/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.39609
record_format eprints
spelling my.uitm.ir.396092022-08-11T04:04:49Z https://ir.uitm.edu.my/id/eprint/39609/ Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin Shamsuddin, Sarah Addyani Medical technology Medical physics. Medical radiology. Nuclear medicine Clinical pathology. Laboratory technique Yearly, four million people to die because of diabetes and it also leads people to other serious disease. Hence, the existence of the portable blood glucose self check device is very helpful to the patients and others who concern to know their blood glucose reading. Non-invasive method is more preferable since it should be painless compared to conventional finger pricking device. Besides, patients who need to do self test often need to refer to the procedures and storing surrounding condition which can be hassle to some people with language restriction. Alternatively, using non-invasive will not be wasteful and the measurement or reading can be done any time and numbers of time. Previously, many researches had been done on non-invasive using near-infrared sensing. From previous research by Sia, he had investigated near-infrared sensing using signal penetrating finger method. However, by using finger penetration, there are no results obtained. He only obtained signal using glucose concentration. Therefore the objectives of this research are to investigate the performance of three different wavelength of sensors; infrared 940nm and infrared 950nm and also near infrared 1450nm. Sensor that gave the best output had been chosen to achieve the second objective of this project which is to design non-invasive blood glucose measurement device based on optical sensing and to develop prototype of a blood glucose optical sensing instrumentation with acceptable accuracy and repeatability. Generally, the overall system consists of three parts including sensor part, signal conditioning circuit, and also numerical display. The initial design tested by considering initial voltage 1.616Vto 1.68V which referred to previous research by Sia as the output of the sensor. Then proceed by using test tube which contains various percentage of glucose concentration. The same methods had been used to the human samples fingers instead of test tube. From the experiment, output graph of the 950nm shows more consistent pattern compared to the 940nm. 950nm also has a larger range scale for voltage which from 5.016V to 5.4633V compare to the 940nm voltage range scale which from 5.0327V to 5.4201V. Further test on human finger had been done by using 950nm infrared but the output voltages were too small. The performance of the measurement can be improved by controlling the surrounding condition and fixed the path length between transmitter and receiver. Test using test tube showed that the near infrared and infrared were capable to predict different glucose concentration. By comparing the performance of infrared and near-infrared, near-infrared gave better performance since near-infrared had higher output voltage range which from 0.6 to 3.4174V compared to infrared. Graph near-infrared output voltage shows that the voltage is almost directly proportional to the percentage of glucose concentrations. By using circuit designed, it can be seen that the voltage reading became higher compared to before meal which shows that there were increment in glucose reading from before to after meal. Therefore, it can be concluded that the circuit design functions accordingly and non-invasively. During human sample test, increment pattern can be seen from fasting to non-fasting condition but the main effect is all samples have different fingers' diameter which each of user needs to be calibrated. 2015-03 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/39609/1/39609.pdf Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin. (2015) Masters thesis, thesis, Universiti Teknologi MARA. <http://terminalib.uitm.edu.my/39609.pdf>
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Medical technology
Medical physics. Medical radiology. Nuclear medicine
Clinical pathology. Laboratory technique
spellingShingle Medical technology
Medical physics. Medical radiology. Nuclear medicine
Clinical pathology. Laboratory technique
Shamsuddin, Sarah Addyani
Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin
description Yearly, four million people to die because of diabetes and it also leads people to other serious disease. Hence, the existence of the portable blood glucose self check device is very helpful to the patients and others who concern to know their blood glucose reading. Non-invasive method is more preferable since it should be painless compared to conventional finger pricking device. Besides, patients who need to do self test often need to refer to the procedures and storing surrounding condition which can be hassle to some people with language restriction. Alternatively, using non-invasive will not be wasteful and the measurement or reading can be done any time and numbers of time. Previously, many researches had been done on non-invasive using near-infrared sensing. From previous research by Sia, he had investigated near-infrared sensing using signal penetrating finger method. However, by using finger penetration, there are no results obtained. He only obtained signal using glucose concentration. Therefore the objectives of this research are to investigate the performance of three different wavelength of sensors; infrared 940nm and infrared 950nm and also near infrared 1450nm. Sensor that gave the best output had been chosen to achieve the second objective of this project which is to design non-invasive blood glucose measurement device based on optical sensing and to develop prototype of a blood glucose optical sensing instrumentation with acceptable accuracy and repeatability. Generally, the overall system consists of three parts including sensor part, signal conditioning circuit, and also numerical display. The initial design tested by considering initial voltage 1.616Vto 1.68V which referred to previous research by Sia as the output of the sensor. Then proceed by using test tube which contains various percentage of glucose concentration. The same methods had been used to the human samples fingers instead of test tube. From the experiment, output graph of the 950nm shows more consistent pattern compared to the 940nm. 950nm also has a larger range scale for voltage which from 5.016V to 5.4633V compare to the 940nm voltage range scale which from 5.0327V to 5.4201V. Further test on human finger had been done by using 950nm infrared but the output voltages were too small. The performance of the measurement can be improved by controlling the surrounding condition and fixed the path length between transmitter and receiver. Test using test tube showed that the near infrared and infrared were capable to predict different glucose concentration. By comparing the performance of infrared and near-infrared, near-infrared gave better performance since near-infrared had higher output voltage range which from 0.6 to 3.4174V compared to infrared. Graph near-infrared output voltage shows that the voltage is almost directly proportional to the percentage of glucose concentrations. By using circuit designed, it can be seen that the voltage reading became higher compared to before meal which shows that there were increment in glucose reading from before to after meal. Therefore, it can be concluded that the circuit design functions accordingly and non-invasively. During human sample test, increment pattern can be seen from fasting to non-fasting condition but the main effect is all samples have different fingers' diameter which each of user needs to be calibrated.
format Thesis
author Shamsuddin, Sarah Addyani
author_facet Shamsuddin, Sarah Addyani
author_sort Shamsuddin, Sarah Addyani
title Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin
title_short Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin
title_full Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin
title_fullStr Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin
title_full_unstemmed Design and development of an optical blood glucose measurement for infrared and near-infrared testing / Sarah Addyani Shamsuddin
title_sort design and development of an optical blood glucose measurement for infrared and near-infrared testing / sarah addyani shamsuddin
publishDate 2015
url https://ir.uitm.edu.my/id/eprint/39609/1/39609.pdf
https://ir.uitm.edu.my/id/eprint/39609/
_version_ 1743110375428063232
score 13.160551