Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.]

Solar pond is an integrated solar collector and storage. An experimental salinity gradient solar pond was constructed to analyse the thermal storage capability. The solar pond consist of 2.4 m², 1.4 m deep with sodium chloride (NaCl) as the salt solution. For the development of salinity gradient, a...

Full description

Saved in:
Bibliographic Details
Main Authors: Baharin, Nuraida ‘Aadilia, Muhaimin Yazit, Idznie Faidhi, Bhathal Singh, Baljit Singh, Remeli, Muhammad Fairuz, Oberoi, Amandeep
Format: Article
Language:English
Published: Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM) 2017
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/39350/1/39350.pdf
http://ir.uitm.edu.my/id/eprint/39350/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.39350
record_format eprints
spelling my.uitm.ir.393502020-12-18T03:18:29Z http://ir.uitm.edu.my/id/eprint/39350/ Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.] Baharin, Nuraida ‘Aadilia Muhaimin Yazit, Idznie Faidhi Bhathal Singh, Baljit Singh Remeli, Muhammad Fairuz Oberoi, Amandeep Engineering machinery, tools, and implements TJ Mechanical engineering and machinery Solar pond is an integrated solar collector and storage. An experimental salinity gradient solar pond was constructed to analyse the thermal storage capability. The solar pond consist of 2.4 m², 1.4 m deep with sodium chloride (NaCl) as the salt solution. For the development of salinity gradient, a diffuser was used to develop the salinity gradient. The salinity gradient solar pond consists lower convective zone (LCZ) with a height of 0.5 m with 1200 kg/m3 density, non-convective zone (NCZ) with a height 0.8 m and upper convective zone (UCZ) with a height 10 cm. The temperature of (LCZ) as heat storage was recorded and analysed weekly. Maximum temperature of (LCZ) storage zone was recorded to be at 36.5 °C after four weeks and it showed and upward trend. The heat energy stored in (LCZ) can be used for power generation. Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM) 2017 Article PeerReviewed text en http://ir.uitm.edu.my/id/eprint/39350/1/39350.pdf Baharin, Nuraida ‘Aadilia and Muhaimin Yazit, Idznie Faidhi and Bhathal Singh, Baljit Singh and Remeli, Muhammad Fairuz and Oberoi, Amandeep (2017) Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.]. Journal of Mechanical Engineering (JMechE), SI 4 (5). pp. 217-235. ISSN 18235514
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Engineering machinery, tools, and implements
TJ Mechanical engineering and machinery
spellingShingle Engineering machinery, tools, and implements
TJ Mechanical engineering and machinery
Baharin, Nuraida ‘Aadilia
Muhaimin Yazit, Idznie Faidhi
Bhathal Singh, Baljit Singh
Remeli, Muhammad Fairuz
Oberoi, Amandeep
Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.]
description Solar pond is an integrated solar collector and storage. An experimental salinity gradient solar pond was constructed to analyse the thermal storage capability. The solar pond consist of 2.4 m², 1.4 m deep with sodium chloride (NaCl) as the salt solution. For the development of salinity gradient, a diffuser was used to develop the salinity gradient. The salinity gradient solar pond consists lower convective zone (LCZ) with a height of 0.5 m with 1200 kg/m3 density, non-convective zone (NCZ) with a height 0.8 m and upper convective zone (UCZ) with a height 10 cm. The temperature of (LCZ) as heat storage was recorded and analysed weekly. Maximum temperature of (LCZ) storage zone was recorded to be at 36.5 °C after four weeks and it showed and upward trend. The heat energy stored in (LCZ) can be used for power generation.
format Article
author Baharin, Nuraida ‘Aadilia
Muhaimin Yazit, Idznie Faidhi
Bhathal Singh, Baljit Singh
Remeli, Muhammad Fairuz
Oberoi, Amandeep
author_facet Baharin, Nuraida ‘Aadilia
Muhaimin Yazit, Idznie Faidhi
Bhathal Singh, Baljit Singh
Remeli, Muhammad Fairuz
Oberoi, Amandeep
author_sort Baharin, Nuraida ‘Aadilia
title Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.]
title_short Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.]
title_full Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.]
title_fullStr Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.]
title_full_unstemmed Construction and Operations of First Salinity Gradient Solar Pond in Malaysia / Nuraida ‘Aadilia Baharin ...[et al.]
title_sort construction and operations of first salinity gradient solar pond in malaysia / nuraida ‘aadilia baharin ...[et al.]
publisher Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM)
publishDate 2017
url http://ir.uitm.edu.my/id/eprint/39350/1/39350.pdf
http://ir.uitm.edu.my/id/eprint/39350/
_version_ 1687396768600293376
score 13.188404