Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap

The type of liquid membrane used in this work is the combination of bulk liquid membrane and emulsion liquid membrane operating in continuous mode. The existing method in of copper extraction such as solvent extraction, adsorption and chemical precipitation require additional step for removal and re...

Full description

Saved in:
Bibliographic Details
Main Author: Asap, Anne Mitchelle
Format: Student Project
Language:English
Published: 2017
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/38091/1/38091.pdf
http://ir.uitm.edu.my/id/eprint/38091/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.38091
record_format eprints
spelling my.uitm.ir.380912020-12-09T08:05:57Z http://ir.uitm.edu.my/id/eprint/38091/ Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap Asap, Anne Mitchelle Extraction (Chemistry) Chemical engineering Special processes and operations Extraction The type of liquid membrane used in this work is the combination of bulk liquid membrane and emulsion liquid membrane operating in continuous mode. The existing method in of copper extraction such as solvent extraction, adsorption and chemical precipitation require additional step for removal and recovery of Cu(II). This drawback is overcome by using liquid membrane separation technique. The objective of this study is to remove and recover Cu(II) using liquid membrane. The feed phase is a real industrial wastewater that contain high amount of copper ions. The organic phase consist of waste cooking oil loaded with tributylphosphate (TBP) and di-2- ethylhexylphosphate (D2EHPA) and sulfuric acid as stripping phase. The parameter is feed flow rate at 3.79 L/hr, membrane flow rate at 2.73 1/hr and stripping phase at stagnant. The percent of extraction is evaluate at different reaction time and analyzed using inductive coupled plasma optical emission spectrometer (ICP-OES). The percent of extraction of Cu(II) is 44.22% at reaction time of 210 minute. 2017 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/38091/1/38091.pdf Asap, Anne Mitchelle (2017) Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap. [Student Project]
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Extraction (Chemistry)
Chemical engineering
Special processes and operations
Extraction
spellingShingle Extraction (Chemistry)
Chemical engineering
Special processes and operations
Extraction
Asap, Anne Mitchelle
Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap
description The type of liquid membrane used in this work is the combination of bulk liquid membrane and emulsion liquid membrane operating in continuous mode. The existing method in of copper extraction such as solvent extraction, adsorption and chemical precipitation require additional step for removal and recovery of Cu(II). This drawback is overcome by using liquid membrane separation technique. The objective of this study is to remove and recover Cu(II) using liquid membrane. The feed phase is a real industrial wastewater that contain high amount of copper ions. The organic phase consist of waste cooking oil loaded with tributylphosphate (TBP) and di-2- ethylhexylphosphate (D2EHPA) and sulfuric acid as stripping phase. The parameter is feed flow rate at 3.79 L/hr, membrane flow rate at 2.73 1/hr and stripping phase at stagnant. The percent of extraction is evaluate at different reaction time and analyzed using inductive coupled plasma optical emission spectrometer (ICP-OES). The percent of extraction of Cu(II) is 44.22% at reaction time of 210 minute.
format Student Project
author Asap, Anne Mitchelle
author_facet Asap, Anne Mitchelle
author_sort Asap, Anne Mitchelle
title Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap
title_short Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap
title_full Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap
title_fullStr Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap
title_full_unstemmed Extraction and stripping of Cu(ii) ions from real industrial efffluent by continous liquid membrane / Anne Mitchelle Asap
title_sort extraction and stripping of cu(ii) ions from real industrial efffluent by continous liquid membrane / anne mitchelle asap
publishDate 2017
url http://ir.uitm.edu.my/id/eprint/38091/1/38091.pdf
http://ir.uitm.edu.my/id/eprint/38091/
_version_ 1685651574363258880
score 13.18916