Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya

Energy efficiency can be achieved through reducing the loss of the power by using an adequate amount of power in an electrical distribution system. In this thesis, the energy efficiency is analysed based on an electrical distribution system along with the implementation of the Conservative Voltage R...

Full description

Saved in:
Bibliographic Details
Main Author: Yahya, Mohd Ainor
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/37158/1/37158.pdf
https://ir.uitm.edu.my/id/eprint/37158/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.37158
record_format eprints
spelling my.uitm.ir.371582022-09-15T09:01:57Z https://ir.uitm.edu.my/id/eprint/37158/ Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya Yahya, Mohd Ainor Indexes (General) Energy consumption TK Electrical engineering. Electronics. Nuclear engineering Energy efficiency can be achieved through reducing the loss of the power by using an adequate amount of power in an electrical distribution system. In this thesis, the energy efficiency is analysed based on an electrical distribution system along with the implementation of the Conservative Voltage Reduction (CVR), and the Optimal Capacitor Placement and Sizing (OCPS). In order to determine optimal location and sizing of the capacitors, Ant Colony Optimization (ACO) is implemented. The capacitors will ameliorate the energy efficiency through energy consumption and power loss minimization. Prior the ACO is implemented to solve OCPS, specific number of busbars is allocated. The Power-Loss-Index (PLI) is performed to achieve the pre-selection of busbar. Three variables will represent the objectives and fitness of the proposed optimization technique, which are, the total cost of power losses, energy consumption and capacitor installation. The parameters that are considered as the proposed optimization technique constraints are; the voltage magnitude limit, Total Harmonic Distortion (THD) limit, power factor limit and capacitor size limit. Conservative Voltage Reduction (CVR) is used to gain further enhancement of the energy efficiency. This is achieved through changing the transformer tap setting in order to lower and then retain the voltage magnitude at a specific level whilst ensuring the stability of the electrical distribution system. In this study, MATLAB® is used as a platform to implement the proposed methods. These techniques will firstly transfer the information, execute the three-phase unbalanced load flow solution and retrieve. Then it will collect the results or data from the three-phase unbalanced electrical distribution systems which are modeled in the SIMULINK® toolbox. The evaluation and the effectiveness of the conducted methods, in order to improve the energy efficiency, are verified through several case studies. The findings are collected from two test systems, IEEE 13-bus unbalanced electrical distribution system and the pragmatic electrical distribution system model of Sultan Salahuddin Abdul Aziz Shah (SSAAS) building in Shah Alam, Selangor. Finally, our proposed methodology has shown ability to reduce the cost utility bills of SSAAS building. Particularly, our methodology managed to reduce the cost of maximum demand in utility bills. 2018 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/37158/1/37158.pdf Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya. (2018) Masters thesis, thesis, Universiti Teknologi MARA (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Indexes (General)
Energy consumption
TK Electrical engineering. Electronics. Nuclear engineering
spellingShingle Indexes (General)
Energy consumption
TK Electrical engineering. Electronics. Nuclear engineering
Yahya, Mohd Ainor
Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya
description Energy efficiency can be achieved through reducing the loss of the power by using an adequate amount of power in an electrical distribution system. In this thesis, the energy efficiency is analysed based on an electrical distribution system along with the implementation of the Conservative Voltage Reduction (CVR), and the Optimal Capacitor Placement and Sizing (OCPS). In order to determine optimal location and sizing of the capacitors, Ant Colony Optimization (ACO) is implemented. The capacitors will ameliorate the energy efficiency through energy consumption and power loss minimization. Prior the ACO is implemented to solve OCPS, specific number of busbars is allocated. The Power-Loss-Index (PLI) is performed to achieve the pre-selection of busbar. Three variables will represent the objectives and fitness of the proposed optimization technique, which are, the total cost of power losses, energy consumption and capacitor installation. The parameters that are considered as the proposed optimization technique constraints are; the voltage magnitude limit, Total Harmonic Distortion (THD) limit, power factor limit and capacitor size limit. Conservative Voltage Reduction (CVR) is used to gain further enhancement of the energy efficiency. This is achieved through changing the transformer tap setting in order to lower and then retain the voltage magnitude at a specific level whilst ensuring the stability of the electrical distribution system. In this study, MATLAB® is used as a platform to implement the proposed methods. These techniques will firstly transfer the information, execute the three-phase unbalanced load flow solution and retrieve. Then it will collect the results or data from the three-phase unbalanced electrical distribution systems which are modeled in the SIMULINK® toolbox. The evaluation and the effectiveness of the conducted methods, in order to improve the energy efficiency, are verified through several case studies. The findings are collected from two test systems, IEEE 13-bus unbalanced electrical distribution system and the pragmatic electrical distribution system model of Sultan Salahuddin Abdul Aziz Shah (SSAAS) building in Shah Alam, Selangor. Finally, our proposed methodology has shown ability to reduce the cost utility bills of SSAAS building. Particularly, our methodology managed to reduce the cost of maximum demand in utility bills.
format Thesis
author Yahya, Mohd Ainor
author_facet Yahya, Mohd Ainor
author_sort Yahya, Mohd Ainor
title Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya
title_short Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya
title_full Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya
title_fullStr Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya
title_full_unstemmed Energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / Mohd Ainor Yahya
title_sort energy efficiency of an unbalanced distribution system based on the conservative voltage reduction with optimal placement and sizing of capacitor using ant colony optimization technique / mohd ainor yahya
publishDate 2018
url https://ir.uitm.edu.my/id/eprint/37158/1/37158.pdf
https://ir.uitm.edu.my/id/eprint/37158/
_version_ 1744357186736226304
score 13.160551