Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.]
This paper presents the comparative performances of PID controller with several tuning rules that includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load that was based on real time implementation. The characteristic of water temperature of hydro distillation process have been mode...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam
2017
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/29588/1/29588.pdf http://ir.uitm.edu.my/id/eprint/29588/ https://jeesr.uitm.edu.my/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.29588 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.295882020-04-17T13:41:07Z http://ir.uitm.edu.my/id/eprint/29588/ Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.] Mohammad, Nurul Nadia Marzaki, Hezri Azman, Ahmad Aftas Adnan, Ramli Tajuddin, Saiful Nizam Rahiman, Mohd Hezri Fazalul Devices for production of electricity by direct energy conversion This paper presents the comparative performances of PID controller with several tuning rules that includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load that was based on real time implementation. The characteristic of water temperature of hydro distillation process have been modelled by obtaining First Order Plus Dead Time (FOPDT). In this study, a setpoint was set up to 80°C to evaluate those tuning rules in term of transient responses such as settling time, rise time and percentage of overshoot. Moreover, another performance criteria in term of energy consumption have been evaluated by using integral control signal. The result shows that PID controller with Cohen Coon tuning gives the best performances for transient analyses and also gives lower energy consumption compared to other tuning rules Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam 2017-06 Article PeerReviewed text en http://ir.uitm.edu.my/id/eprint/29588/1/29588.pdf Mohammad, Nurul Nadia and Marzaki, Hezri and Azman, Ahmad Aftas and Adnan, Ramli and Tajuddin, Saiful Nizam and Rahiman, Mohd Hezri Fazalul (2017) Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.]. Journal of Electrical and Electronic Systems Research (JEESR), 10. ISSN 1985-5389 https://jeesr.uitm.edu.my/ |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Devices for production of electricity by direct energy conversion |
spellingShingle |
Devices for production of electricity by direct energy conversion Mohammad, Nurul Nadia Marzaki, Hezri Azman, Ahmad Aftas Adnan, Ramli Tajuddin, Saiful Nizam Rahiman, Mohd Hezri Fazalul Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.] |
description |
This paper presents the comparative performances of PID controller with several tuning rules that includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load that was based on real time implementation. The characteristic of water temperature of hydro distillation process have been modelled by obtaining First Order Plus Dead Time (FOPDT). In this study, a setpoint was set up to 80°C to evaluate those tuning rules in term of transient responses such as settling time, rise time and percentage of overshoot. Moreover, another performance criteria in term of energy consumption have been evaluated by using integral control signal. The result shows that PID controller with Cohen Coon tuning gives the best performances for transient analyses and also gives lower energy consumption compared to other tuning rules |
format |
Article |
author |
Mohammad, Nurul Nadia Marzaki, Hezri Azman, Ahmad Aftas Adnan, Ramli Tajuddin, Saiful Nizam Rahiman, Mohd Hezri Fazalul |
author_facet |
Mohammad, Nurul Nadia Marzaki, Hezri Azman, Ahmad Aftas Adnan, Ramli Tajuddin, Saiful Nizam Rahiman, Mohd Hezri Fazalul |
author_sort |
Mohammad, Nurul Nadia |
title |
Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.] |
title_short |
Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.] |
title_full |
Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.] |
title_fullStr |
Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.] |
title_full_unstemmed |
Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad … [et al.] |
title_sort |
evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / nurul nadia mohammad … [et al.] |
publisher |
Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam |
publishDate |
2017 |
url |
http://ir.uitm.edu.my/id/eprint/29588/1/29588.pdf http://ir.uitm.edu.my/id/eprint/29588/ https://jeesr.uitm.edu.my/ |
_version_ |
1685650538929061888 |
score |
13.18916 |