EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa

This thesis introduces new methods in analyzing Electroencephalogram (EEG) signal by utilizing EEG spectrogram image and image processing texture analysis called Gray level Co-occurrence Matrices (GLCM). The methods attempt to apply in balanced brain and Intelligence Quotient (IQ) applications. The...

Full description

Saved in:
Bibliographic Details
Main Author: Mustafa, Mahfuzah
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/27796/1/TP_MAHFUZAH%20MUSTAFA%20EE%2014_5.pdf
http://ir.uitm.edu.my/id/eprint/27796/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.27796
record_format eprints
spelling my.uitm.ir.277962020-01-30T08:37:09Z http://ir.uitm.edu.my/id/eprint/27796/ EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa Mustafa, Mahfuzah Electronics Pattern recognition systems This thesis introduces new methods in analyzing Electroencephalogram (EEG) signal by utilizing EEG spectrogram image and image processing texture analysis called Gray level Co-occurrence Matrices (GLCM). The methods attempt to apply in balanced brain and Intelligence Quotient (IQ) applications. The relationship between balanced brain and IQ application also proposed in this thesis. Collection of EEG signals were recorded from 101 volunteers. EEG signals recorded for the balanced brain application contain closed eyes state meanwhile for the IQ application contains closed eyes and opened eyes state. Before processing the information from the EEG signals, signal preprocessing is done to remove artefacts and unwanted signal frequencies. A time frequency based technique called EEG spectrogram image was used to generate an image from EEG signal. The spectrogram image was produced for each EEG signals sub-band frequency Delta, Theta, Alpha and Beta. The GLCM texture analysis derives features from EEG spectrogram image. Then, Principal Component Analysis (PCA) was applied to reduce the results and selected principal components features were used as inputs to the classifier. Two classifiers involved in this experiment are K-Nearest Neighbor (KNN) and Artificial Neural Network (ANN). The number of training and testing ratio is assessed at 70 to 30 and 80 to 20 to find the best model based on percentage of accuracy, sensitivity, specificity as well as Mean Squared Error (MSE). The relationship pattern of balanced brain and IQ application were observed via histogram and then Scatterplot. The strength and significant of the relationship was evaluated by using Pearson correlation test. The percentage of correctness classification for balanced brain application is 90% and MSE 0.1. The sensitivity and specificity of this application is ranging from 66.67% to 100%. The accuracy for IQ application is 94.44% and MSE 0.0752. Meanwhile, the sensitivity and specificity of this application is ranging from 0% to 100%. The relationship between balanced brain and IQ achieved with positive and strong correlation with r ranging between 0.860 to 1.000 and p < 0.05 for some cases. The experiments reported in this thesis showed that the proposed technique were highly successful in indexing the balanced brain level and IQ. 2014 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/27796/1/TP_MAHFUZAH%20MUSTAFA%20EE%2014_5.pdf Mustafa, Mahfuzah (2014) EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa. PhD thesis, Universiti Teknologi MARA.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Electronics
Pattern recognition systems
spellingShingle Electronics
Pattern recognition systems
Mustafa, Mahfuzah
EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa
description This thesis introduces new methods in analyzing Electroencephalogram (EEG) signal by utilizing EEG spectrogram image and image processing texture analysis called Gray level Co-occurrence Matrices (GLCM). The methods attempt to apply in balanced brain and Intelligence Quotient (IQ) applications. The relationship between balanced brain and IQ application also proposed in this thesis. Collection of EEG signals were recorded from 101 volunteers. EEG signals recorded for the balanced brain application contain closed eyes state meanwhile for the IQ application contains closed eyes and opened eyes state. Before processing the information from the EEG signals, signal preprocessing is done to remove artefacts and unwanted signal frequencies. A time frequency based technique called EEG spectrogram image was used to generate an image from EEG signal. The spectrogram image was produced for each EEG signals sub-band frequency Delta, Theta, Alpha and Beta. The GLCM texture analysis derives features from EEG spectrogram image. Then, Principal Component Analysis (PCA) was applied to reduce the results and selected principal components features were used as inputs to the classifier. Two classifiers involved in this experiment are K-Nearest Neighbor (KNN) and Artificial Neural Network (ANN). The number of training and testing ratio is assessed at 70 to 30 and 80 to 20 to find the best model based on percentage of accuracy, sensitivity, specificity as well as Mean Squared Error (MSE). The relationship pattern of balanced brain and IQ application were observed via histogram and then Scatterplot. The strength and significant of the relationship was evaluated by using Pearson correlation test. The percentage of correctness classification for balanced brain application is 90% and MSE 0.1. The sensitivity and specificity of this application is ranging from 66.67% to 100%. The accuracy for IQ application is 94.44% and MSE 0.0752. Meanwhile, the sensitivity and specificity of this application is ranging from 0% to 100%. The relationship between balanced brain and IQ achieved with positive and strong correlation with r ranging between 0.860 to 1.000 and p < 0.05 for some cases. The experiments reported in this thesis showed that the proposed technique were highly successful in indexing the balanced brain level and IQ.
format Thesis
author Mustafa, Mahfuzah
author_facet Mustafa, Mahfuzah
author_sort Mustafa, Mahfuzah
title EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa
title_short EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa
title_full EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa
title_fullStr EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa
title_full_unstemmed EEG sub-band frequency analysis of spectrogram image for balanced brainwave and IQ applications / Mahfuzah Mustafa
title_sort eeg sub-band frequency analysis of spectrogram image for balanced brainwave and iq applications / mahfuzah mustafa
publishDate 2014
url http://ir.uitm.edu.my/id/eprint/27796/1/TP_MAHFUZAH%20MUSTAFA%20EE%2014_5.pdf
http://ir.uitm.edu.my/id/eprint/27796/
_version_ 1685650322840616960
score 13.15806