Sizing accuracy of lack of side wall fusion on single v-butt joint welds using ultrasonic back tip diffraction technique / Nurhayati Nadhirah Muhamad
This purpose of study is to compare the performance of conventional Ultrasonic Testing (UT) with Back Tip Diffraction technique on Phased Array Ultrasonic Testing (PAUT) in determining the size of Lack of Sidewall Fusion (LOSWF) defect on single V-butt joint welds. The instrument used for both me...
Saved in:
Main Author: | |
---|---|
Format: | Student Project |
Language: | English |
Published: |
Faculty of Applied Sciences
2017
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/23684/1/PPb_NURHAYATI%20NADHIRAH%20MUHAMAD%20AS%20C%2017_5.PDF http://ir.uitm.edu.my/id/eprint/23684/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.23684 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.236842019-11-18T04:20:42Z http://ir.uitm.edu.my/id/eprint/23684/ Sizing accuracy of lack of side wall fusion on single v-butt joint welds using ultrasonic back tip diffraction technique / Nurhayati Nadhirah Muhamad Muhamad, Nurhayati Nadhirah Applications of electronics This purpose of study is to compare the performance of conventional Ultrasonic Testing (UT) with Back Tip Diffraction technique on Phased Array Ultrasonic Testing (PAUT) in determining the size of Lack of Sidewall Fusion (LOSWF) defect on single V-butt joint welds. The instrument used for both methods is OmniScan MX2, equipped with 5L64 probe and rexolite angle wedge. The frequency and beam angle is set at 5MHz and 45°, 60° and 70°. Three welded carbon steel for this study are PL 14971, PL 14962 and PL 14960, each has designated LOSWF defect varied in height and length. The sizing technique applied is 6dB drop technique. The dimension obtained then compared with a reference data and the relative difference between the two acquired. For PL 14971, the relative error for conventional UT and PAUT with Back Tip Diffraction inspection in obtaining LOSWF length is 0% and 6.67% while 373% and 20.4% for its height. For PL 14962 and PL 14960, the length relative difference for is 7.14% and 10.7% using conventional UT and 10.7% and 32.1% using PAUT. Their height relative difference using conventional method is 21.4% and 80.6%. The diffracted signal from PL 14962 and PL 14960 were too faint to acquire their height. Therefore, this study proved that conventional UT method is suitable to obtain LOSWF length and height for specimen that has any thickness. PAUT with Back Tip Diffraction technique, however, is not suitable to determine defect height for specimen that is 8mm or thinner than that. Faculty of Applied Sciences 2017 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/23684/1/PPb_NURHAYATI%20NADHIRAH%20MUHAMAD%20AS%20C%2017_5.PDF Muhamad, Nurhayati Nadhirah (2017) Sizing accuracy of lack of side wall fusion on single v-butt joint welds using ultrasonic back tip diffraction technique / Nurhayati Nadhirah Muhamad. [Student Project] (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Applications of electronics |
spellingShingle |
Applications of electronics Muhamad, Nurhayati Nadhirah Sizing accuracy of lack of side wall fusion on single v-butt joint welds using ultrasonic back tip diffraction technique / Nurhayati Nadhirah Muhamad |
description |
This purpose of study is to compare the performance of conventional Ultrasonic
Testing (UT) with Back Tip Diffraction technique on Phased Array Ultrasonic
Testing (PAUT) in determining the size of Lack of Sidewall Fusion (LOSWF)
defect on single V-butt joint welds. The instrument used for both methods is
OmniScan MX2, equipped with 5L64 probe and rexolite angle wedge. The
frequency and beam angle is set at 5MHz and 45°, 60° and 70°. Three welded
carbon steel for this study are PL 14971, PL 14962 and PL 14960, each has
designated LOSWF defect varied in height and length. The sizing technique
applied is 6dB drop technique. The dimension obtained then compared with a
reference data and the relative difference between the two acquired. For PL
14971, the relative error for conventional UT and PAUT with Back Tip
Diffraction inspection in obtaining LOSWF length is 0% and 6.67% while 373%
and 20.4% for its height. For PL 14962 and PL 14960, the length relative
difference for is 7.14% and 10.7% using conventional UT and 10.7% and 32.1%
using PAUT. Their height relative difference using conventional method is 21.4%
and 80.6%. The diffracted signal from PL 14962 and PL 14960 were too faint to
acquire their height. Therefore, this study proved that conventional UT method is
suitable to obtain LOSWF length and height for specimen that has any thickness.
PAUT with Back Tip Diffraction technique, however, is not suitable to determine
defect height for specimen that is 8mm or thinner than that. |
format |
Student Project |
author |
Muhamad, Nurhayati Nadhirah |
author_facet |
Muhamad, Nurhayati Nadhirah |
author_sort |
Muhamad, Nurhayati Nadhirah |
title |
Sizing accuracy of lack of side wall fusion on
single v-butt joint welds using ultrasonic back tip
diffraction technique / Nurhayati Nadhirah Muhamad |
title_short |
Sizing accuracy of lack of side wall fusion on
single v-butt joint welds using ultrasonic back tip
diffraction technique / Nurhayati Nadhirah Muhamad |
title_full |
Sizing accuracy of lack of side wall fusion on
single v-butt joint welds using ultrasonic back tip
diffraction technique / Nurhayati Nadhirah Muhamad |
title_fullStr |
Sizing accuracy of lack of side wall fusion on
single v-butt joint welds using ultrasonic back tip
diffraction technique / Nurhayati Nadhirah Muhamad |
title_full_unstemmed |
Sizing accuracy of lack of side wall fusion on
single v-butt joint welds using ultrasonic back tip
diffraction technique / Nurhayati Nadhirah Muhamad |
title_sort |
sizing accuracy of lack of side wall fusion on
single v-butt joint welds using ultrasonic back tip
diffraction technique / nurhayati nadhirah muhamad |
publisher |
Faculty of Applied Sciences |
publishDate |
2017 |
url |
http://ir.uitm.edu.my/id/eprint/23684/1/PPb_NURHAYATI%20NADHIRAH%20MUHAMAD%20AS%20C%2017_5.PDF http://ir.uitm.edu.my/id/eprint/23684/ |
_version_ |
1685649764101652480 |
score |
13.211869 |