Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail

Sixty percent of Malaysians prefer to stay in linked houses for reasons of location, space and aesthetic. Most of these houses are installed with mechanical cooling and air circulating fans for thermal comfort instead of a more passive means. There are less demand for courtyard linked houses althoug...

Full description

Saved in:
Bibliographic Details
Main Author: Ismail, Mohd Riza
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/18936/1/TP_MOHD%20RIZA%20ISMAIL%20AP%2016_5.pdf
http://ir.uitm.edu.my/id/eprint/18936/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.18936
record_format eprints
spelling my.uitm.ir.189362018-01-29T01:49:08Z http://ir.uitm.edu.my/id/eprint/18936/ Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail Ismail, Mohd Riza Architectural drawing and design Architectural decoration Sixty percent of Malaysians prefer to stay in linked houses for reasons of location, space and aesthetic. Most of these houses are installed with mechanical cooling and air circulating fans for thermal comfort instead of a more passive means. There are less demand for courtyard linked houses although the courtyard could hypothetically to be the answer for a passive cooling design strategy. Hence, the aim of this research is to explore the possibilities of enhancing indoor thermal comfort condition by determining the effectiveness of courtyard as a passive cooling building element. The objectives of this thesis are: i) to study the types of courtyard configuration in existing linked houses; ii) to investigate the environmental condition of the courtyard and its effect to the indoor thermal comfort; iii) to explore the importance of courtyard configuration in providing good natural ventilation and iv) to determine the best courtyard configuration that create best indoor thermal comfort of a linked house. This study investigated two similar urban linked houses (with and without internal courtyard) in terms of size and specifications in Shah Alam and Klang. Data based on two days of measurements and observations at both houses for outdoor, indoor temperature, relative humidity and air velocity revealed that the indoor thermal conditions for both houses exceeded the thermal comfort zone recommended by Givoni's Bio-Climatic chart and ASHRAE. However, through comparative analysis, the house with internal centre courtyard produced better results and maintained a more comfortable indoor condition due to its horizontal and vertical natural cross ventilation which occurred during the day time and night time. Further predictive investigations on the courtyard linked house, based on CFD simulations using Flovent 7.2 and AnSys were conducted. Three variations of design models were studied namely enlarged courtyard area, increased courtyard walls height and enlarged openings at the front and rear. Diurnal simulations concluded that the increased of courtyard surrounding wall height and enlarged openings at front and rear options were the most effective, whereas the enlarged courtyard area (footprint) type were less effective, regardless of which operation mode were applied. Hence, linked houses with courtyards are proven to be beneficial to the occupants by providing passive cooling through natural ventilation. 2016 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/18936/1/TP_MOHD%20RIZA%20ISMAIL%20AP%2016_5.pdf Ismail, Mohd Riza (2016) Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail. PhD thesis, Universiti Teknologi MARA.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Architectural drawing and design
Architectural decoration
spellingShingle Architectural drawing and design
Architectural decoration
Ismail, Mohd Riza
Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail
description Sixty percent of Malaysians prefer to stay in linked houses for reasons of location, space and aesthetic. Most of these houses are installed with mechanical cooling and air circulating fans for thermal comfort instead of a more passive means. There are less demand for courtyard linked houses although the courtyard could hypothetically to be the answer for a passive cooling design strategy. Hence, the aim of this research is to explore the possibilities of enhancing indoor thermal comfort condition by determining the effectiveness of courtyard as a passive cooling building element. The objectives of this thesis are: i) to study the types of courtyard configuration in existing linked houses; ii) to investigate the environmental condition of the courtyard and its effect to the indoor thermal comfort; iii) to explore the importance of courtyard configuration in providing good natural ventilation and iv) to determine the best courtyard configuration that create best indoor thermal comfort of a linked house. This study investigated two similar urban linked houses (with and without internal courtyard) in terms of size and specifications in Shah Alam and Klang. Data based on two days of measurements and observations at both houses for outdoor, indoor temperature, relative humidity and air velocity revealed that the indoor thermal conditions for both houses exceeded the thermal comfort zone recommended by Givoni's Bio-Climatic chart and ASHRAE. However, through comparative analysis, the house with internal centre courtyard produced better results and maintained a more comfortable indoor condition due to its horizontal and vertical natural cross ventilation which occurred during the day time and night time. Further predictive investigations on the courtyard linked house, based on CFD simulations using Flovent 7.2 and AnSys were conducted. Three variations of design models were studied namely enlarged courtyard area, increased courtyard walls height and enlarged openings at the front and rear. Diurnal simulations concluded that the increased of courtyard surrounding wall height and enlarged openings at front and rear options were the most effective, whereas the enlarged courtyard area (footprint) type were less effective, regardless of which operation mode were applied. Hence, linked houses with courtyards are proven to be beneficial to the occupants by providing passive cooling through natural ventilation.
format Thesis
author Ismail, Mohd Riza
author_facet Ismail, Mohd Riza
author_sort Ismail, Mohd Riza
title Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail
title_short Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail
title_full Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail
title_fullStr Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail
title_full_unstemmed Courtyard as a passive cooling design strategy in Malaysian linked houses / Mohd Riza Ismail
title_sort courtyard as a passive cooling design strategy in malaysian linked houses / mohd riza ismail
publishDate 2016
url http://ir.uitm.edu.my/id/eprint/18936/1/TP_MOHD%20RIZA%20ISMAIL%20AP%2016_5.pdf
http://ir.uitm.edu.my/id/eprint/18936/
_version_ 1685649146739949568
score 13.18916