Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor

This project was present the finite element analysis of Profiled Steel Sheet Dry Board (PSSDB) composite wall panel with window opening and different screw spacing. PSSDB system is a structural system consisting of profiled steel sheeting connected to dry board by self-tapping and self-drilling scre...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Nor, Rosniza
Format: Student Project
Language:English
Published: Faculty of Civil Engineering 2005
Online Access:http://ir.uitm.edu.my/id/eprint/18118/2/PPb_ROSNIZA%20MOHD%20NOR%20EC%2005_5.pdf
http://ir.uitm.edu.my/id/eprint/18118/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.18118
record_format eprints
spelling my.uitm.ir.181182019-02-19T08:10:23Z http://ir.uitm.edu.my/id/eprint/18118/ Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor Mohd Nor, Rosniza This project was present the finite element analysis of Profiled Steel Sheet Dry Board (PSSDB) composite wall panel with window opening and different screw spacing. PSSDB system is a structural system consisting of profiled steel sheeting connected to dry board by self-tapping and self-drilling screws. It is a composite system that can be used as load bearing component for the building, such as flooring, roofing and walling units. Finite elements analysis software called LUSAS has applied for this study. The model analyzed measurement is 3100mm wide and 3000mm high and window opening of 1200mm by 1200mm is modeled as symmetrical position. The structural behavior of PSSDB wall panels under compressive axial load with difference screw is presented and discussed. Beside that, the influence of connector spacing on the overall structural performance of the PSSDB wall panels has been described. As consequently, the connector spacing play major roles in influencing the stiffness of such composite panels was carried out. The profiled steel sheeting is the main component in resisting load on the PSSDB wall panel, while the dry board is very instrumental in delaying elastic deflections besides carrying a small portion of the load. By obtained this project using LUSAS programme, proved that the PSSDB wall panels have a good load bearing capacity and stiff when built as a wall units. Panel 200 with spacing 200 mm at each vertical panel has shows the best optimum stiffness with economical, effective and efficient. Faculty of Civil Engineering 2005 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/18118/2/PPb_ROSNIZA%20MOHD%20NOR%20EC%2005_5.pdf Mohd Nor, Rosniza (2005) Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor. [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description This project was present the finite element analysis of Profiled Steel Sheet Dry Board (PSSDB) composite wall panel with window opening and different screw spacing. PSSDB system is a structural system consisting of profiled steel sheeting connected to dry board by self-tapping and self-drilling screws. It is a composite system that can be used as load bearing component for the building, such as flooring, roofing and walling units. Finite elements analysis software called LUSAS has applied for this study. The model analyzed measurement is 3100mm wide and 3000mm high and window opening of 1200mm by 1200mm is modeled as symmetrical position. The structural behavior of PSSDB wall panels under compressive axial load with difference screw is presented and discussed. Beside that, the influence of connector spacing on the overall structural performance of the PSSDB wall panels has been described. As consequently, the connector spacing play major roles in influencing the stiffness of such composite panels was carried out. The profiled steel sheeting is the main component in resisting load on the PSSDB wall panel, while the dry board is very instrumental in delaying elastic deflections besides carrying a small portion of the load. By obtained this project using LUSAS programme, proved that the PSSDB wall panels have a good load bearing capacity and stiff when built as a wall units. Panel 200 with spacing 200 mm at each vertical panel has shows the best optimum stiffness with economical, effective and efficient.
format Student Project
author Mohd Nor, Rosniza
spellingShingle Mohd Nor, Rosniza
Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor
author_facet Mohd Nor, Rosniza
author_sort Mohd Nor, Rosniza
title Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor
title_short Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor
title_full Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor
title_fullStr Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor
title_full_unstemmed Analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / Rosniza Mohd Nor
title_sort analysis of profiled steel sheet dry board wall panel with window opening and different screw spacing. / rosniza mohd nor
publisher Faculty of Civil Engineering
publishDate 2005
url http://ir.uitm.edu.my/id/eprint/18118/2/PPb_ROSNIZA%20MOHD%20NOR%20EC%2005_5.pdf
http://ir.uitm.edu.my/id/eprint/18118/
_version_ 1685649037700628480
score 13.211869