Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana

Computed tomography (CT) is an advanced imaging modalities. Its powerful ability to assist more precise diagnosis cause it to be used widely in several countries. The risk of radiation to human health has always become a concern among researchers including Malaysia. This is due to the fact that the...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Maulana, Izza Nadia
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/15580/2/15580.pdf
https://ir.uitm.edu.my/id/eprint/15580/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.15580
record_format eprints
spelling my.uitm.ir.155802022-11-24T03:39:29Z https://ir.uitm.edu.my/id/eprint/15580/ Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana Mohd Maulana, Izza Nadia Medical education. Medical schools. Research Computed tomography (CT) is an advanced imaging modalities. Its powerful ability to assist more precise diagnosis cause it to be used widely in several countries. The risk of radiation to human health has always become a concern among researchers including Malaysia. This is due to the fact that the number of CT scanner and CT procedure in Malaysia is increasing more than 15% from 2009 to 2010. Therefore, it is expected that the number will increase year by year. The aim of this research is to study the variation of radiation dose (dose descriptors) to the patients at the hospitals involved in this research. However, this research is only focus in certain hospitals in northern region of Malaysia. The dose descriptors include weighted CT Dose Index (CTDIw), volume CT dose index (CTDIvol), dose-length product (DLP) and effective dose (E). The data had been collected by using questionnaire distributed to the hospitals. The data was analysed by using CT Expo v 1.4 in order to calculate the dose descriptors. The result showed that there are variation of dose descriptors in all hospitals and the overall result is higher than previous studies. It is hoped that every hospital can implement the guideline recommended by established bodies in order to reduce the radiation dose to the patient. 2015 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/15580/2/15580.pdf Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana. (2015) Masters thesis, thesis, Universiti Teknologi MARA. <http://terminalib.uitm.edu.my/15580.pdf>
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Medical education. Medical schools. Research
spellingShingle Medical education. Medical schools. Research
Mohd Maulana, Izza Nadia
Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana
description Computed tomography (CT) is an advanced imaging modalities. Its powerful ability to assist more precise diagnosis cause it to be used widely in several countries. The risk of radiation to human health has always become a concern among researchers including Malaysia. This is due to the fact that the number of CT scanner and CT procedure in Malaysia is increasing more than 15% from 2009 to 2010. Therefore, it is expected that the number will increase year by year. The aim of this research is to study the variation of radiation dose (dose descriptors) to the patients at the hospitals involved in this research. However, this research is only focus in certain hospitals in northern region of Malaysia. The dose descriptors include weighted CT Dose Index (CTDIw), volume CT dose index (CTDIvol), dose-length product (DLP) and effective dose (E). The data had been collected by using questionnaire distributed to the hospitals. The data was analysed by using CT Expo v 1.4 in order to calculate the dose descriptors. The result showed that there are variation of dose descriptors in all hospitals and the overall result is higher than previous studies. It is hoped that every hospital can implement the guideline recommended by established bodies in order to reduce the radiation dose to the patient.
format Thesis
author Mohd Maulana, Izza Nadia
author_facet Mohd Maulana, Izza Nadia
author_sort Mohd Maulana, Izza Nadia
title Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana
title_short Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana
title_full Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana
title_fullStr Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana
title_full_unstemmed Abdominal computed tomography radiation dose for six hospitals at northern region in Malaysia / Izza Nadia Mohd Maulana
title_sort abdominal computed tomography radiation dose for six hospitals at northern region in malaysia / izza nadia mohd maulana
publishDate 2015
url https://ir.uitm.edu.my/id/eprint/15580/2/15580.pdf
https://ir.uitm.edu.my/id/eprint/15580/
_version_ 1751539757242908672
score 13.18916