The development of heart rate monitor using finger detector / Hanif Baki
This paper presents the development of heart rate monitoring using finger detector. The portable hardware consists of circuit design for heart rate is developed as a medical tool to measure the cardiovascular pulse wave that is found throughout the human body. An ordinary infrared LED / photodetecto...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2006
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/102921/1/102921.pdf https://ir.uitm.edu.my/id/eprint/102921/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.102921 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.1029212024-12-02T03:19:34Z https://ir.uitm.edu.my/id/eprint/102921/ The development of heart rate monitor using finger detector / Hanif Baki Baki, Hanif Diseases of the circulatory (Cardiovascular) system Detectors. Sensors. Sensor networks This paper presents the development of heart rate monitoring using finger detector. The portable hardware consists of circuit design for heart rate is developed as a medical tool to measure the cardiovascular pulse wave that is found throughout the human body. An ordinary infrared LED / photodetector can sense this rhythmic change as small as but detectable variation in skin contrast. When gently held against the skin (too much pressure will flatten the surface capillaries and suppress the pulsation effect), some of the radiation from LED, reflects back into photodetector. Photodetector produces an analogue pulse for every 1% change in skin reflectance. This logarithmic relationship is constant over many orders of magnitude of photodetector. Consequently, reliable circuit operation is possible despite wide variations n skin contrast and light level. Oscilloscope is used to monitor the heart rate signal. 2006 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/102921/1/102921.pdf The development of heart rate monitor using finger detector / Hanif Baki. (2006) Degree thesis, thesis, Universiti Teknologi MARA (UiTM). <http://terminalib.uitm.edu.my/102921.pdf> |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Diseases of the circulatory (Cardiovascular) system Detectors. Sensors. Sensor networks |
spellingShingle |
Diseases of the circulatory (Cardiovascular) system Detectors. Sensors. Sensor networks Baki, Hanif The development of heart rate monitor using finger detector / Hanif Baki |
description |
This paper presents the development of heart rate monitoring using finger detector. The portable hardware consists of circuit design for heart rate is developed as a medical tool to measure the cardiovascular pulse wave that is found throughout the human body. An ordinary infrared LED / photodetector can sense this rhythmic change as small as but detectable variation in skin contrast. When gently held against the skin (too much pressure will flatten the surface capillaries and suppress the pulsation effect), some of the radiation from LED, reflects back into photodetector. Photodetector produces an analogue pulse for every 1% change in skin reflectance. This logarithmic relationship is constant over many orders of magnitude of photodetector. Consequently, reliable circuit operation is possible despite wide variations n skin contrast and light level. Oscilloscope is used to monitor the heart rate signal. |
format |
Thesis |
author |
Baki, Hanif |
author_facet |
Baki, Hanif |
author_sort |
Baki, Hanif |
title |
The development of heart rate monitor using finger detector / Hanif Baki |
title_short |
The development of heart rate monitor using finger detector / Hanif Baki |
title_full |
The development of heart rate monitor using finger detector / Hanif Baki |
title_fullStr |
The development of heart rate monitor using finger detector / Hanif Baki |
title_full_unstemmed |
The development of heart rate monitor using finger detector / Hanif Baki |
title_sort |
development of heart rate monitor using finger detector / hanif baki |
publishDate |
2006 |
url |
https://ir.uitm.edu.my/id/eprint/102921/1/102921.pdf https://ir.uitm.edu.my/id/eprint/102921/ |
_version_ |
1817847300411621376 |
score |
13.222552 |