Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
PLOS
2023
|
Subjects: | |
Online Access: | http://eprints.sunway.edu.my/2254/1/32.pdf http://eprints.sunway.edu.my/2254/ https://doi.org/10.1371/journal.pone.0280765 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.sunway.eprints.2254 |
---|---|
record_format |
eprints |
spelling |
my.sunway.eprints.22542023-06-16T03:13:39Z http://eprints.sunway.edu.my/2254/ Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method Entezam, Amir Fielding, Andrew Bradley, D.A. * Fontanarosa, Davide QA Mathematics RC Internal medicine Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research. PLOS 2023-02-02 Article PeerReviewed text en cc_by_4 http://eprints.sunway.edu.my/2254/1/32.pdf Entezam, Amir and Fielding, Andrew and Bradley, D.A. * and Fontanarosa, Davide (2023) Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method. PLOS ONE, 18 (2). ISSN 1932-6203 https://doi.org/10.1371/journal.pone.0280765 10.1371/journal.pone.0280765 |
institution |
Sunway University |
building |
Sunway Campus Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Sunway University |
content_source |
Sunway Institutional Repository |
url_provider |
http://eprints.sunway.edu.my/ |
language |
English |
topic |
QA Mathematics RC Internal medicine |
spellingShingle |
QA Mathematics RC Internal medicine Entezam, Amir Fielding, Andrew Bradley, D.A. * Fontanarosa, Davide Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method |
description |
Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered
dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research. |
format |
Article |
author |
Entezam, Amir Fielding, Andrew Bradley, D.A. * Fontanarosa, Davide |
author_facet |
Entezam, Amir Fielding, Andrew Bradley, D.A. * Fontanarosa, Davide |
author_sort |
Entezam, Amir |
title |
Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method |
title_short |
Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method |
title_full |
Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method |
title_fullStr |
Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method |
title_full_unstemmed |
Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method |
title_sort |
absorbed dose calculation for a realistic ct-derived mouse phantom irradiated with a standard cs-137 cell irradiator using a monte carlo method |
publisher |
PLOS |
publishDate |
2023 |
url |
http://eprints.sunway.edu.my/2254/1/32.pdf http://eprints.sunway.edu.my/2254/ https://doi.org/10.1371/journal.pone.0280765 |
_version_ |
1769846266148159488 |
score |
13.209306 |