GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery

Noting an increase in demand for procedures involving clinical radiosurgery we seek to develop a high spatial resolution thermoluminescence dosimeter (TLD) to allow conduct of in vivo dose verification measurements. An associated need is for a dynamic dose range exceeding that of the well-establishe...

Full description

Saved in:
Bibliographic Details
Main Authors: Alyahyawi, A., Dimitriadis, A., Nisbet, Andrew, Bradley, D.A. *
Format: Article
Published: Elsevier 2021
Subjects:
Online Access:http://eprints.sunway.edu.my/1582/
http://doi.org/10.1016/j.radphyschem.2020.108973
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.sunway.eprints.1582
record_format eprints
spelling my.sunway.eprints.15822021-02-15T05:20:18Z http://eprints.sunway.edu.my/1582/ GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery Alyahyawi, A. Dimitriadis, A. Nisbet, Andrew Bradley, D.A. * R895-920 Medical Physics/Medical Radiology Noting an increase in demand for procedures involving clinical radiosurgery we seek to develop a high spatial resolution thermoluminescence dosimeter (TLD) to allow conduct of in vivo dose verification measurements. An associated need is for a dynamic dose range exceeding that of the well-established LiF (Mg,Ti) phosphor TLD-100, with in particular the latter being limited in performance at the elevated doses seen in radiotherapy. The work investigates the performance of a novel GeB co-doped Flat Fibre (GeB-FF) fabricated using the modified chemical vapour deposition (MCVD) process, the hollow capillary optical fibres (COF) produced from this being collapsed down into flat fibres (FF) to create strain-related defects. This process has already been demonstrated to increase the low dose sensitivity of optical fibres, notably at diagnostic x-ray potentials, with Minimum Detectable Dose (MDD) values of down to 0.1 μGy. The intent of present work, conducted as a component of a safety audit, part of the hospital periodic radiation protection quality assurance program, has been to examine and compare the performance of the two forms of TL dosimeter, GeB-FF and TLD-100, measuring scattered radiation resulting from cranial cavity radiosurgery procedures. The dosimeters were placed on the neck, chest and pelvis of 20 patients. Using both types of dosimeter, raw dose values at each site show general accord (±3 mGy at 1 σ), covering mean doses ranging from some 10 mGy to less than 1 mGy, representing doses of <1% to < 0.1% of prescribed dose at the treatment site. GeB-FF results uncorrected for energy response show absorbed doses greater than that using TLD-100, by factors of some 1.4, 1.2 and 1.5 for the pelvis, chest and neck respectively; energy corrections have been shown elsewhere to provide for much closer agreement. Elsevier 2021-01 Article PeerReviewed Alyahyawi, A. and Dimitriadis, A. and Nisbet, Andrew and Bradley, D.A. * (2021) GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery. Radiation Physics and Chemistry, 178. p. 108973. ISSN 0969-806X http://doi.org/10.1016/j.radphyschem.2020.108973 doi:10.1016/j.radphyschem.2020.108973
institution Sunway University
building Sunway Campus Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Sunway University
content_source Sunway Institutional Repository
url_provider http://eprints.sunway.edu.my/
topic R895-920 Medical Physics/Medical Radiology
spellingShingle R895-920 Medical Physics/Medical Radiology
Alyahyawi, A.
Dimitriadis, A.
Nisbet, Andrew
Bradley, D.A. *
GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery
description Noting an increase in demand for procedures involving clinical radiosurgery we seek to develop a high spatial resolution thermoluminescence dosimeter (TLD) to allow conduct of in vivo dose verification measurements. An associated need is for a dynamic dose range exceeding that of the well-established LiF (Mg,Ti) phosphor TLD-100, with in particular the latter being limited in performance at the elevated doses seen in radiotherapy. The work investigates the performance of a novel GeB co-doped Flat Fibre (GeB-FF) fabricated using the modified chemical vapour deposition (MCVD) process, the hollow capillary optical fibres (COF) produced from this being collapsed down into flat fibres (FF) to create strain-related defects. This process has already been demonstrated to increase the low dose sensitivity of optical fibres, notably at diagnostic x-ray potentials, with Minimum Detectable Dose (MDD) values of down to 0.1 μGy. The intent of present work, conducted as a component of a safety audit, part of the hospital periodic radiation protection quality assurance program, has been to examine and compare the performance of the two forms of TL dosimeter, GeB-FF and TLD-100, measuring scattered radiation resulting from cranial cavity radiosurgery procedures. The dosimeters were placed on the neck, chest and pelvis of 20 patients. Using both types of dosimeter, raw dose values at each site show general accord (±3 mGy at 1 σ), covering mean doses ranging from some 10 mGy to less than 1 mGy, representing doses of <1% to < 0.1% of prescribed dose at the treatment site. GeB-FF results uncorrected for energy response show absorbed doses greater than that using TLD-100, by factors of some 1.4, 1.2 and 1.5 for the pelvis, chest and neck respectively; energy corrections have been shown elsewhere to provide for much closer agreement.
format Article
author Alyahyawi, A.
Dimitriadis, A.
Nisbet, Andrew
Bradley, D.A. *
author_facet Alyahyawi, A.
Dimitriadis, A.
Nisbet, Andrew
Bradley, D.A. *
author_sort Alyahyawi, A.
title GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery
title_short GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery
title_full GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery
title_fullStr GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery
title_full_unstemmed GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery
title_sort geb flat fibre tl dosimeters for in-vivo measurements in radiosurgery
publisher Elsevier
publishDate 2021
url http://eprints.sunway.edu.my/1582/
http://doi.org/10.1016/j.radphyschem.2020.108973
_version_ 1692994472567111680
score 13.18916