The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings

The paper aims to investigate and evaluate the impacts of the voids combination as a passive design feature on wind-driven ventilation performance in high-rise residential building units. It proposes a series of building models and thereon indoor ventilation performance and outlining why and how the...

Full description

Saved in:
Bibliographic Details
Main Authors: Laloui, Hamza, Abdul Majid, Noor Hanita, Sanusi, Aliyah Nur Zafirah
Format: Article
Language:English
Published: Emerald Publishing Limited 2021
Subjects:
Online Access:http://irep.iium.edu.my/91114/7/91114_The%20impacts%20of%20introducing%20voids%20combinations.pdf
http://irep.iium.edu.my/91114/
https://scholar.google.com/scholar_url?url=https://www.emerald.com/insight/content/doi/10.1108/ECAM-09-2020-0752/full/pdf%3Fcasa_token%3DoqlVivNz1EMAAAAA:1JmrmA7lynGX6YZk-eiKSf53kca2K2jW-zAviOTwRAwY1Y
https://doi.org/10.1108/ECAM-09-2020-0752
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.91114
record_format dspace
spelling my.iium.irep.911142021-07-29T00:38:22Z http://irep.iium.edu.my/91114/ The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings Laloui, Hamza Abdul Majid, Noor Hanita Sanusi, Aliyah Nur Zafirah LB3201 School architecture and equipment NA2542.35 Environmental aspect of architecture NA2542.36 Sustainable architecture TH7005 Heating and ventilation The paper aims to investigate and evaluate the impacts of the voids combination as a passive design feature on wind-driven ventilation performance in high-rise residential building units. It proposes a series of building models and thereon indoor ventilation performance and outlining why and how these building models designed with architectural design features are important. This study aims to provide a comprehensive understanding of how natural ventilation as a passive cooling strategy in living units of high-rise residential buildings can be applied through improving the provision of the architectural design feature of voids configurations. The study was carried out through field measurements experiment and the computational fluid dynamics methods. A series of numerical simulations were carried out to calculate the indoor ventilation rate inside the case studies of the generated building models based on various variables such as horizontal voids type, size and wind directions. The results indicate that the provision of a single-sided horizontal voids in building models can improve the indoor ventilation rate in units with cross ventilation mode up to 4 times, depending on wind direction and living unit location. The indoor ventilation performance in units located in models with single-sided horizontal voids is 17.54% higher than the units located in models without voids configuration. Furthermore, higher indoor ventilation performance was achieved in the case scenarios located at higher levels compared to the middle and lower levels in both horizontal voids types. This study explores the application of voids combinations for natural ventilation performance, investigates the numerical simulation results and validates field measurements experiment data using CFD simulation. Emerald Publishing Limited 2021-07-20 Article PeerReviewed application/pdf en http://irep.iium.edu.my/91114/7/91114_The%20impacts%20of%20introducing%20voids%20combinations.pdf Laloui, Hamza and Abdul Majid, Noor Hanita and Sanusi, Aliyah Nur Zafirah (2021) The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings. Engineering, Construction and Architectural Management. pp. 1-24. ISSN 0969-9988 E-ISSN 1365-232X https://scholar.google.com/scholar_url?url=https://www.emerald.com/insight/content/doi/10.1108/ECAM-09-2020-0752/full/pdf%3Fcasa_token%3DoqlVivNz1EMAAAAA:1JmrmA7lynGX6YZk-eiKSf53kca2K2jW-zAviOTwRAwY1Y https://doi.org/10.1108/ECAM-09-2020-0752
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic LB3201 School architecture and equipment
NA2542.35 Environmental aspect of architecture
NA2542.36 Sustainable architecture
TH7005 Heating and ventilation
spellingShingle LB3201 School architecture and equipment
NA2542.35 Environmental aspect of architecture
NA2542.36 Sustainable architecture
TH7005 Heating and ventilation
Laloui, Hamza
Abdul Majid, Noor Hanita
Sanusi, Aliyah Nur Zafirah
The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings
description The paper aims to investigate and evaluate the impacts of the voids combination as a passive design feature on wind-driven ventilation performance in high-rise residential building units. It proposes a series of building models and thereon indoor ventilation performance and outlining why and how these building models designed with architectural design features are important. This study aims to provide a comprehensive understanding of how natural ventilation as a passive cooling strategy in living units of high-rise residential buildings can be applied through improving the provision of the architectural design feature of voids configurations. The study was carried out through field measurements experiment and the computational fluid dynamics methods. A series of numerical simulations were carried out to calculate the indoor ventilation rate inside the case studies of the generated building models based on various variables such as horizontal voids type, size and wind directions. The results indicate that the provision of a single-sided horizontal voids in building models can improve the indoor ventilation rate in units with cross ventilation mode up to 4 times, depending on wind direction and living unit location. The indoor ventilation performance in units located in models with single-sided horizontal voids is 17.54% higher than the units located in models without voids configuration. Furthermore, higher indoor ventilation performance was achieved in the case scenarios located at higher levels compared to the middle and lower levels in both horizontal voids types. This study explores the application of voids combinations for natural ventilation performance, investigates the numerical simulation results and validates field measurements experiment data using CFD simulation.
format Article
author Laloui, Hamza
Abdul Majid, Noor Hanita
Sanusi, Aliyah Nur Zafirah
author_facet Laloui, Hamza
Abdul Majid, Noor Hanita
Sanusi, Aliyah Nur Zafirah
author_sort Laloui, Hamza
title The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings
title_short The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings
title_full The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings
title_fullStr The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings
title_full_unstemmed The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings
title_sort impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings
publisher Emerald Publishing Limited
publishDate 2021
url http://irep.iium.edu.my/91114/7/91114_The%20impacts%20of%20introducing%20voids%20combinations.pdf
http://irep.iium.edu.my/91114/
https://scholar.google.com/scholar_url?url=https://www.emerald.com/insight/content/doi/10.1108/ECAM-09-2020-0752/full/pdf%3Fcasa_token%3DoqlVivNz1EMAAAAA:1JmrmA7lynGX6YZk-eiKSf53kca2K2jW-zAviOTwRAwY1Y
https://doi.org/10.1108/ECAM-09-2020-0752
_version_ 1706956612592205824
score 13.164666