Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure

In radiography, radiation workers are responsible to protect patients and their caregivers from adverse effects of X-rays during diagnostic procedures. The X-ray examination rooms are designated as controlled areas where only authorised persons are allowed to enter. However, sometimes radiographers...

Full description

Saved in:
Bibliographic Details
Main Authors: Sayed, Inayatullah Shah, Yusri, Nurfadhilah Hanani
Format: Article
Language:English
Published: Malaysian Association of Medical Physics (MAMP) 2020
Subjects:
Online Access:http://irep.iium.edu.my/83424/1/Exposure%20Level.pdf
http://irep.iium.edu.my/83424/
http://myjms.moe.gov.my/index.php/ptm
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.83424
record_format dspace
spelling my.iium.irep.834242020-10-12T08:58:27Z http://irep.iium.edu.my/83424/ Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure Sayed, Inayatullah Shah Yusri, Nurfadhilah Hanani QC Physics In radiography, radiation workers are responsible to protect patients and their caregivers from adverse effects of X-rays during diagnostic procedures. The X-ray examination rooms are designated as controlled areas where only authorised persons are allowed to enter. However, sometimes radiographers allow next in-line patients’ and caregivers in X-ray examination room and ask them to stand behind the mobile lead shielding when exposure is on. The objectives of this study were to determine the amount of scatter radiation dose at different heights with respect to the floor in the X-ray examination room and to educate and increase the awareness of radiation workers about the scattered radiation in minimizing the unnecessary radiation dose to patient’s caregivers. Siemens Multix Top X-ray system was used. Kyoto Kagaku PBU-50 whole body phantom was scanned. The phantom (torso) was positioned for anteroposterior (AP) lumbar projection on the examination table. The nanoDot OSLDs were fixed behind the lead shielding at different heights (120, 130, 140, 150, 160 and 170 cm) with respect to the floor 2.5 meters away from the central ray of X-ray beam. The phantom was exposed using different tube voltages 68 kVp, 79 kVp and 90 kVp at a constant tube current of 32 mAs fixing a 100 cm source to image distance (SID). Scatter radiation doses measured at different heights were different for each exposure. The highest scattered radiation dose measured was 6.4 mGy at 130 cm height for 79 kVp exposure. In conclusion the measured scattered radiation doses were within the acceptable annual dose limits as recommended by NCRP 116 and ICRP 103 for patient caregiver. However, a smallest amount of radiation dose may increase the risk of cancer. Thus, the negligence must not be overlooked because it exposes the caregiver to unnecessary radiation. Malaysian Association of Medical Physics (MAMP) 2020-06 Article PeerReviewed application/pdf en http://irep.iium.edu.my/83424/1/Exposure%20Level.pdf Sayed, Inayatullah Shah and Yusri, Nurfadhilah Hanani (2020) Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure. Physics and Technology in Medicine, 1 (1). pp. 22-26. ISSN 2710-7221 E-ISSN 2710-723X http://myjms.moe.gov.my/index.php/ptm
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic QC Physics
spellingShingle QC Physics
Sayed, Inayatullah Shah
Yusri, Nurfadhilah Hanani
Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure
description In radiography, radiation workers are responsible to protect patients and their caregivers from adverse effects of X-rays during diagnostic procedures. The X-ray examination rooms are designated as controlled areas where only authorised persons are allowed to enter. However, sometimes radiographers allow next in-line patients’ and caregivers in X-ray examination room and ask them to stand behind the mobile lead shielding when exposure is on. The objectives of this study were to determine the amount of scatter radiation dose at different heights with respect to the floor in the X-ray examination room and to educate and increase the awareness of radiation workers about the scattered radiation in minimizing the unnecessary radiation dose to patient’s caregivers. Siemens Multix Top X-ray system was used. Kyoto Kagaku PBU-50 whole body phantom was scanned. The phantom (torso) was positioned for anteroposterior (AP) lumbar projection on the examination table. The nanoDot OSLDs were fixed behind the lead shielding at different heights (120, 130, 140, 150, 160 and 170 cm) with respect to the floor 2.5 meters away from the central ray of X-ray beam. The phantom was exposed using different tube voltages 68 kVp, 79 kVp and 90 kVp at a constant tube current of 32 mAs fixing a 100 cm source to image distance (SID). Scatter radiation doses measured at different heights were different for each exposure. The highest scattered radiation dose measured was 6.4 mGy at 130 cm height for 79 kVp exposure. In conclusion the measured scattered radiation doses were within the acceptable annual dose limits as recommended by NCRP 116 and ICRP 103 for patient caregiver. However, a smallest amount of radiation dose may increase the risk of cancer. Thus, the negligence must not be overlooked because it exposes the caregiver to unnecessary radiation.
format Article
author Sayed, Inayatullah Shah
Yusri, Nurfadhilah Hanani
author_facet Sayed, Inayatullah Shah
Yusri, Nurfadhilah Hanani
author_sort Sayed, Inayatullah Shah
title Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure
title_short Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure
title_full Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure
title_fullStr Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure
title_full_unstemmed Exposure level to caregivers resulting from the scattered radiation during a radiographic procedure
title_sort exposure level to caregivers resulting from the scattered radiation during a radiographic procedure
publisher Malaysian Association of Medical Physics (MAMP)
publishDate 2020
url http://irep.iium.edu.my/83424/1/Exposure%20Level.pdf
http://irep.iium.edu.my/83424/
http://myjms.moe.gov.my/index.php/ptm
_version_ 1681489290076356608
score 13.160551