The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography

The difference of lower tear meniscus height (TMH) value between invasive and non-invasive techniques is under explained. This study aims to compare the value of lower TMH between Oculus keratograph 5M (OK5M) and anterior segment digital imaging (ASDI) using slit lamp with iPhone6 video recorder att...

Full description

Saved in:
Bibliographic Details
Main Authors: Rosmadi, Nurin Izzati, Yusoff, Nur Hanisah Diyana, Hilmi, Mohd Radzi, Mohd Kamal, Khairidzan, Ithnin, Mohd. Hafidz
Format: Article
Language:English
Published: Management Science University (MSU) 2019
Subjects:
Online Access:http://irep.iium.edu.my/77600/1/77600_The%20Measurement%20of%20Lower%20Tear%20Meniscus_article_new.pdf
http://irep.iium.edu.my/77600/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.77600
record_format dspace
spelling my.iium.irep.776002020-09-14T04:55:41Z http://irep.iium.edu.my/77600/ The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography Rosmadi, Nurin Izzati Yusoff, Nur Hanisah Diyana Hilmi, Mohd Radzi Mohd Kamal, Khairidzan Ithnin, Mohd. Hafidz RE Ophthalmology The difference of lower tear meniscus height (TMH) value between invasive and non-invasive techniques is under explained. This study aims to compare the value of lower TMH between Oculus keratograph 5M (OK5M) and anterior segment digital imaging (ASDI) using slit lamp with iPhone6 video recorder attached. The totals of twenty participants with 40 eyes were involved in this cross-sectional study. Right and left eyes from an individual were considered separately. Instillation of fluorescein sodium was applied on the ASDI technique only. Three measurements of TMH were taken from each methods and average were calculated and recorded. Independent sample t-test was used to analyze the data and it was found that the mean of the TMH measurement from the ASDI (0.42 ± 0.11 mm) was higher than the mean from the OK5M (0.25 ± 0.06 mm). The comparison between two methods was significant (p < 0.05). In conclusion, this study suggested that the higher TMH in ASDI was resulted by the effect of fluorescein and together with local climate. Management Science University (MSU) 2019-12-17 Article PeerReviewed application/pdf en http://irep.iium.edu.my/77600/1/77600_The%20Measurement%20of%20Lower%20Tear%20Meniscus_article_new.pdf Rosmadi, Nurin Izzati and Yusoff, Nur Hanisah Diyana and Hilmi, Mohd Radzi and Mohd Kamal, Khairidzan and Ithnin, Mohd. Hafidz (2019) The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography. Journal of Optometry, Eye and Health Research (JOEHR), 1 (1). E-ISSN 2682-7859
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Rosmadi, Nurin Izzati
Yusoff, Nur Hanisah Diyana
Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Ithnin, Mohd. Hafidz
The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography
description The difference of lower tear meniscus height (TMH) value between invasive and non-invasive techniques is under explained. This study aims to compare the value of lower TMH between Oculus keratograph 5M (OK5M) and anterior segment digital imaging (ASDI) using slit lamp with iPhone6 video recorder attached. The totals of twenty participants with 40 eyes were involved in this cross-sectional study. Right and left eyes from an individual were considered separately. Instillation of fluorescein sodium was applied on the ASDI technique only. Three measurements of TMH were taken from each methods and average were calculated and recorded. Independent sample t-test was used to analyze the data and it was found that the mean of the TMH measurement from the ASDI (0.42 ± 0.11 mm) was higher than the mean from the OK5M (0.25 ± 0.06 mm). The comparison between two methods was significant (p < 0.05). In conclusion, this study suggested that the higher TMH in ASDI was resulted by the effect of fluorescein and together with local climate.
format Article
author Rosmadi, Nurin Izzati
Yusoff, Nur Hanisah Diyana
Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Ithnin, Mohd. Hafidz
author_facet Rosmadi, Nurin Izzati
Yusoff, Nur Hanisah Diyana
Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Ithnin, Mohd. Hafidz
author_sort Rosmadi, Nurin Izzati
title The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography
title_short The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography
title_full The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography
title_fullStr The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography
title_full_unstemmed The measurement of lower tear meniscus height using Anterior segment digital imaging and keratography
title_sort measurement of lower tear meniscus height using anterior segment digital imaging and keratography
publisher Management Science University (MSU)
publishDate 2019
url http://irep.iium.edu.my/77600/1/77600_The%20Measurement%20of%20Lower%20Tear%20Meniscus_article_new.pdf
http://irep.iium.edu.my/77600/
_version_ 1678592797572071424
score 13.160551