Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs

Contour interaction for visual acuity has been found to dissipate with imposed dioptric blur of +1.50D using standard luminance letters and bars (Simmers et al, 1999). It is unclear how dioptric blur affects visual acuity or contour interaction for letters imbedded in noise. We examined the effects...

Full description

Saved in:
Bibliographic Details
Main Authors: Waugh, Sarah, Monika, Formankiewicz, Ahmad, Norsham, Hairol, Izzuddin
Format: Article
Language:English
Published: The Association for Research in Vision and Ophthalmology, Inc. (ARVO) 2010
Subjects:
Online Access:http://irep.iium.edu.my/73671/1/Effects%20of%20dioptric%20blur%20on%20foveal%20acuity%20and%20contour%20interaction%20for%20noisy%20Cs%20_%20JOV%20_%20ARVO%20Journals.pdf
http://irep.iium.edu.my/73671/
https://jov.arvojournals.org/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.73671
record_format dspace
spelling my.iium.irep.736712019-07-29T01:28:37Z http://irep.iium.edu.my/73671/ Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs Waugh, Sarah Monika, Formankiewicz Ahmad, Norsham Hairol, Izzuddin RE Ophthalmology Contour interaction for visual acuity has been found to dissipate with imposed dioptric blur of +1.50D using standard luminance letters and bars (Simmers et al, 1999). It is unclear how dioptric blur affects visual acuity or contour interaction for letters imbedded in noise. We examined the effects of dioptric blur on luminance-modulated and contrast-modulated noise Cs with and without surrounding contours. Stimuli were constructed from random dot dynamic noise, added or multiplied to a square-wave profile. We measured foveal acuity for a square-shaped C with and without four flanking bars separated by 0 to 2 letter widths under different levels of dioptric blur (0-2D with flanks; 0-4D without). Acuity was measured using a method of constant stimuli and 4AFC paradigm for approximately equally visible luminance-modulated and contrast-modulated noisy Cs. Acuity thresholds for isolated contrast-modulated Cs are about 0.3 logMAR higher than for luminance-modulated Cs at all blur levels. The effect of increasing blur on acuity is ~0.3 logMAR/D (from 0 to 4D). The relative peak magnitude of contour interaction for the contrast-modulated C is greater (by ~0.1 logMAR) and more extensive, than for the luminance-modulated C. Dioptric blur up to 2D raises both types of isolated C acuity thresholds similarly, but affects their contour interaction parameters differently. The magnitude of the peak effect is directly related to the unflanked logMAR threshold (or letter size). However with increasing blur, the extent of interaction is maintained for the contrast-modulated C, but reduced significantly for the luminance-modulated C (as for standard luminance letters; Simmers et al, 1999). For these blur levels, contrast-modulated Cs are more subject to contour interaction effects than luminance-modulated Cs. This could be a result of larger integration areas for contrast-modulated stimuli and a differential effect of blur on contrast and luminance modulation sensitivity functions. The Association for Research in Vision and Ophthalmology, Inc. (ARVO) 2010-08-01 Article PeerReviewed application/pdf en http://irep.iium.edu.my/73671/1/Effects%20of%20dioptric%20blur%20on%20foveal%20acuity%20and%20contour%20interaction%20for%20noisy%20Cs%20_%20JOV%20_%20ARVO%20Journals.pdf Waugh, Sarah and Monika, Formankiewicz and Ahmad, Norsham and Hairol, Izzuddin (2010) Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs. Journal of Vision, 10 (7). p. 1330. ISSN 1534-7362 https://jov.arvojournals.org/ 10.1167/10.7.1330
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Waugh, Sarah
Monika, Formankiewicz
Ahmad, Norsham
Hairol, Izzuddin
Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs
description Contour interaction for visual acuity has been found to dissipate with imposed dioptric blur of +1.50D using standard luminance letters and bars (Simmers et al, 1999). It is unclear how dioptric blur affects visual acuity or contour interaction for letters imbedded in noise. We examined the effects of dioptric blur on luminance-modulated and contrast-modulated noise Cs with and without surrounding contours. Stimuli were constructed from random dot dynamic noise, added or multiplied to a square-wave profile. We measured foveal acuity for a square-shaped C with and without four flanking bars separated by 0 to 2 letter widths under different levels of dioptric blur (0-2D with flanks; 0-4D without). Acuity was measured using a method of constant stimuli and 4AFC paradigm for approximately equally visible luminance-modulated and contrast-modulated noisy Cs. Acuity thresholds for isolated contrast-modulated Cs are about 0.3 logMAR higher than for luminance-modulated Cs at all blur levels. The effect of increasing blur on acuity is ~0.3 logMAR/D (from 0 to 4D). The relative peak magnitude of contour interaction for the contrast-modulated C is greater (by ~0.1 logMAR) and more extensive, than for the luminance-modulated C. Dioptric blur up to 2D raises both types of isolated C acuity thresholds similarly, but affects their contour interaction parameters differently. The magnitude of the peak effect is directly related to the unflanked logMAR threshold (or letter size). However with increasing blur, the extent of interaction is maintained for the contrast-modulated C, but reduced significantly for the luminance-modulated C (as for standard luminance letters; Simmers et al, 1999). For these blur levels, contrast-modulated Cs are more subject to contour interaction effects than luminance-modulated Cs. This could be a result of larger integration areas for contrast-modulated stimuli and a differential effect of blur on contrast and luminance modulation sensitivity functions.
format Article
author Waugh, Sarah
Monika, Formankiewicz
Ahmad, Norsham
Hairol, Izzuddin
author_facet Waugh, Sarah
Monika, Formankiewicz
Ahmad, Norsham
Hairol, Izzuddin
author_sort Waugh, Sarah
title Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs
title_short Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs
title_full Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs
title_fullStr Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs
title_full_unstemmed Effects of dioptric blur on foveal acuity and contour interaction for noisy Cs
title_sort effects of dioptric blur on foveal acuity and contour interaction for noisy cs
publisher The Association for Research in Vision and Ophthalmology, Inc. (ARVO)
publishDate 2010
url http://irep.iium.edu.my/73671/1/Effects%20of%20dioptric%20blur%20on%20foveal%20acuity%20and%20contour%20interaction%20for%20noisy%20Cs%20_%20JOV%20_%20ARVO%20Journals.pdf
http://irep.iium.edu.my/73671/
https://jov.arvojournals.org/
_version_ 1643620357433720832