Factors influencing functional outcome of philos plate fixation for proximal humerus fractures

INTRODUCTION: Displaced and unstable proximal humerus fractures are difficult to treat and they have high morbidity especially in elderly. The main goal is to achieve painless shoulder with full recovery in terms of range of movements of the shoulder joint [1]. It is a common occurrence, which acc...

Full description

Saved in:
Bibliographic Details
Main Authors: abdul wahid, Hazwan, Siron @ Baharom, Khairul Nizam, Abdullah, Ahmad Zakiran
Format: Article
Language:English
Published: Malaysian Orthopaedic Association (MOA) 2017
Subjects:
Online Access:http://irep.iium.edu.my/70146/7/FT-01-Hazwan-Ab-Wahid.pdf
http://irep.iium.edu.my/70146/
http://www.morthoj.org/supplements/moa/FT-01-Hazwan-Ab-Wahid.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.70146
record_format dspace
spelling my.iium.irep.701462019-02-14T03:29:36Z http://irep.iium.edu.my/70146/ Factors influencing functional outcome of philos plate fixation for proximal humerus fractures abdul wahid, Hazwan Siron @ Baharom, Khairul Nizam Abdullah, Ahmad Zakiran RD701 Orthopedics INTRODUCTION: Displaced and unstable proximal humerus fractures are difficult to treat and they have high morbidity especially in elderly. The main goal is to achieve painless shoulder with full recovery in terms of range of movements of the shoulder joint [1]. It is a common occurrence, which accounts for 4 to 5% of all fractures incidence [2]. Impingement syndrome is one of the commonest postoperative complication is thought to be due to improper positioning of the plate [3]. This study aim is to appreciate the functional outcomes of Philos plate fixation for proximal humerus fractures and to establish association with high plate positioning with impingement syndrome of the shoulder after Philos plate fixation for proximal humerus fractures METHODS: This is a retrospective study, reviewing 26 patients who had proximal humeral fractures and underwent open reduction and Philos plate fixation between December 2010 and January 2015 in Hospital Tengku Ampuan Afzan, Kuantan, Pahang. Preoperative X-rays or CT scans were inspected, follow-up visits and Xray images were obtained at every follow up consultation to evaluate the plate position and bone union. A distance of 18 mm or less between the upper edge of the plate and the tuberosity was classified as a high plate position. Assessments of impingement syndrome and other complications were done and also functional outcome measured with Constant shoulder scoring system during final follow-up [4]. RESULTS: From 26 patients, 19 were male and 7 were female, mean age was 51.96 (21-78 years old), majority were Malays. All cases achieved union. None of the cases developed complication like malunion, infection, AVN, and loosening of implant while 2 cases complicated with shoulder impingement post operatively. DISCUSSIONS: Among all the factors, age more than 60 years, and high plate position found to be a significant factor in the outcome of the surgery. Neer 3 parts fractures have higher mean of Constant score compare to Neer 4 parts fractures. We also observed that high plate position is significantly associated with impingement syndrome postoperatively with a p value of 0.007. CONCLUSION: This study showed that age, fracture type and plate position were key factors affecting shoulder function after philos locking plate fixation surgery. We recommend that plate should be position at most 19mm from the greater tubercle to prevent impingement syndrome postoperatively and for better functional outcome. Malaysian Orthopaedic Association (MOA) 2017-07-01 Article PeerReviewed application/pdf en http://irep.iium.edu.my/70146/7/FT-01-Hazwan-Ab-Wahid.pdf abdul wahid, Hazwan and Siron @ Baharom, Khairul Nizam and Abdullah, Ahmad Zakiran (2017) Factors influencing functional outcome of philos plate fixation for proximal humerus fractures. Malaysian Orthopaedic Journal, 11 (Supplementary A). FT01-FT01. ISSN 1985-2533 http://www.morthoj.org/supplements/moa/FT-01-Hazwan-Ab-Wahid.pdf
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic RD701 Orthopedics
spellingShingle RD701 Orthopedics
abdul wahid, Hazwan
Siron @ Baharom, Khairul Nizam
Abdullah, Ahmad Zakiran
Factors influencing functional outcome of philos plate fixation for proximal humerus fractures
description INTRODUCTION: Displaced and unstable proximal humerus fractures are difficult to treat and they have high morbidity especially in elderly. The main goal is to achieve painless shoulder with full recovery in terms of range of movements of the shoulder joint [1]. It is a common occurrence, which accounts for 4 to 5% of all fractures incidence [2]. Impingement syndrome is one of the commonest postoperative complication is thought to be due to improper positioning of the plate [3]. This study aim is to appreciate the functional outcomes of Philos plate fixation for proximal humerus fractures and to establish association with high plate positioning with impingement syndrome of the shoulder after Philos plate fixation for proximal humerus fractures METHODS: This is a retrospective study, reviewing 26 patients who had proximal humeral fractures and underwent open reduction and Philos plate fixation between December 2010 and January 2015 in Hospital Tengku Ampuan Afzan, Kuantan, Pahang. Preoperative X-rays or CT scans were inspected, follow-up visits and Xray images were obtained at every follow up consultation to evaluate the plate position and bone union. A distance of 18 mm or less between the upper edge of the plate and the tuberosity was classified as a high plate position. Assessments of impingement syndrome and other complications were done and also functional outcome measured with Constant shoulder scoring system during final follow-up [4]. RESULTS: From 26 patients, 19 were male and 7 were female, mean age was 51.96 (21-78 years old), majority were Malays. All cases achieved union. None of the cases developed complication like malunion, infection, AVN, and loosening of implant while 2 cases complicated with shoulder impingement post operatively. DISCUSSIONS: Among all the factors, age more than 60 years, and high plate position found to be a significant factor in the outcome of the surgery. Neer 3 parts fractures have higher mean of Constant score compare to Neer 4 parts fractures. We also observed that high plate position is significantly associated with impingement syndrome postoperatively with a p value of 0.007. CONCLUSION: This study showed that age, fracture type and plate position were key factors affecting shoulder function after philos locking plate fixation surgery. We recommend that plate should be position at most 19mm from the greater tubercle to prevent impingement syndrome postoperatively and for better functional outcome.
format Article
author abdul wahid, Hazwan
Siron @ Baharom, Khairul Nizam
Abdullah, Ahmad Zakiran
author_facet abdul wahid, Hazwan
Siron @ Baharom, Khairul Nizam
Abdullah, Ahmad Zakiran
author_sort abdul wahid, Hazwan
title Factors influencing functional outcome of philos plate fixation for proximal humerus fractures
title_short Factors influencing functional outcome of philos plate fixation for proximal humerus fractures
title_full Factors influencing functional outcome of philos plate fixation for proximal humerus fractures
title_fullStr Factors influencing functional outcome of philos plate fixation for proximal humerus fractures
title_full_unstemmed Factors influencing functional outcome of philos plate fixation for proximal humerus fractures
title_sort factors influencing functional outcome of philos plate fixation for proximal humerus fractures
publisher Malaysian Orthopaedic Association (MOA)
publishDate 2017
url http://irep.iium.edu.my/70146/7/FT-01-Hazwan-Ab-Wahid.pdf
http://irep.iium.edu.my/70146/
http://www.morthoj.org/supplements/moa/FT-01-Hazwan-Ab-Wahid.pdf
_version_ 1643619167945883648
score 13.211869