Synchronisation of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems
Nowadays, smart grid system is widely used for energy supply system because it is simple, available, less costly, highly efficient and environmentally friendly. Conventionally, inverter techniques are utilized to convert input DC into output AC with the same frequency and phase. These techniques int...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
UPM Press, Universiti Putra Malaysia
2017
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/59679/1/59679_Synchronization%20of%20output%20voltage%20waveforms.pdf http://irep.iium.edu.my/59679/ http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Jul.%202017/15%20JST(S)-0342-2017-5thProof.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.iium.irep.59679 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.596792018-04-13T03:03:43Z http://irep.iium.edu.my/59679/ Synchronisation of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems Rahman, Tawfikur Ibrahimy, Muhammad Ibn Motakabber, S. M. A. Azam, S. M. Kayser T Technology (General) TK452 Electric apparatus and materials. Electric circuits. Electric networks Nowadays, smart grid system is widely used for energy supply system because it is simple, available, less costly, highly efficient and environmentally friendly. Conventionally, inverter techniques are utilized to convert input DC into output AC with the same frequency and phase. These techniques introduce some problems with higher harmonic distortion, phase synchronization, lower quality of waveform and long distance. A three phase synchronous inverters (PSI) have been applied to zero crossing with pulse width modulation (PWM) controller, LCL filter, three phase RLC load, three phase Star-Delta transformer, 5km feeder with 2 MW load. Zero crossing with pulse generator is used to generate the pulse signal for synchronization between inverter and grid system. However, LCL filters have been employed to reduce the system noise. The proposed technique has been used for a balanced three phase load (10 kVAR ) and an input DC voltage of ± 250V. In order to increase the inverter output voltage and current with the fundamental frequency (50Hz) a three phase transformer (100kVA/260V/25kV) has been considered. The system results in conversion efficiency at 97.96% and phase synchronous error for each phase as 4.5 degrees. UPM Press, Universiti Putra Malaysia 2017-07 Article REM application/pdf en http://irep.iium.edu.my/59679/1/59679_Synchronization%20of%20output%20voltage%20waveforms.pdf Rahman, Tawfikur and Ibrahimy, Muhammad Ibn and Motakabber, S. M. A. and Azam, S. M. Kayser (2017) Synchronisation of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems. Pertanika Journal of Science & Technology (JST), 25 (Special issue). pp. 145-156. ISSN 0128-7680 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Jul.%202017/15%20JST(S)-0342-2017-5thProof.pdf |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
T Technology (General) TK452 Electric apparatus and materials. Electric circuits. Electric networks |
spellingShingle |
T Technology (General) TK452 Electric apparatus and materials. Electric circuits. Electric networks Rahman, Tawfikur Ibrahimy, Muhammad Ibn Motakabber, S. M. A. Azam, S. M. Kayser Synchronisation of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems |
description |
Nowadays, smart grid system is widely used for energy supply system because it is simple, available, less costly, highly efficient and environmentally friendly. Conventionally, inverter techniques are utilized to convert input DC into output AC with the same frequency and phase. These techniques introduce some problems with higher harmonic distortion, phase synchronization, lower quality of waveform and long distance. A three phase synchronous inverters (PSI) have been applied to zero crossing with pulse width modulation (PWM) controller, LCL filter, three phase RLC load, three phase Star-Delta transformer, 5km feeder with 2 MW load. Zero crossing with pulse generator is used to generate the pulse signal for synchronization between inverter and grid system. However, LCL filters have been employed to reduce the system noise. The proposed technique has been used for a balanced three phase load (10 kVAR ) and an input DC voltage of ± 250V. In order to increase the inverter output voltage and current with the fundamental frequency (50Hz) a three phase transformer (100kVA/260V/25kV) has been considered. The system results in conversion efficiency at 97.96% and phase synchronous error for each phase as 4.5 degrees. |
format |
Article |
author |
Rahman, Tawfikur Ibrahimy, Muhammad Ibn Motakabber, S. M. A. Azam, S. M. Kayser |
author_facet |
Rahman, Tawfikur Ibrahimy, Muhammad Ibn Motakabber, S. M. A. Azam, S. M. Kayser |
author_sort |
Rahman, Tawfikur |
title |
Synchronisation of output voltage waveforms in phase
synchronous inverter with LCL filter for smart grid systems |
title_short |
Synchronisation of output voltage waveforms in phase
synchronous inverter with LCL filter for smart grid systems |
title_full |
Synchronisation of output voltage waveforms in phase
synchronous inverter with LCL filter for smart grid systems |
title_fullStr |
Synchronisation of output voltage waveforms in phase
synchronous inverter with LCL filter for smart grid systems |
title_full_unstemmed |
Synchronisation of output voltage waveforms in phase
synchronous inverter with LCL filter for smart grid systems |
title_sort |
synchronisation of output voltage waveforms in phase
synchronous inverter with lcl filter for smart grid systems |
publisher |
UPM Press, Universiti Putra Malaysia |
publishDate |
2017 |
url |
http://irep.iium.edu.my/59679/1/59679_Synchronization%20of%20output%20voltage%20waveforms.pdf http://irep.iium.edu.my/59679/ http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Jul.%202017/15%20JST(S)-0342-2017-5thProof.pdf |
_version_ |
1643615637196505088 |
score |
13.209306 |