Optimum initial masking level for Plateau seeking method
The purpose of this study is to establish the optimum initial masking level that can be used in “Plateau Method” of masking. The Minimum Effective Masking Level (MEML) of 30 normal hearing ears was determined at octave frequencies from 250Hz to 4000Hz. Mean MEML for the octave frequencies ranged fro...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2010
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/49079/1/Optimum_initial_masking_level_for_plateu_seeking_method.pdf http://irep.iium.edu.my/49079/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.iium.irep.49079 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.490792022-04-20T01:12:24Z http://irep.iium.edu.my/49079/ Optimum initial masking level for Plateau seeking method Rahmat, Sarah Jamaluddin, Saiful Adli Q Science (General) The purpose of this study is to establish the optimum initial masking level that can be used in “Plateau Method” of masking. The Minimum Effective Masking Level (MEML) of 30 normal hearing ears was determined at octave frequencies from 250Hz to 4000Hz. Mean MEML for the octave frequencies ranged from -1.8 to 0.7 dB SL. There were significant differences of MEML between 250 Hz and 2 KHz, and 250 Hz and 4 KHz (P <0.05) with higher MEML recorded at higher frequencies as compared to 250Hz. MANOVA revealed no significant difference of MEML between male and female across frequencies (P<0.05). Pearson correlation revealed a strong positive significant linear relationship between pure tone level and masker level for all frequencies (P<0.05; 0.95<r<1.0) which suggests that the narrowband noise used effectively masked the pure tone signals. The highest recorded MEML was 5 dB SL at all octave frequencies. Taking a conservative approach, this value was used in the calculation of optimum initial masking level in addition to 5 dB to ensure significant threshold shift. It is recommended that 10 dB SL of initial masking level is applied in audiology clinics in Malaysia as it is adequate to effectively mask the pure tone thresholds. 2010 Conference or Workshop Item NonPeerReviewed application/pdf en http://irep.iium.edu.my/49079/1/Optimum_initial_masking_level_for_plateu_seeking_method.pdf Rahmat, Sarah and Jamaluddin, Saiful Adli (2010) Optimum initial masking level for Plateau seeking method. In: Asia Pacific Conference of Speech, Language and Hearing Sciences 2010, 3rd- 4th May 2010, Kuala Lumpur. (Unpublished) |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
Q Science (General) |
spellingShingle |
Q Science (General) Rahmat, Sarah Jamaluddin, Saiful Adli Optimum initial masking level for Plateau seeking method |
description |
The purpose of this study is to establish the optimum initial masking level that can be used in “Plateau Method” of masking. The Minimum Effective Masking Level (MEML) of 30 normal hearing ears was determined at octave frequencies from 250Hz to 4000Hz. Mean MEML for the octave frequencies ranged from -1.8 to 0.7 dB SL. There were significant differences of MEML between 250 Hz and 2 KHz, and 250 Hz and 4 KHz (P <0.05) with higher MEML recorded at higher frequencies as compared to 250Hz. MANOVA revealed no significant difference of MEML between male and female across frequencies (P<0.05). Pearson correlation revealed a strong positive significant linear relationship between pure tone level and masker level for all frequencies (P<0.05; 0.95<r<1.0) which suggests that the narrowband noise used effectively masked the pure tone signals. The highest recorded MEML was 5 dB SL at all octave frequencies. Taking a conservative approach, this value was used in the calculation of optimum initial masking level in addition to 5 dB to ensure significant threshold shift. It is recommended that 10 dB SL of initial masking level is applied in audiology clinics in Malaysia as it is adequate to effectively mask the pure tone thresholds. |
format |
Conference or Workshop Item |
author |
Rahmat, Sarah Jamaluddin, Saiful Adli |
author_facet |
Rahmat, Sarah Jamaluddin, Saiful Adli |
author_sort |
Rahmat, Sarah |
title |
Optimum initial masking level for Plateau seeking method |
title_short |
Optimum initial masking level for Plateau seeking method |
title_full |
Optimum initial masking level for Plateau seeking method |
title_fullStr |
Optimum initial masking level for Plateau seeking method |
title_full_unstemmed |
Optimum initial masking level for Plateau seeking method |
title_sort |
optimum initial masking level for plateau seeking method |
publishDate |
2010 |
url |
http://irep.iium.edu.my/49079/1/Optimum_initial_masking_level_for_plateu_seeking_method.pdf http://irep.iium.edu.my/49079/ |
_version_ |
1731225353391702016 |
score |
13.214268 |