Tumor volume determination technique using pixel filling and discrete integral function

The subject of tumor has generated lots of interest from the medical point of view and recently from engineering/research perspective owing to advancement in medical equipment and increased computerization in many areas including medical field. This paper discusses a post segmentation tumor volume...

Full description

Saved in:
Bibliographic Details
Main Authors: Aboaba, Abdulfattah A., Hameed, Shihab Ahmed, Khalifa, Othman Omran, Hassan Abdalla Hashim, Aisha, Harun @ Haron, Rahmat, Mohd Zain, Norzaini Rose
Format: Article
Language:English
Published: Engineering and Technology Publishing 2015
Subjects:
Online Access:http://irep.iium.edu.my/45768/1/Tumor_Volume_23-H2001-prof_shihab_2015.pdf
http://irep.iium.edu.my/45768/
http://www.ijpmbs.com/index.php?m=content&c=index&a=show&catid=132&id=169
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.45768
record_format dspace
spelling my.iium.irep.457682020-10-27T00:47:37Z http://irep.iium.edu.my/45768/ Tumor volume determination technique using pixel filling and discrete integral function Aboaba, Abdulfattah A. Hameed, Shihab Ahmed Khalifa, Othman Omran Hassan Abdalla Hashim, Aisha Harun @ Haron, Rahmat Mohd Zain, Norzaini Rose RD Surgery TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices The subject of tumor has generated lots of interest from the medical point of view and recently from engineering/research perspective owing to advancement in medical equipment and increased computerization in many areas including medical field. This paper discusses a post segmentation tumor volume determination technique that employs mainly pixel filling, and the application of discrete integral function to determine tumor volume. The prior steps taken involve finding pixel area resolution, image field of view (FOV), then FFT-Based interpolation to achieve smaller decimation of tumor area, and finally the use of discrete integral function (DIF) to accurately determine tumor volume. The result of the work will enhance the field of oncology in general, and image guided surgery (IGS) in particular. Engineering and Technology Publishing 2015-07 Article PeerReviewed application/pdf en http://irep.iium.edu.my/45768/1/Tumor_Volume_23-H2001-prof_shihab_2015.pdf Aboaba, Abdulfattah A. and Hameed, Shihab Ahmed and Khalifa, Othman Omran and Hassan Abdalla Hashim, Aisha and Harun @ Haron, Rahmat and Mohd Zain, Norzaini Rose (2015) Tumor volume determination technique using pixel filling and discrete integral function. International Journal of Pharma Medicine and Biological Sciences, 4 (3). pp. 188-191. ISSN 2278-5221 http://www.ijpmbs.com/index.php?m=content&c=index&a=show&catid=132&id=169
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic RD Surgery
TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices
spellingShingle RD Surgery
TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices
Aboaba, Abdulfattah A.
Hameed, Shihab Ahmed
Khalifa, Othman Omran
Hassan Abdalla Hashim, Aisha
Harun @ Haron, Rahmat
Mohd Zain, Norzaini Rose
Tumor volume determination technique using pixel filling and discrete integral function
description The subject of tumor has generated lots of interest from the medical point of view and recently from engineering/research perspective owing to advancement in medical equipment and increased computerization in many areas including medical field. This paper discusses a post segmentation tumor volume determination technique that employs mainly pixel filling, and the application of discrete integral function to determine tumor volume. The prior steps taken involve finding pixel area resolution, image field of view (FOV), then FFT-Based interpolation to achieve smaller decimation of tumor area, and finally the use of discrete integral function (DIF) to accurately determine tumor volume. The result of the work will enhance the field of oncology in general, and image guided surgery (IGS) in particular.
format Article
author Aboaba, Abdulfattah A.
Hameed, Shihab Ahmed
Khalifa, Othman Omran
Hassan Abdalla Hashim, Aisha
Harun @ Haron, Rahmat
Mohd Zain, Norzaini Rose
author_facet Aboaba, Abdulfattah A.
Hameed, Shihab Ahmed
Khalifa, Othman Omran
Hassan Abdalla Hashim, Aisha
Harun @ Haron, Rahmat
Mohd Zain, Norzaini Rose
author_sort Aboaba, Abdulfattah A.
title Tumor volume determination technique using pixel filling and discrete integral function
title_short Tumor volume determination technique using pixel filling and discrete integral function
title_full Tumor volume determination technique using pixel filling and discrete integral function
title_fullStr Tumor volume determination technique using pixel filling and discrete integral function
title_full_unstemmed Tumor volume determination technique using pixel filling and discrete integral function
title_sort tumor volume determination technique using pixel filling and discrete integral function
publisher Engineering and Technology Publishing
publishDate 2015
url http://irep.iium.edu.my/45768/1/Tumor_Volume_23-H2001-prof_shihab_2015.pdf
http://irep.iium.edu.my/45768/
http://www.ijpmbs.com/index.php?m=content&c=index&a=show&catid=132&id=169
_version_ 1683230283005952000
score 13.18916