Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement

We have developed a new ultrasound Doppler blood flow velocimeter which had a B-mode image system. A measurement of blood flow velocity was difficult under the movement, because a blood vessel was moved with muscle movement. But, this equipment is able to trace vessel position by using B-mode image....

Full description

Saved in:
Bibliographic Details
Main Authors: Yuji , HIRAO, Noor Azmi, Azran Azhim, Yohsuke , KINOUCHI
Format: Article
Language:English
Published: 2009
Subjects:
Online Access:http://irep.iium.edu.my/44092/1/44092_-_Development_of_Blood_Flow_Velocimeter_of_Vessel_Position_Trace_Type_and_Measurement_of_Its_Velocity_in_the_Elbow_Flexor_and_Extensor_Movement.pdf
http://irep.iium.edu.my/44092/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.44092
record_format dspace
spelling my.iium.irep.440922016-04-06T02:41:14Z http://irep.iium.edu.my/44092/ Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement Yuji , HIRAO Noor Azmi, Azran Azhim Yohsuke , KINOUCHI TP248.13 Biotechnology We have developed a new ultrasound Doppler blood flow velocimeter which had a B-mode image system. A measurement of blood flow velocity was difficult under the movement, because a blood vessel was moved with muscle movement. But, this equipment is able to trace vessel position by using B-mode image. In this paper, attribute and schema of this equipment are explained. As an incidence angle of ultrasound beam changed under the movement, its correction was suggested. The result of application experiment, this equipment was useful for the measurement under the movement. 2009 Article REM application/pdf en http://irep.iium.edu.my/44092/1/44092_-_Development_of_Blood_Flow_Velocimeter_of_Vessel_Position_Trace_Type_and_Measurement_of_Its_Velocity_in_the_Elbow_Flexor_and_Extensor_Movement.pdf Yuji , HIRAO and Noor Azmi, Azran Azhim and Yohsuke , KINOUCHI (2009) Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement. IEICE TRANSACTIONS on Information and Systems , J92-D (1). pp. 162-175. ISSN 1745-1361
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic TP248.13 Biotechnology
spellingShingle TP248.13 Biotechnology
Yuji , HIRAO
Noor Azmi, Azran Azhim
Yohsuke , KINOUCHI
Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
description We have developed a new ultrasound Doppler blood flow velocimeter which had a B-mode image system. A measurement of blood flow velocity was difficult under the movement, because a blood vessel was moved with muscle movement. But, this equipment is able to trace vessel position by using B-mode image. In this paper, attribute and schema of this equipment are explained. As an incidence angle of ultrasound beam changed under the movement, its correction was suggested. The result of application experiment, this equipment was useful for the measurement under the movement.
format Article
author Yuji , HIRAO
Noor Azmi, Azran Azhim
Yohsuke , KINOUCHI
author_facet Yuji , HIRAO
Noor Azmi, Azran Azhim
Yohsuke , KINOUCHI
author_sort Yuji , HIRAO
title Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_short Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_full Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_fullStr Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_full_unstemmed Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_sort development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
publishDate 2009
url http://irep.iium.edu.my/44092/1/44092_-_Development_of_Blood_Flow_Velocimeter_of_Vessel_Position_Trace_Type_and_Measurement_of_Its_Velocity_in_the_Elbow_Flexor_and_Extensor_Movement.pdf
http://irep.iium.edu.my/44092/
_version_ 1643612509410689024
score 13.160551