Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection.

A simple, rapid and sensitive method termed as dispersive liquid–liquid microextraction (DLLME) combined with gas chromatography-electron capture detector (GC-ECD) was developed for the determination of selected organophosphorus pesticides (OPPs) namely chlorpyrifos, dimethoate and diazinon in wat...

Full description

Saved in:
Bibliographic Details
Main Authors: Sanagi, Mohd Marsin, Mokhtar, Siti Umairah, Wan Ibrahim, Wan Aini, Miskam, Mazidatulakmam
Format: Article
Language:English
Published: Malaysian Society of Analytical Sciences (ANALIS), UKM 2011
Subjects:
Online Access:http://irep.iium.edu.my/43220/1/marsin-2.pdf
http://irep.iium.edu.my/43220/
http://www.ukm.my/mjas/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.43220
record_format dspace
spelling my.iium.irep.432202015-06-09T06:40:00Z http://irep.iium.edu.my/43220/ Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection. Sanagi, Mohd Marsin Mokhtar, Siti Umairah Wan Ibrahim, Wan Aini Miskam, Mazidatulakmam QD Chemistry A simple, rapid and sensitive method termed as dispersive liquid–liquid microextraction (DLLME) combined with gas chromatography-electron capture detector (GC-ECD) was developed for the determination of selected organophosphorus pesticides (OPPs) namely chlorpyrifos, dimethoate and diazinon in water sample. In this method, a mixture of carbon disulfide, CS2 (extraction solvent) and methanol (disperser solvent) was rapidly injected using syringe into the 5.00 mL water sample to form a cloudy solution where the OPPs were extracted into the fine droplets of extraction solvent. Upon centrifugation for 3 min at 3500 rpm, the fine droplets were sedimented at the bottom of the centrifuge tube. Sedimented phase (1μL) was injected into the GC-ECD for separation and determination of OPPs. Important extraction parameters, such as type of disperser solvent, volume of extraction solvent and volume of disperser solvent were investigated. The optimized conditions for DLLME of the selected OPPs were methanol as disperser solvent, 30 μL of extraction solvent (CS2 ) and 1.0 mL of disperser solvent (methanol). Under the optimum extraction conditions, the method showed good linearity in the range of 0.1 to 1.0 μg/mL with correlation coefficient (r 2 ), in the range of 0.9976 to 0.9994 and low limits of detection (LOD) between 0.047 and 0.201 μg/mL. The proposed method provided acceptable recoveries (72.67- 144%) with good RSDs ranging from 2.74% to 7.48%. This method was successfully applied to the determination of OPPs in water samples obtained from a golf course and chlorpyrifos and diazinon were detected at concentration 0.18 μg/mL and 0.07 μg/mL, respectively. Malaysian Society of Analytical Sciences (ANALIS), UKM 2011 Article REM application/pdf en http://irep.iium.edu.my/43220/1/marsin-2.pdf Sanagi, Mohd Marsin and Mokhtar, Siti Umairah and Wan Ibrahim, Wan Aini and Miskam, Mazidatulakmam (2011) Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection. The Malaysian Journal of Analytical Sciences, 15 (2). pp. 232-239. ISSN 1394-2506 http://www.ukm.my/mjas/
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic QD Chemistry
spellingShingle QD Chemistry
Sanagi, Mohd Marsin
Mokhtar, Siti Umairah
Wan Ibrahim, Wan Aini
Miskam, Mazidatulakmam
Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection.
description A simple, rapid and sensitive method termed as dispersive liquid–liquid microextraction (DLLME) combined with gas chromatography-electron capture detector (GC-ECD) was developed for the determination of selected organophosphorus pesticides (OPPs) namely chlorpyrifos, dimethoate and diazinon in water sample. In this method, a mixture of carbon disulfide, CS2 (extraction solvent) and methanol (disperser solvent) was rapidly injected using syringe into the 5.00 mL water sample to form a cloudy solution where the OPPs were extracted into the fine droplets of extraction solvent. Upon centrifugation for 3 min at 3500 rpm, the fine droplets were sedimented at the bottom of the centrifuge tube. Sedimented phase (1μL) was injected into the GC-ECD for separation and determination of OPPs. Important extraction parameters, such as type of disperser solvent, volume of extraction solvent and volume of disperser solvent were investigated. The optimized conditions for DLLME of the selected OPPs were methanol as disperser solvent, 30 μL of extraction solvent (CS2 ) and 1.0 mL of disperser solvent (methanol). Under the optimum extraction conditions, the method showed good linearity in the range of 0.1 to 1.0 μg/mL with correlation coefficient (r 2 ), in the range of 0.9976 to 0.9994 and low limits of detection (LOD) between 0.047 and 0.201 μg/mL. The proposed method provided acceptable recoveries (72.67- 144%) with good RSDs ranging from 2.74% to 7.48%. This method was successfully applied to the determination of OPPs in water samples obtained from a golf course and chlorpyrifos and diazinon were detected at concentration 0.18 μg/mL and 0.07 μg/mL, respectively.
format Article
author Sanagi, Mohd Marsin
Mokhtar, Siti Umairah
Wan Ibrahim, Wan Aini
Miskam, Mazidatulakmam
author_facet Sanagi, Mohd Marsin
Mokhtar, Siti Umairah
Wan Ibrahim, Wan Aini
Miskam, Mazidatulakmam
author_sort Sanagi, Mohd Marsin
title Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection.
title_short Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection.
title_full Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection.
title_fullStr Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection.
title_full_unstemmed Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection.
title_sort determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection.
publisher Malaysian Society of Analytical Sciences (ANALIS), UKM
publishDate 2011
url http://irep.iium.edu.my/43220/1/marsin-2.pdf
http://irep.iium.edu.my/43220/
http://www.ukm.my/mjas/
_version_ 1643612346976829440
score 13.209306