An assessment of indoor air quality in two contrasting buildings in London

Background: People spend most of their time indoors in buildings such as schools and offices as well as their homes. Over recent years there has been increased interest in Indoor Air Quality (IAQ) suggesting that the contribution of outdoor pollutant penetration and indoor airborne particulate and g...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Aris, Mohd Shukri, Barratt, Benjamin, Kelly, Frank
Format: Conference or Workshop Item
Language:English
Published: 2011
Subjects:
Online Access:http://irep.iium.edu.my/40840/5/40840-new.pdf
http://irep.iium.edu.my/40840/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.40840
record_format dspace
spelling my.iium.irep.408402016-04-28T06:45:11Z http://irep.iium.edu.my/40840/ An assessment of indoor air quality in two contrasting buildings in London Mohd Aris, Mohd Shukri Barratt, Benjamin Kelly, Frank QH301 Biology RA1190 Toxicology Background: People spend most of their time indoors in buildings such as schools and offices as well as their homes. Over recent years there has been increased interest in Indoor Air Quality (IAQ) suggesting that the contribution of outdoor pollutant penetration and indoor airborne particulate and gaseous pollutants may be responsible for the aggregation of a number of respiratory illnesses. Because of these possible health implications it is important to understand the characteristics of each air pollutant inside/outside (I/O) the building and the variables affecting the degree of exposure. The findings from this study will be used to establish a London Indoor Air Quality Network to compliment the existing outdoor network. Objectives: Long term monitoring of particulate matter (PM) and gaseous pollutant (NOx & O3) inside and outside two different buildings was undertaken. The sites represent two extreme building conditions – one which is a mechanically ventilated office building adjacent to a busy road and the second, a naturally ventilated school building located in a London suburb. Building occupancy, ventilation details and indoor activity diaries were recorded to help interpret gaseous and particulate pollutant characteristics and sources. Methodology: Indoor and outdoor gaseous pollutants were monitored by continuous Oxides of Nitrogen (NOx)and Ozone (O3) analysers; Particle mass concentration was simultaneously monitored using Dust OSIRIS Instruments. These data were remotely accessed via in-house database software. Exposed microfibre glass filters were collected routinely for further particulate oxidative potential analysis. Results: At the mechanically ventilated office building (roadside), diurnal variation of indoor NOx (180 μg m-3) was found to be influenced by outdoor NOx (mean concentration 220 μg m-3). High I/O NO2 (ratio, R > 0.74) concentration were observed during week days and at the weekend. Mean concentrations I/O were highly correlated throughout the day and night (p < 0.01) and it is estimated that about 84% (day) and 95% (night) outdoor NOx transgressed indoors. In contrast, a different pattern of diurnal variation profiles were observed in the naturally ventilated school building (suburban). Indoor NOx concentration was dominated by an indoor NO source. Particulate concentration of indoor PM10 & PM2.5 was observed to be higher than outdoor concentrations, especially during occupied periods. The I/O PM ratios were found to differ significantly (p-value <0.05) between weekdays and weekend for fractionated PM10 & PM2.5. During weekdays only 6.8, 2.3 & 2.8% variation in the indoor concentration of PM10, PM2.5 & PM1 could be attributed to the outdoor concentration respectively. The low values of R2 revealed the independent sources of particulate matter in the indoor environment at the classroom. Conclusion: These monitoring results have revealed a number of important building design and occupancy issues that affect indoor air quality. 2011-05-18 Conference or Workshop Item REM application/pdf en http://irep.iium.edu.my/40840/5/40840-new.pdf Mohd Aris, Mohd Shukri and Barratt, Benjamin and Kelly, Frank (2011) An assessment of indoor air quality in two contrasting buildings in London. In: Analytical & Environmental Sciences Division, Postgraduate Research Symposium, 18th May 2011, London, United Kingdom. (Unpublished)
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic QH301 Biology
RA1190 Toxicology
spellingShingle QH301 Biology
RA1190 Toxicology
Mohd Aris, Mohd Shukri
Barratt, Benjamin
Kelly, Frank
An assessment of indoor air quality in two contrasting buildings in London
description Background: People spend most of their time indoors in buildings such as schools and offices as well as their homes. Over recent years there has been increased interest in Indoor Air Quality (IAQ) suggesting that the contribution of outdoor pollutant penetration and indoor airborne particulate and gaseous pollutants may be responsible for the aggregation of a number of respiratory illnesses. Because of these possible health implications it is important to understand the characteristics of each air pollutant inside/outside (I/O) the building and the variables affecting the degree of exposure. The findings from this study will be used to establish a London Indoor Air Quality Network to compliment the existing outdoor network. Objectives: Long term monitoring of particulate matter (PM) and gaseous pollutant (NOx & O3) inside and outside two different buildings was undertaken. The sites represent two extreme building conditions – one which is a mechanically ventilated office building adjacent to a busy road and the second, a naturally ventilated school building located in a London suburb. Building occupancy, ventilation details and indoor activity diaries were recorded to help interpret gaseous and particulate pollutant characteristics and sources. Methodology: Indoor and outdoor gaseous pollutants were monitored by continuous Oxides of Nitrogen (NOx)and Ozone (O3) analysers; Particle mass concentration was simultaneously monitored using Dust OSIRIS Instruments. These data were remotely accessed via in-house database software. Exposed microfibre glass filters were collected routinely for further particulate oxidative potential analysis. Results: At the mechanically ventilated office building (roadside), diurnal variation of indoor NOx (180 μg m-3) was found to be influenced by outdoor NOx (mean concentration 220 μg m-3). High I/O NO2 (ratio, R > 0.74) concentration were observed during week days and at the weekend. Mean concentrations I/O were highly correlated throughout the day and night (p < 0.01) and it is estimated that about 84% (day) and 95% (night) outdoor NOx transgressed indoors. In contrast, a different pattern of diurnal variation profiles were observed in the naturally ventilated school building (suburban). Indoor NOx concentration was dominated by an indoor NO source. Particulate concentration of indoor PM10 & PM2.5 was observed to be higher than outdoor concentrations, especially during occupied periods. The I/O PM ratios were found to differ significantly (p-value <0.05) between weekdays and weekend for fractionated PM10 & PM2.5. During weekdays only 6.8, 2.3 & 2.8% variation in the indoor concentration of PM10, PM2.5 & PM1 could be attributed to the outdoor concentration respectively. The low values of R2 revealed the independent sources of particulate matter in the indoor environment at the classroom. Conclusion: These monitoring results have revealed a number of important building design and occupancy issues that affect indoor air quality.
format Conference or Workshop Item
author Mohd Aris, Mohd Shukri
Barratt, Benjamin
Kelly, Frank
author_facet Mohd Aris, Mohd Shukri
Barratt, Benjamin
Kelly, Frank
author_sort Mohd Aris, Mohd Shukri
title An assessment of indoor air quality in two contrasting buildings in London
title_short An assessment of indoor air quality in two contrasting buildings in London
title_full An assessment of indoor air quality in two contrasting buildings in London
title_fullStr An assessment of indoor air quality in two contrasting buildings in London
title_full_unstemmed An assessment of indoor air quality in two contrasting buildings in London
title_sort assessment of indoor air quality in two contrasting buildings in london
publishDate 2011
url http://irep.iium.edu.my/40840/5/40840-new.pdf
http://irep.iium.edu.my/40840/
_version_ 1643611900733292544
score 13.211869