Parametric study of earth-to-air heat exchanger in Malaysian climate

The technology, where the ground was used as a heat sink to produce cooler air, has been an area of interest in Malaysia even before National Green Technology Policy was launched in 2009. This simulation study is based on ASHRAE Weather database, local data collected in previous field studies at Uni...

Full description

Saved in:
Bibliographic Details
Main Authors: Ibrahim, Md. Najib, Sanusi, Aliyah Nur Zafirah, Ali, Maisarah, Aziz Ahmed, Soran Hama
Format: Conference or Workshop Item
Language:English
Published: 2013
Subjects:
Online Access:http://irep.iium.edu.my/32504/1/Sanusi_Ibrahim_ACSEE_Offprint_0140.pdf
http://irep.iium.edu.my/32504/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.32504
record_format dspace
spelling my.iium.irep.325042021-06-23T15:29:02Z http://irep.iium.edu.my/32504/ Parametric study of earth-to-air heat exchanger in Malaysian climate Ibrahim, Md. Najib Sanusi, Aliyah Nur Zafirah Ali, Maisarah Aziz Ahmed, Soran Hama TH7005 Heating and ventilation TJ163.26 Energy conservation The technology, where the ground was used as a heat sink to produce cooler air, has been an area of interest in Malaysia even before National Green Technology Policy was launched in 2009. This simulation study is based on ASHRAE Weather database, local data collected in previous field studies at Universiti Teknologi Malaysia Skudai Campus in Johor and International Islamic University Malaysia Gombak Campus in Selangor. This study investigates the parameters influencing the cooling potential of Earth-to-Air Heat Exchanger (EAHE). 2013-06-06 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/32504/1/Sanusi_Ibrahim_ACSEE_Offprint_0140.pdf Ibrahim, Md. Najib and Sanusi, Aliyah Nur Zafirah and Ali, Maisarah and Aziz Ahmed, Soran Hama (2013) Parametric study of earth-to-air heat exchanger in Malaysian climate. In: The Asian Conference on Sustainability, Energy and the Environment 2013, 6-9 June 2013, Osaka, Japan.
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic TH7005 Heating and ventilation
TJ163.26 Energy conservation
spellingShingle TH7005 Heating and ventilation
TJ163.26 Energy conservation
Ibrahim, Md. Najib
Sanusi, Aliyah Nur Zafirah
Ali, Maisarah
Aziz Ahmed, Soran Hama
Parametric study of earth-to-air heat exchanger in Malaysian climate
description The technology, where the ground was used as a heat sink to produce cooler air, has been an area of interest in Malaysia even before National Green Technology Policy was launched in 2009. This simulation study is based on ASHRAE Weather database, local data collected in previous field studies at Universiti Teknologi Malaysia Skudai Campus in Johor and International Islamic University Malaysia Gombak Campus in Selangor. This study investigates the parameters influencing the cooling potential of Earth-to-Air Heat Exchanger (EAHE).
format Conference or Workshop Item
author Ibrahim, Md. Najib
Sanusi, Aliyah Nur Zafirah
Ali, Maisarah
Aziz Ahmed, Soran Hama
author_facet Ibrahim, Md. Najib
Sanusi, Aliyah Nur Zafirah
Ali, Maisarah
Aziz Ahmed, Soran Hama
author_sort Ibrahim, Md. Najib
title Parametric study of earth-to-air heat exchanger in Malaysian climate
title_short Parametric study of earth-to-air heat exchanger in Malaysian climate
title_full Parametric study of earth-to-air heat exchanger in Malaysian climate
title_fullStr Parametric study of earth-to-air heat exchanger in Malaysian climate
title_full_unstemmed Parametric study of earth-to-air heat exchanger in Malaysian climate
title_sort parametric study of earth-to-air heat exchanger in malaysian climate
publishDate 2013
url http://irep.iium.edu.my/32504/1/Sanusi_Ibrahim_ACSEE_Offprint_0140.pdf
http://irep.iium.edu.my/32504/
_version_ 1703960137802186752
score 13.159267