Optimization of a cooling system in data centers

Rapid growth in the information and communication technology has increased the demand for equipment in data centers. However, this is not followed by the expansion of space. The increase in high density data center equipment gives impact to the increase heat dissipation. Cooling system in a data ce...

Full description

Saved in:
Bibliographic Details
Main Authors: Ali, Maisarah, Jusoff, Kamaruzzaman, Romadhan, Rahmat, Abakr, Yousifabdalla
Format: Article
Language:English
Published: Kaerntner Botanikzentrum 2012
Subjects:
Online Access:http://irep.iium.edu.my/28389/1/WulMAISARAHWulfenia_journal.pdf
http://irep.iium.edu.my/28389/
http://www.multidisciplinarywulfenia.org/about/index.html
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.28389
record_format dspace
spelling my.iium.irep.283892013-02-19T05:51:08Z http://irep.iium.edu.my/28389/ Optimization of a cooling system in data centers Ali, Maisarah Jusoff, Kamaruzzaman Romadhan, Rahmat Abakr, Yousifabdalla TJ163.26 Energy conservation Rapid growth in the information and communication technology has increased the demand for equipment in data centers. However, this is not followed by the expansion of space. The increase in high density data center equipment gives impact to the increase heat dissipation. Cooling system in a data center consumes the highest power utilization after the IT equipment. The optimization of performance of the cooling system will give significant benefit for energy efficiency. The objective of the study is to show the importance of numerical simulation in order to find the optimum arrangement of racks in data centers. Optimization could be achieved by the arrangement of racks position and improvement in the cooling system and airflow management. Models and simulation of Computational Fluid Dynamics (CFD) are developed for the room and equipment of data center where theeffect to temperature profiles will be observed. A case study of data center design in Kuala Lumpur with 30 racks of equipment and combination of raised floor cooling and spot cooling was carried out. Results of CFD simulation show the problems arose in data center cooling and improvement was suggested to improve the distribution of cooling and reduction of hot spots. Kaerntner Botanikzentrum 2012-09 Article REM application/pdf en http://irep.iium.edu.my/28389/1/WulMAISARAHWulfenia_journal.pdf Ali, Maisarah and Jusoff, Kamaruzzaman and Romadhan, Rahmat and Abakr, Yousifabdalla (2012) Optimization of a cooling system in data centers. Wulfenia Journal, 19 (9). pp. 196-214. ISSN 1561-882X http://www.multidisciplinarywulfenia.org/about/index.html
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic TJ163.26 Energy conservation
spellingShingle TJ163.26 Energy conservation
Ali, Maisarah
Jusoff, Kamaruzzaman
Romadhan, Rahmat
Abakr, Yousifabdalla
Optimization of a cooling system in data centers
description Rapid growth in the information and communication technology has increased the demand for equipment in data centers. However, this is not followed by the expansion of space. The increase in high density data center equipment gives impact to the increase heat dissipation. Cooling system in a data center consumes the highest power utilization after the IT equipment. The optimization of performance of the cooling system will give significant benefit for energy efficiency. The objective of the study is to show the importance of numerical simulation in order to find the optimum arrangement of racks in data centers. Optimization could be achieved by the arrangement of racks position and improvement in the cooling system and airflow management. Models and simulation of Computational Fluid Dynamics (CFD) are developed for the room and equipment of data center where theeffect to temperature profiles will be observed. A case study of data center design in Kuala Lumpur with 30 racks of equipment and combination of raised floor cooling and spot cooling was carried out. Results of CFD simulation show the problems arose in data center cooling and improvement was suggested to improve the distribution of cooling and reduction of hot spots.
format Article
author Ali, Maisarah
Jusoff, Kamaruzzaman
Romadhan, Rahmat
Abakr, Yousifabdalla
author_facet Ali, Maisarah
Jusoff, Kamaruzzaman
Romadhan, Rahmat
Abakr, Yousifabdalla
author_sort Ali, Maisarah
title Optimization of a cooling system in data centers
title_short Optimization of a cooling system in data centers
title_full Optimization of a cooling system in data centers
title_fullStr Optimization of a cooling system in data centers
title_full_unstemmed Optimization of a cooling system in data centers
title_sort optimization of a cooling system in data centers
publisher Kaerntner Botanikzentrum
publishDate 2012
url http://irep.iium.edu.my/28389/1/WulMAISARAHWulfenia_journal.pdf
http://irep.iium.edu.my/28389/
http://www.multidisciplinarywulfenia.org/about/index.html
_version_ 1643609494434873344
score 13.160551