Parametric system identification of thermoelectric cooler for single photon avalanche diode application

The purpose of this study is to model the thermoelectric coolers (TEC) by means of computational intelligence system identification. Thermoelectric coolers are widely used in cooling, maintaining and stabilizing the temperature of the Single photon avalanche diode (SPAD). SPAD is a temperature sensi...

Full description

Saved in:
Bibliographic Details
Main Authors: Samsuddin, Nurul Izzati, Ahmad, Salmiah, Hasbullah, Nurul Fadzlin, Toha, Siti Fauziah
Format: Article
Language:English
Published: Maxwell Scientific Organization, 2012 2013
Subjects:
Online Access:http://irep.iium.edu.my/27869/4/salmiah_v6-712-719.pdf
http://irep.iium.edu.my/27869/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.27869
record_format dspace
spelling my.iium.irep.278692022-07-14T03:54:43Z http://irep.iium.edu.my/27869/ Parametric system identification of thermoelectric cooler for single photon avalanche diode application Samsuddin, Nurul Izzati Ahmad, Salmiah Hasbullah, Nurul Fadzlin Toha, Siti Fauziah TJ212 Control engineering The purpose of this study is to model the thermoelectric coolers (TEC) by means of computational intelligence system identification. Thermoelectric coolers are widely used in cooling, maintaining and stabilizing the temperature of the Single photon avalanche diode (SPAD). SPAD is a temperature sensitive optoelectronic device, where even a slight variation in temperature can cause unstable performance in quantum efficiency, responsitivity and dark counts. However, it is not a simple task to derive a mathematical model for TEC since it varies with the operating condition. In this paper, particle swarm optimization (PSO) was used in order to identify the mathematical model of the multistage TEC (1639733 from Element 14), which encapsulates dynamics of the SPAD, heatsink and components of the cooling heat exchanger. The model was validated by correlation tests, percentage accuracy and also by comparing its time and frequency responses against that of the TEC. It was found that the obtained model has a good representation of the actual system. Maxwell Scientific Organization, 2012 2013-06-20 Article PeerReviewed application/pdf en http://irep.iium.edu.my/27869/4/salmiah_v6-712-719.pdf Samsuddin, Nurul Izzati and Ahmad, Salmiah and Hasbullah, Nurul Fadzlin and Toha, Siti Fauziah (2013) Parametric system identification of thermoelectric cooler for single photon avalanche diode application. Research Journal of Applied Sciences, Engineering and Technology, 6 (4). pp. 712-719. ISSN 2040-7467 (O); 2040-7459 (P)
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic TJ212 Control engineering
spellingShingle TJ212 Control engineering
Samsuddin, Nurul Izzati
Ahmad, Salmiah
Hasbullah, Nurul Fadzlin
Toha, Siti Fauziah
Parametric system identification of thermoelectric cooler for single photon avalanche diode application
description The purpose of this study is to model the thermoelectric coolers (TEC) by means of computational intelligence system identification. Thermoelectric coolers are widely used in cooling, maintaining and stabilizing the temperature of the Single photon avalanche diode (SPAD). SPAD is a temperature sensitive optoelectronic device, where even a slight variation in temperature can cause unstable performance in quantum efficiency, responsitivity and dark counts. However, it is not a simple task to derive a mathematical model for TEC since it varies with the operating condition. In this paper, particle swarm optimization (PSO) was used in order to identify the mathematical model of the multistage TEC (1639733 from Element 14), which encapsulates dynamics of the SPAD, heatsink and components of the cooling heat exchanger. The model was validated by correlation tests, percentage accuracy and also by comparing its time and frequency responses against that of the TEC. It was found that the obtained model has a good representation of the actual system.
format Article
author Samsuddin, Nurul Izzati
Ahmad, Salmiah
Hasbullah, Nurul Fadzlin
Toha, Siti Fauziah
author_facet Samsuddin, Nurul Izzati
Ahmad, Salmiah
Hasbullah, Nurul Fadzlin
Toha, Siti Fauziah
author_sort Samsuddin, Nurul Izzati
title Parametric system identification of thermoelectric cooler for single photon avalanche diode application
title_short Parametric system identification of thermoelectric cooler for single photon avalanche diode application
title_full Parametric system identification of thermoelectric cooler for single photon avalanche diode application
title_fullStr Parametric system identification of thermoelectric cooler for single photon avalanche diode application
title_full_unstemmed Parametric system identification of thermoelectric cooler for single photon avalanche diode application
title_sort parametric system identification of thermoelectric cooler for single photon avalanche diode application
publisher Maxwell Scientific Organization, 2012
publishDate 2013
url http://irep.iium.edu.my/27869/4/salmiah_v6-712-719.pdf
http://irep.iium.edu.my/27869/
_version_ 1738510087078543360
score 13.160551