Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast
This study was carried out to observe the biocompatibility of gentamicin-coated hydroxyapatite (HA) on osteoblast using fluorescence microscopy. The specific objective was to observe the viability of the osteoblast on the gentamicin-coated hydroxyapatite (HA) and to determine the effect of the bioma...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Putra Malaysia
2010
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/19993/1/Fluorescence_microscopy_on_the_biocompatibility_of_gentamicin-coated_hydroxyapatite_%28HA%29_material_on_osteoblast.pdf http://irep.iium.edu.my/19993/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.iium.irep.19993 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.199932015-04-17T08:32:42Z http://irep.iium.edu.my/19993/ Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast Che Seman, Che Nor Zarida Othman, Fauziah Moin, Saidi Wong, C. C. Besar, Idris Mustaffa, Rusnah Goriman Khan, Mohd Azam Khan Ahmad, Azfar Rizal Zulkifly, Ahmad Hafiz RD701 Orthopedics This study was carried out to observe the biocompatibility of gentamicin-coated hydroxyapatite (HA) on osteoblast using fluorescence microscopy. The specific objective was to observe the viability of the osteoblast on the gentamicin-coated hydroxyapatite (HA) and to determine the effect of the biomaterial coated with gentamicin on the osteoblast. Osteoblast cell lines were cultured and maintained in complete medium, 1:1 HAM's F12 Medium Dulbecco's modified Eagle's medium without phenol red (DMEM) and incubated at 37°C in a 5% CO2. The cell lines were treated with different concentration of gentamicin-coated hydroxyapatite and the interactions of the antibiotic beads against osteoblast were tested using the 3-(4, 5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The MTT assay results indicated that varying concentrations of gentamicin coated HA from 0.1 mg/ml to 10 mg/ml did not significantly affect viability of osteoblast. By employing fluorescence microscopy, the morphology of osteoblast observed appeared red in color which indicated that the osteoblast was viable on biomaterial. The pore size of hydroxyapatite is between 150 to 350 nm. This preliminary result suggested that the gentamicin-coated HA had a good biocompatibility towards osteoblast. Universiti Putra Malaysia 2010 Article REM application/pdf en http://irep.iium.edu.my/19993/1/Fluorescence_microscopy_on_the_biocompatibility_of_gentamicin-coated_hydroxyapatite_%28HA%29_material_on_osteoblast.pdf Che Seman, Che Nor Zarida and Othman, Fauziah and Moin, Saidi and Wong, C. C. and Besar, Idris and Mustaffa, Rusnah and Goriman Khan, Mohd Azam Khan and Ahmad, Azfar Rizal and Zulkifly, Ahmad Hafiz (2010) Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast. Malaysian Journal of Microscopy, 6 (1). pp. 1-8. ISSN 1823-7010 |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
RD701 Orthopedics |
spellingShingle |
RD701 Orthopedics Che Seman, Che Nor Zarida Othman, Fauziah Moin, Saidi Wong, C. C. Besar, Idris Mustaffa, Rusnah Goriman Khan, Mohd Azam Khan Ahmad, Azfar Rizal Zulkifly, Ahmad Hafiz Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast |
description |
This study was carried out to observe the biocompatibility of gentamicin-coated hydroxyapatite (HA) on osteoblast using fluorescence microscopy. The specific objective was to observe the viability of the osteoblast on the gentamicin-coated hydroxyapatite (HA) and to determine the effect of the biomaterial coated with gentamicin on the osteoblast. Osteoblast cell lines were cultured and maintained in complete medium, 1:1 HAM's F12 Medium Dulbecco's modified Eagle's medium without phenol red (DMEM) and incubated at 37°C in a 5% CO2. The cell lines were treated with different concentration of gentamicin-coated hydroxyapatite and the interactions of the antibiotic beads against osteoblast were tested using the 3-(4, 5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The MTT assay results indicated that varying concentrations of gentamicin coated HA from 0.1 mg/ml to 10 mg/ml did not significantly affect viability of osteoblast. By employing fluorescence microscopy, the morphology of osteoblast observed appeared red in color which indicated that the osteoblast was viable on biomaterial. The pore size of hydroxyapatite is between 150 to 350 nm. This preliminary result suggested that the gentamicin-coated HA had a good biocompatibility towards osteoblast. |
format |
Article |
author |
Che Seman, Che Nor Zarida Othman, Fauziah Moin, Saidi Wong, C. C. Besar, Idris Mustaffa, Rusnah Goriman Khan, Mohd Azam Khan Ahmad, Azfar Rizal Zulkifly, Ahmad Hafiz |
author_facet |
Che Seman, Che Nor Zarida Othman, Fauziah Moin, Saidi Wong, C. C. Besar, Idris Mustaffa, Rusnah Goriman Khan, Mohd Azam Khan Ahmad, Azfar Rizal Zulkifly, Ahmad Hafiz |
author_sort |
Che Seman, Che Nor Zarida |
title |
Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast |
title_short |
Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast |
title_full |
Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast |
title_fullStr |
Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast |
title_full_unstemmed |
Fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (HA) material on osteoblast |
title_sort |
fluorescence microscopy on the biocompatibility of gentamicin-coated hydroxyapatite (ha) material on osteoblast |
publisher |
Universiti Putra Malaysia |
publishDate |
2010 |
url |
http://irep.iium.edu.my/19993/1/Fluorescence_microscopy_on_the_biocompatibility_of_gentamicin-coated_hydroxyapatite_%28HA%29_material_on_osteoblast.pdf http://irep.iium.edu.my/19993/ |
_version_ |
1643607804720709632 |
score |
13.211869 |