Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system

Temperature control is important in energy management of buildings. Air conditioning system contributes a high percentage of the total energy consumption, the compressor, which is a major component of the Air conditioning system, utilizes up to 90% of the energy. This can drastically be reduced by v...

Full description

Saved in:
Bibliographic Details
Main Authors: Oleolo, Ibrahim, Abdullah, Hayati, Mustapha, Ismail, Mohamad, Maziah, Mohd Jaafar, Mohammad Nazri, Olowolayemo, Akeem, Sulaiman, Sapiah
Format: Article
Language:English
English
Published: Semarak Ilmu Publishing 2022
Subjects:
Online Access:http://irep.iium.edu.my/101682/7/101682_Long%20short-term%20memory%20neural%20network_SCOPUS.pdf
http://irep.iium.edu.my/101682/8/101682_Long%20short-term%20memory%20neural%20network.pdf
http://irep.iium.edu.my/101682/
https://semarakilmu.com.my/journals/index.php/CFD_Letters/article/view/1287/739
https://doi.org/10.37934/cfdl.14.12.8498
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.101682
record_format dspace
spelling my.iium.irep.1016822022-12-06T02:29:27Z http://irep.iium.edu.my/101682/ Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system Oleolo, Ibrahim Abdullah, Hayati Mustapha, Ismail Mohamad, Maziah Mohd Jaafar, Mohammad Nazri Olowolayemo, Akeem Sulaiman, Sapiah TK4601 Electric heating Temperature control is important in energy management of buildings. Air conditioning system contributes a high percentage of the total energy consumption, the compressor, which is a major component of the Air conditioning system, utilizes up to 90% of the energy. This can drastically be reduced by varying the frequency of the compressor with respect to the required indoor temperature, as such, reducing the overall energy usage of the air conditioning system. The combination of a well-tuned controller and variable frequency drive can be used to achieve this. It is important to develop a good model which can be used to design the controller. Although there are published research works in the development of models for the control of air conditioning systems, there seems to be a lack of study in the area of multi-circuit centralized air conditioning system. In this study, two models were developed using Long Short Term Memory Neural Network and Recurrent Neural Network, utilizing compressor speed and indoor air temperature of a multi-circuit water cooled packaged unit as input and output respectively. Comparing the two models, results shows that the Long Short-Term Memory Neural Network model performed better across evaluation metrics such as R-squared, Mean Squared Error and Mean Absolute Error, with the value of 0.9638, 0.0049, and 0.0190 respectively. Semarak Ilmu Publishing 2022-11-22 Article PeerReviewed application/pdf en http://irep.iium.edu.my/101682/7/101682_Long%20short-term%20memory%20neural%20network_SCOPUS.pdf application/pdf en http://irep.iium.edu.my/101682/8/101682_Long%20short-term%20memory%20neural%20network.pdf Oleolo, Ibrahim and Abdullah, Hayati and Mustapha, Ismail and Mohamad, Maziah and Mohd Jaafar, Mohammad Nazri and Olowolayemo, Akeem and Sulaiman, Sapiah (2022) Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system. CFD Letters, 14 (12). pp. 84-98. ISSN 2180-1363 https://semarakilmu.com.my/journals/index.php/CFD_Letters/article/view/1287/739 https://doi.org/10.37934/cfdl.14.12.8498
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic TK4601 Electric heating
spellingShingle TK4601 Electric heating
Oleolo, Ibrahim
Abdullah, Hayati
Mustapha, Ismail
Mohamad, Maziah
Mohd Jaafar, Mohammad Nazri
Olowolayemo, Akeem
Sulaiman, Sapiah
Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system
description Temperature control is important in energy management of buildings. Air conditioning system contributes a high percentage of the total energy consumption, the compressor, which is a major component of the Air conditioning system, utilizes up to 90% of the energy. This can drastically be reduced by varying the frequency of the compressor with respect to the required indoor temperature, as such, reducing the overall energy usage of the air conditioning system. The combination of a well-tuned controller and variable frequency drive can be used to achieve this. It is important to develop a good model which can be used to design the controller. Although there are published research works in the development of models for the control of air conditioning systems, there seems to be a lack of study in the area of multi-circuit centralized air conditioning system. In this study, two models were developed using Long Short Term Memory Neural Network and Recurrent Neural Network, utilizing compressor speed and indoor air temperature of a multi-circuit water cooled packaged unit as input and output respectively. Comparing the two models, results shows that the Long Short-Term Memory Neural Network model performed better across evaluation metrics such as R-squared, Mean Squared Error and Mean Absolute Error, with the value of 0.9638, 0.0049, and 0.0190 respectively.
format Article
author Oleolo, Ibrahim
Abdullah, Hayati
Mustapha, Ismail
Mohamad, Maziah
Mohd Jaafar, Mohammad Nazri
Olowolayemo, Akeem
Sulaiman, Sapiah
author_facet Oleolo, Ibrahim
Abdullah, Hayati
Mustapha, Ismail
Mohamad, Maziah
Mohd Jaafar, Mohammad Nazri
Olowolayemo, Akeem
Sulaiman, Sapiah
author_sort Oleolo, Ibrahim
title Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system
title_short Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system
title_full Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system
title_fullStr Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system
title_full_unstemmed Long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system
title_sort long short-term memory neural network model for the control of temperature in a multi-circuit air conditioning system
publisher Semarak Ilmu Publishing
publishDate 2022
url http://irep.iium.edu.my/101682/7/101682_Long%20short-term%20memory%20neural%20network_SCOPUS.pdf
http://irep.iium.edu.my/101682/8/101682_Long%20short-term%20memory%20neural%20network.pdf
http://irep.iium.edu.my/101682/
https://semarakilmu.com.my/journals/index.php/CFD_Letters/article/view/1287/739
https://doi.org/10.37934/cfdl.14.12.8498
_version_ 1751535951748792320
score 13.211869