Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique.

Packed towers are used in many unit operations such as absorption, extraction, distillation, humidification and hydrotreating reactors. Liquid flows down the packed bed by gravity over the packing elements to create gas-liquid / liquid-solid contact area for mass transfer across the phases. Ratio of...

Full description

Saved in:
Bibliographic Details
Main Author: Azmi, Muhammad Izzat
Format: Final Year Project
Language:English
Published: Universiti Teknologi PETRONAS 2013
Subjects:
Online Access:http://utpedia.utp.edu.my/8450/1/FYP%20FINAL%20DISSERTATION%20MUHAMMAD%20IZZAT%20BIN%20AZMI%2012748.pdf
http://utpedia.utp.edu.my/8450/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.8450
record_format eprints
spelling my-utp-utpedia.84502013-10-09T11:07:21Z http://utpedia.utp.edu.my/8450/ Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique. Azmi, Muhammad Izzat TP Chemical technology Packed towers are used in many unit operations such as absorption, extraction, distillation, humidification and hydrotreating reactors. Liquid flows down the packed bed by gravity over the packing elements to create gas-liquid / liquid-solid contact area for mass transfer across the phases. Ratio of gas-liquid area to surface area of packing element is known as effective interfacial area; ratio of liquid solid contact area to surface area of packing elements is known as wetting efficiency. Efficiency of a packed tower depends on the wetting efficiency of packing elements. Many researchers investigated wetting efficiency in packed towers. Yet there is still no reliable scientific basis to accurately estimate wetting efficiency. In this investigation, available literature information on wetting efficiency in a packed tower is reviewed and experimentally measured using stimulus response technique of pulse input at three different flow rates using RTD Studies in Packed Bed equipment. The result obtained is compared with other literature data. Through experimental data simple model for estimating wetting efficiency is developed. However further refinement of equation is needed for better accuracy. The data are analysed through a rivulet flow model. Universiti Teknologi PETRONAS 2013-05 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/8450/1/FYP%20FINAL%20DISSERTATION%20MUHAMMAD%20IZZAT%20BIN%20AZMI%2012748.pdf Azmi, Muhammad Izzat (2013) Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique. Universiti Teknologi PETRONAS. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Azmi, Muhammad Izzat
Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique.
description Packed towers are used in many unit operations such as absorption, extraction, distillation, humidification and hydrotreating reactors. Liquid flows down the packed bed by gravity over the packing elements to create gas-liquid / liquid-solid contact area for mass transfer across the phases. Ratio of gas-liquid area to surface area of packing element is known as effective interfacial area; ratio of liquid solid contact area to surface area of packing elements is known as wetting efficiency. Efficiency of a packed tower depends on the wetting efficiency of packing elements. Many researchers investigated wetting efficiency in packed towers. Yet there is still no reliable scientific basis to accurately estimate wetting efficiency. In this investigation, available literature information on wetting efficiency in a packed tower is reviewed and experimentally measured using stimulus response technique of pulse input at three different flow rates using RTD Studies in Packed Bed equipment. The result obtained is compared with other literature data. Through experimental data simple model for estimating wetting efficiency is developed. However further refinement of equation is needed for better accuracy. The data are analysed through a rivulet flow model.
format Final Year Project
author Azmi, Muhammad Izzat
author_facet Azmi, Muhammad Izzat
author_sort Azmi, Muhammad Izzat
title Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique.
title_short Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique.
title_full Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique.
title_fullStr Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique.
title_full_unstemmed Measurement of Wetting Efficiency in Packed Tower Using Stimulus Response Technique.
title_sort measurement of wetting efficiency in packed tower using stimulus response technique.
publisher Universiti Teknologi PETRONAS
publishDate 2013
url http://utpedia.utp.edu.my/8450/1/FYP%20FINAL%20DISSERTATION%20MUHAMMAD%20IZZAT%20BIN%20AZMI%2012748.pdf
http://utpedia.utp.edu.my/8450/
_version_ 1739831576761466880
score 13.18916