CFD Analysis of Ribbed Double Pipe Beat Exchanger

This study aims at simulating the flow in a ribbed double pipe heat exchanger both numerically and analytically and to analyze the accompanying thermo fluid mechanisms. Two procedures were developed to model the heat transfer and the pressure drop, analytical and numerical. The analytical proced...

Full description

Saved in:
Bibliographic Details
Main Author: Mohamed, Mohamed Fathelrahman
Format: Final Year Project
Language:English
Published: Universiti Teknologi Petronas 2009
Subjects:
Online Access:http://utpedia.utp.edu.my/7697/1/2009%20-%20CFD%20analysis%20of%20ribbed%20double%20pipe%20heat%20exhanger.pdf
http://utpedia.utp.edu.my/7697/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.7697
record_format eprints
spelling my-utp-utpedia.76972017-01-25T09:44:28Z http://utpedia.utp.edu.my/7697/ CFD Analysis of Ribbed Double Pipe Beat Exchanger Mohamed, Mohamed Fathelrahman TJ Mechanical engineering and machinery This study aims at simulating the flow in a ribbed double pipe heat exchanger both numerically and analytically and to analyze the accompanying thermo fluid mechanisms. Two procedures were developed to model the heat transfer and the pressure drop, analytical and numerical. The analytical procedure employs empirical equations and correlations governing the flow. The equations were compiled in a MATLAB code to be solved. The numerical procedure is based on simulating the flow using FLUNET to obtain details of the velocity, temperature and pressure distribution across the flow channel. These values were then used to evaluate the friction fuctor and Stanton number from their fundamental relations using MATLAB The results from both procedures showed good agreement with the experimental results. At a Reynolds number range of 2000-20,000 , heat transfer was found to be enhanced by more than 4 times at an expense of increasing pressure drop of more than 26 times. Universiti Teknologi Petronas 2009 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/7697/1/2009%20-%20CFD%20analysis%20of%20ribbed%20double%20pipe%20heat%20exhanger.pdf Mohamed, Mohamed Fathelrahman (2009) CFD Analysis of Ribbed Double Pipe Beat Exchanger. Universiti Teknologi Petronas. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Mohamed, Mohamed Fathelrahman
CFD Analysis of Ribbed Double Pipe Beat Exchanger
description This study aims at simulating the flow in a ribbed double pipe heat exchanger both numerically and analytically and to analyze the accompanying thermo fluid mechanisms. Two procedures were developed to model the heat transfer and the pressure drop, analytical and numerical. The analytical procedure employs empirical equations and correlations governing the flow. The equations were compiled in a MATLAB code to be solved. The numerical procedure is based on simulating the flow using FLUNET to obtain details of the velocity, temperature and pressure distribution across the flow channel. These values were then used to evaluate the friction fuctor and Stanton number from their fundamental relations using MATLAB The results from both procedures showed good agreement with the experimental results. At a Reynolds number range of 2000-20,000 , heat transfer was found to be enhanced by more than 4 times at an expense of increasing pressure drop of more than 26 times.
format Final Year Project
author Mohamed, Mohamed Fathelrahman
author_facet Mohamed, Mohamed Fathelrahman
author_sort Mohamed, Mohamed Fathelrahman
title CFD Analysis of Ribbed Double Pipe Beat Exchanger
title_short CFD Analysis of Ribbed Double Pipe Beat Exchanger
title_full CFD Analysis of Ribbed Double Pipe Beat Exchanger
title_fullStr CFD Analysis of Ribbed Double Pipe Beat Exchanger
title_full_unstemmed CFD Analysis of Ribbed Double Pipe Beat Exchanger
title_sort cfd analysis of ribbed double pipe beat exchanger
publisher Universiti Teknologi Petronas
publishDate 2009
url http://utpedia.utp.edu.my/7697/1/2009%20-%20CFD%20analysis%20of%20ribbed%20double%20pipe%20heat%20exhanger.pdf
http://utpedia.utp.edu.my/7697/
_version_ 1739831497899114496
score 13.211869