MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY

In many medical applications, the medicine or water needs to be infused over a period oftime. The systems also need fully involvement from the physician to monitor the delivery rate and control the amount of rate by adjusting the device manually. Most of the delivery system is an open loop system...

Full description

Saved in:
Bibliographic Details
Main Author: ABDUL GHANI, AIDA NURNAZIFA
Format: Final Year Project
Language:English
Published: Universiti Teknologi Petronas 2005
Online Access:http://utpedia.utp.edu.my/7677/1/2005%20-%20MEDICINEWATER%20DELIVERY%20SYSTEM%20WITH%20RESPONSE%20TO%20CHANGES%20IN%20PATIENT%27S%20BODY.pdf
http://utpedia.utp.edu.my/7677/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.7677
record_format eprints
spelling my-utp-utpedia.76772017-01-25T09:46:27Z http://utpedia.utp.edu.my/7677/ MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY ABDUL GHANI, AIDA NURNAZIFA In many medical applications, the medicine or water needs to be infused over a period oftime. The systems also need fully involvement from the physician to monitor the delivery rate and control the amount of rate by adjusting the device manually. Most of the delivery system is an open loop system where the rate is set basis of the past experience, mathematical computation and trial and error. This might lead to the human error with wrong collected data such as mistake in decimal place dose. Based on the problems, this project is done to replace and enhance the open loop systems by using the automated closed loop system. Basically, this project is to create a medicine delivery system with response to changes in patient's body. The change in patient's body is referred to the temperature. Basically, athermistor sensor is used to detect the changes in the temperature by placing it at the human skin. Then, the signal from the sensor is sent to the PIC microcontroller to control the medicine delivery by automatically adjusting the pump movement. The microcontroller evaluates the received signal and displays the value in degree Celsius on the LCD display. The overall delivery system is fully automated controlled by the controller which depends onthe human body temperature changes. Universiti Teknologi Petronas 2005-12 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/7677/1/2005%20-%20MEDICINEWATER%20DELIVERY%20SYSTEM%20WITH%20RESPONSE%20TO%20CHANGES%20IN%20PATIENT%27S%20BODY.pdf ABDUL GHANI, AIDA NURNAZIFA (2005) MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY. Universiti Teknologi Petronas. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
description In many medical applications, the medicine or water needs to be infused over a period oftime. The systems also need fully involvement from the physician to monitor the delivery rate and control the amount of rate by adjusting the device manually. Most of the delivery system is an open loop system where the rate is set basis of the past experience, mathematical computation and trial and error. This might lead to the human error with wrong collected data such as mistake in decimal place dose. Based on the problems, this project is done to replace and enhance the open loop systems by using the automated closed loop system. Basically, this project is to create a medicine delivery system with response to changes in patient's body. The change in patient's body is referred to the temperature. Basically, athermistor sensor is used to detect the changes in the temperature by placing it at the human skin. Then, the signal from the sensor is sent to the PIC microcontroller to control the medicine delivery by automatically adjusting the pump movement. The microcontroller evaluates the received signal and displays the value in degree Celsius on the LCD display. The overall delivery system is fully automated controlled by the controller which depends onthe human body temperature changes.
format Final Year Project
author ABDUL GHANI, AIDA NURNAZIFA
spellingShingle ABDUL GHANI, AIDA NURNAZIFA
MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY
author_facet ABDUL GHANI, AIDA NURNAZIFA
author_sort ABDUL GHANI, AIDA NURNAZIFA
title MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY
title_short MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY
title_full MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY
title_fullStr MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY
title_full_unstemmed MEDICINE/WATER DELIVERY SYSTEM WITH RESPONSE TO CHANGES IN PATIENT'S BODY
title_sort medicine/water delivery system with response to changes in patient's body
publisher Universiti Teknologi Petronas
publishDate 2005
url http://utpedia.utp.edu.my/7677/1/2005%20-%20MEDICINEWATER%20DELIVERY%20SYSTEM%20WITH%20RESPONSE%20TO%20CHANGES%20IN%20PATIENT%27S%20BODY.pdf
http://utpedia.utp.edu.my/7677/
_version_ 1739831495233634304
score 13.214268