The objective ofthis project is to study and find the optimum factors such as pH, temperature and microbial nutrients that affect the performance of the sewage treatment plant. The problem to the project is to minimize the value ofBiological Oxygen Demand (BOD) of an activated sludge sewage trea...

Full description

Saved in:
Bibliographic Details
Main Author: Ang , Yi Ching
Format: Final Year Project
Language:English
Published: Universiti Teknologi Petronas 2004
Subjects:
Online Access:http://utpedia.utp.edu.my/7250/1/2004%20-%20Factors%20Affecting%20Performance%20of%20Sewage%20Treatment%20Plant.pdf
http://utpedia.utp.edu.my/7250/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.7250
record_format eprints
spelling my-utp-utpedia.72502017-01-25T09:47:10Z http://utpedia.utp.edu.my/7250/ Factors Affecting Performance of Sewage Treatment Plant Ang , Yi Ching TP Chemical technology The objective ofthis project is to study and find the optimum factors such as pH, temperature and microbial nutrients that affect the performance of the sewage treatment plant. The problem to the project is to minimize the value ofBiological Oxygen Demand (BOD) of an activated sludge sewage treatment plant. The effluent of a treatment plant should meet the requirements ofEnvironmental Quality (Sewage and Industrial Effluents) Regulations 1979. The scope ofthis project would be limited to the aeration tank. Although there are many other factors that can affect the performance of the treatment plant, pH, temperature and microbial nutrients are identified for analysis. In order to find the optimum conditions for a wastewater treatment plant, a multi national company is identified as my case study. Then, literature reviews on the activated sludge and other related issues are conducted to obtain background information and previous study. Experimental works was carried out to determine the value of Biochemical Oxygen Demand (BOD) using BODTrak and Chemical Oxygen Demand (COD) using digestion method. The analysis is conducted before and after the treatment at the aeration tank. The data gathered from the experiments is then further analyzed in terms of performance or percentage reduction ofBOD value. It is found out that the optimum conditions for the BOD removal is at temperature between 30°C to 31°C and pHof 7.5. The amount of Total Organic Carbon should be higher than 50mg/L with the ratio of Carbon:Nitrogen:Phosphorus of 100:10:1. All these are the nutrients for the synthesis of microorganisms in the treatment plant. Universiti Teknologi Petronas 2004-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/7250/1/2004%20-%20Factors%20Affecting%20Performance%20of%20Sewage%20Treatment%20Plant.pdf Ang , Yi Ching (2004) Factors Affecting Performance of Sewage Treatment Plant. Universiti Teknologi Petronas. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Ang , Yi Ching
Factors Affecting Performance of Sewage Treatment Plant
description The objective ofthis project is to study and find the optimum factors such as pH, temperature and microbial nutrients that affect the performance of the sewage treatment plant. The problem to the project is to minimize the value ofBiological Oxygen Demand (BOD) of an activated sludge sewage treatment plant. The effluent of a treatment plant should meet the requirements ofEnvironmental Quality (Sewage and Industrial Effluents) Regulations 1979. The scope ofthis project would be limited to the aeration tank. Although there are many other factors that can affect the performance of the treatment plant, pH, temperature and microbial nutrients are identified for analysis. In order to find the optimum conditions for a wastewater treatment plant, a multi national company is identified as my case study. Then, literature reviews on the activated sludge and other related issues are conducted to obtain background information and previous study. Experimental works was carried out to determine the value of Biochemical Oxygen Demand (BOD) using BODTrak and Chemical Oxygen Demand (COD) using digestion method. The analysis is conducted before and after the treatment at the aeration tank. The data gathered from the experiments is then further analyzed in terms of performance or percentage reduction ofBOD value. It is found out that the optimum conditions for the BOD removal is at temperature between 30°C to 31°C and pHof 7.5. The amount of Total Organic Carbon should be higher than 50mg/L with the ratio of Carbon:Nitrogen:Phosphorus of 100:10:1. All these are the nutrients for the synthesis of microorganisms in the treatment plant.
format Final Year Project
author Ang , Yi Ching
author_facet Ang , Yi Ching
author_sort Ang , Yi Ching
title Factors Affecting Performance of Sewage Treatment Plant
title_short Factors Affecting Performance of Sewage Treatment Plant
title_full Factors Affecting Performance of Sewage Treatment Plant
title_fullStr Factors Affecting Performance of Sewage Treatment Plant
title_full_unstemmed Factors Affecting Performance of Sewage Treatment Plant
title_sort factors affecting performance of sewage treatment plant
publisher Universiti Teknologi Petronas
publishDate 2004
url http://utpedia.utp.edu.my/7250/1/2004%20-%20Factors%20Affecting%20Performance%20of%20Sewage%20Treatment%20Plant.pdf
http://utpedia.utp.edu.my/7250/
_version_ 1739831440186540032
score 13.211869