IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK

This project will cover the study in EMI analysis of integrated RCD and RLD type of snubber network in a 100W50 kHz buck converter. The purpose of this study is to improve the efficiency and to reduce the EMI conducted emission in the circuit. A comparison of EMI conducted emission and efficiency...

Full description

Saved in:
Bibliographic Details
Main Author: MUHAMAD, MAJIDAH
Format: Final Year Project
Language:English
Published: Universiti Teknologi Petronas 2006
Subjects:
Online Access:http://utpedia.utp.edu.my/7010/1/2006%20-%20IMPROVEMENT%20STUDY%20OF%20EMI%20ANALYSIS%20IN%20DC-DC%20BUCK%20CONVERTER%20USING%20RCD-RLD%20SNUBBER%20NETWORK.pdf
http://utpedia.utp.edu.my/7010/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.7010
record_format eprints
spelling my-utp-utpedia.70102017-01-25T09:46:03Z http://utpedia.utp.edu.my/7010/ IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK MUHAMAD, MAJIDAH TK Electrical engineering. Electronics Nuclear engineering This project will cover the study in EMI analysis of integrated RCD and RLD type of snubber network in a 100W50 kHz buck converter. The purpose of this study is to improve the efficiency and to reduce the EMI conducted emission in the circuit. A comparison of EMI conducted emission and efficiency in buck converterwith various snubbers is included. In this paper, the integratedRCD and RLD snubber circuit is effectively reduce the EMI conducted emission. However, the efficiency of the circuit is still at low level. To improve the efficiency of this circuit, a combination of synchronous rectifier, parallel Schottky diode and integrated RCD and RLD type of snubber network is proposed. The desired results are not achieved because the proposed component is not available in PSPICE library. Another alternative is presented by increasing the load resistor. From this method, the efficiency of the circuit with integrated RCD and RLD snubber after improvement is 2.63% higher than the converter without snubber and 1.92% higher than the converter with RCD+RLD snubber before improvement. For EMI, the circuit after improvement could reduce 6.14 dBuV less than the circuit without snubber and 0.88 dBuV less than the circuit before improvement. Universiti Teknologi Petronas 2006-12 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/7010/1/2006%20-%20IMPROVEMENT%20STUDY%20OF%20EMI%20ANALYSIS%20IN%20DC-DC%20BUCK%20CONVERTER%20USING%20RCD-RLD%20SNUBBER%20NETWORK.pdf MUHAMAD, MAJIDAH (2006) IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK. Universiti Teknologi Petronas. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
MUHAMAD, MAJIDAH
IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK
description This project will cover the study in EMI analysis of integrated RCD and RLD type of snubber network in a 100W50 kHz buck converter. The purpose of this study is to improve the efficiency and to reduce the EMI conducted emission in the circuit. A comparison of EMI conducted emission and efficiency in buck converterwith various snubbers is included. In this paper, the integratedRCD and RLD snubber circuit is effectively reduce the EMI conducted emission. However, the efficiency of the circuit is still at low level. To improve the efficiency of this circuit, a combination of synchronous rectifier, parallel Schottky diode and integrated RCD and RLD type of snubber network is proposed. The desired results are not achieved because the proposed component is not available in PSPICE library. Another alternative is presented by increasing the load resistor. From this method, the efficiency of the circuit with integrated RCD and RLD snubber after improvement is 2.63% higher than the converter without snubber and 1.92% higher than the converter with RCD+RLD snubber before improvement. For EMI, the circuit after improvement could reduce 6.14 dBuV less than the circuit without snubber and 0.88 dBuV less than the circuit before improvement.
format Final Year Project
author MUHAMAD, MAJIDAH
author_facet MUHAMAD, MAJIDAH
author_sort MUHAMAD, MAJIDAH
title IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK
title_short IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK
title_full IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK
title_fullStr IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK
title_full_unstemmed IMPROVEMENT STUDY OF EMI ANALYSIS IN DC-DC BUCK CONVERTER USING RCD-RLD SNUBBER NETWORK
title_sort improvement study of emi analysis in dc-dc buck converter using rcd-rld snubber network
publisher Universiti Teknologi Petronas
publishDate 2006
url http://utpedia.utp.edu.my/7010/1/2006%20-%20IMPROVEMENT%20STUDY%20OF%20EMI%20ANALYSIS%20IN%20DC-DC%20BUCK%20CONVERTER%20USING%20RCD-RLD%20SNUBBER%20NETWORK.pdf
http://utpedia.utp.edu.my/7010/
_version_ 1739831411530006528
score 13.160551