TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING

This report is an energy audit in an oil palm mill by using the IR (infrared) Thermal Imaging system. The energy audit is to evaluate the energy consumption of the plant (oil palm mill) and management of energy. The efficiency of the energy usage can be evaluated and possible recommendation can be p...

Full description

Saved in:
Bibliographic Details
Main Author: Nur Zaihasra Zahari, Nur Zaihasra Zahari
Format: Final Year Project
Language:English
Published: Universiti Teknologi Petronas 2012
Subjects:
Online Access:http://utpedia.utp.edu.my/5602/1/TEMPERATURE%20DISTRIBUTION%20FOR%20PALM%20OIL%20MILL%20USING%20IR%20THERMAL%20IMAGING%28dissertation%29.pdf
http://utpedia.utp.edu.my/5602/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.5602
record_format eprints
spelling my-utp-utpedia.56022017-01-25T09:40:54Z http://utpedia.utp.edu.my/5602/ TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING Nur Zaihasra Zahari, Nur Zaihasra Zahari TJ Mechanical engineering and machinery This report is an energy audit in an oil palm mill by using the IR (infrared) Thermal Imaging system. The energy audit is to evaluate the energy consumption of the plant (oil palm mill) and management of energy. The efficiency of the energy usage can be evaluated and possible recommendation can be proposed to improve the energy consumption of the plant. This energy audit starts with preliminary research to investigate the main factor of the energy consumption by the plant by doing a walk through energy audit. During this visit to the plant, data is gathered and collected. Using the data obtained the recommendation will be proposed according to the result. The methodology that being used in this project can be classify to four main processes. The first processes are the Building and Utility Data Analysis; Walk through Survey, Baseline for Building Energy Use and Evaluation of Energy Saving Measures. This energy audit is done at FELCRA Nasaruddin Palm Oil Mill, Bota, Perak. This energy audit will focus on two main parts of the plant which are the boiler and the turbine (steam generation) that being used to generate the power needed for the plant operation Universiti Teknologi Petronas 2012-05 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/5602/1/TEMPERATURE%20DISTRIBUTION%20FOR%20PALM%20OIL%20MILL%20USING%20IR%20THERMAL%20IMAGING%28dissertation%29.pdf Nur Zaihasra Zahari, Nur Zaihasra Zahari (2012) TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING. Universiti Teknologi Petronas. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Nur Zaihasra Zahari, Nur Zaihasra Zahari
TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING
description This report is an energy audit in an oil palm mill by using the IR (infrared) Thermal Imaging system. The energy audit is to evaluate the energy consumption of the plant (oil palm mill) and management of energy. The efficiency of the energy usage can be evaluated and possible recommendation can be proposed to improve the energy consumption of the plant. This energy audit starts with preliminary research to investigate the main factor of the energy consumption by the plant by doing a walk through energy audit. During this visit to the plant, data is gathered and collected. Using the data obtained the recommendation will be proposed according to the result. The methodology that being used in this project can be classify to four main processes. The first processes are the Building and Utility Data Analysis; Walk through Survey, Baseline for Building Energy Use and Evaluation of Energy Saving Measures. This energy audit is done at FELCRA Nasaruddin Palm Oil Mill, Bota, Perak. This energy audit will focus on two main parts of the plant which are the boiler and the turbine (steam generation) that being used to generate the power needed for the plant operation
format Final Year Project
author Nur Zaihasra Zahari, Nur Zaihasra Zahari
author_facet Nur Zaihasra Zahari, Nur Zaihasra Zahari
author_sort Nur Zaihasra Zahari, Nur Zaihasra Zahari
title TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING
title_short TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING
title_full TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING
title_fullStr TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING
title_full_unstemmed TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING
title_sort temperature distribution for palm oil mill using ir thermal imaging
publisher Universiti Teknologi Petronas
publishDate 2012
url http://utpedia.utp.edu.my/5602/1/TEMPERATURE%20DISTRIBUTION%20FOR%20PALM%20OIL%20MILL%20USING%20IR%20THERMAL%20IMAGING%28dissertation%29.pdf
http://utpedia.utp.edu.my/5602/
_version_ 1739831245102120960
score 13.160551