TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING
This report is an energy audit in an oil palm mill by using the IR (infrared) Thermal Imaging system. The energy audit is to evaluate the energy consumption of the plant (oil palm mill) and management of energy. The efficiency of the energy usage can be evaluated and possible recommendation can be p...
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project |
Language: | English |
Published: |
Universiti Teknologi Petronas
2012
|
Subjects: | |
Online Access: | http://utpedia.utp.edu.my/5602/1/TEMPERATURE%20DISTRIBUTION%20FOR%20PALM%20OIL%20MILL%20USING%20IR%20THERMAL%20IMAGING%28dissertation%29.pdf http://utpedia.utp.edu.my/5602/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utp-utpedia.5602 |
---|---|
record_format |
eprints |
spelling |
my-utp-utpedia.56022017-01-25T09:40:54Z http://utpedia.utp.edu.my/5602/ TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING Nur Zaihasra Zahari, Nur Zaihasra Zahari TJ Mechanical engineering and machinery This report is an energy audit in an oil palm mill by using the IR (infrared) Thermal Imaging system. The energy audit is to evaluate the energy consumption of the plant (oil palm mill) and management of energy. The efficiency of the energy usage can be evaluated and possible recommendation can be proposed to improve the energy consumption of the plant. This energy audit starts with preliminary research to investigate the main factor of the energy consumption by the plant by doing a walk through energy audit. During this visit to the plant, data is gathered and collected. Using the data obtained the recommendation will be proposed according to the result. The methodology that being used in this project can be classify to four main processes. The first processes are the Building and Utility Data Analysis; Walk through Survey, Baseline for Building Energy Use and Evaluation of Energy Saving Measures. This energy audit is done at FELCRA Nasaruddin Palm Oil Mill, Bota, Perak. This energy audit will focus on two main parts of the plant which are the boiler and the turbine (steam generation) that being used to generate the power needed for the plant operation Universiti Teknologi Petronas 2012-05 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/5602/1/TEMPERATURE%20DISTRIBUTION%20FOR%20PALM%20OIL%20MILL%20USING%20IR%20THERMAL%20IMAGING%28dissertation%29.pdf Nur Zaihasra Zahari, Nur Zaihasra Zahari (2012) TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING. Universiti Teknologi Petronas. (Unpublished) |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Electronic and Digitized Intellectual Asset |
url_provider |
http://utpedia.utp.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Nur Zaihasra Zahari, Nur Zaihasra Zahari TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING |
description |
This report is an energy audit in an oil palm mill by using the IR (infrared) Thermal Imaging system. The energy audit is to evaluate the energy consumption of the plant (oil palm mill) and management of energy. The efficiency of the energy usage can be evaluated and possible recommendation can be proposed to improve the energy consumption of the plant.
This energy audit starts with preliminary research to investigate the main factor of the energy consumption by the plant by doing a walk through energy audit. During this visit to the plant, data is gathered and collected. Using the data obtained the recommendation will be proposed according to the result.
The methodology that being used in this project can be classify to four main processes. The first processes are the Building and Utility Data Analysis; Walk through Survey, Baseline for Building Energy Use and Evaluation of Energy Saving Measures. This energy audit is done at FELCRA Nasaruddin Palm Oil Mill, Bota, Perak. This energy audit will focus on two main parts of the plant which are the boiler and the turbine (steam generation) that being used to generate the power needed for the plant operation |
format |
Final Year Project |
author |
Nur Zaihasra Zahari, Nur Zaihasra Zahari |
author_facet |
Nur Zaihasra Zahari, Nur Zaihasra Zahari |
author_sort |
Nur Zaihasra Zahari, Nur Zaihasra Zahari |
title |
TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING |
title_short |
TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING |
title_full |
TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING |
title_fullStr |
TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING |
title_full_unstemmed |
TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING |
title_sort |
temperature distribution for palm oil mill using ir thermal imaging |
publisher |
Universiti Teknologi Petronas |
publishDate |
2012 |
url |
http://utpedia.utp.edu.my/5602/1/TEMPERATURE%20DISTRIBUTION%20FOR%20PALM%20OIL%20MILL%20USING%20IR%20THERMAL%20IMAGING%28dissertation%29.pdf http://utpedia.utp.edu.my/5602/ |
_version_ |
1739831245102120960 |
score |
13.160551 |