The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator
The existence of triplen harmonics in equipment has been recognized dated back in the 19thcentury. Even though many discovery has been made regarding the behavior of triplen harmonics in electrical equipment, many scope still needed to be studied and researched. Thus, the objective of this paper foc...
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project |
Language: | English |
Published: |
Universiti Teknologi PETRONAS
2012
|
Subjects: | |
Online Access: | http://utpedia.utp.edu.my/3964/1/FYP_Final_Report_14067_EE.pdf http://utpedia.utp.edu.my/3964/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utp-utpedia.3964 |
---|---|
record_format |
eprints |
spelling |
my-utp-utpedia.39642017-01-25T09:40:51Z http://utpedia.utp.edu.my/3964/ The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator Mohmad Hamim, Mohd Aizuddin Firdaus bin TK Electrical engineering. Electronics Nuclear engineering The existence of triplen harmonics in equipment has been recognized dated back in the 19thcentury. Even though many discovery has been made regarding the behavior of triplen harmonics in electrical equipment, many scope still needed to be studied and researched. Thus, the objective of this paper focuses on the characteristics of triplen harmonics produced by synchronous generator flowing through various transformer winding configurations subjected to several of load conditions. The scope of experiment for this study covers on the laboratory experiments using lab-scaled salient pole synchronous generator that connects directly to the transformer and load. The transformer has four winding configurations and the load can vary in different resistance and inductance connections in a circuit. Since the third harmonic voltage produced by generator are in phase or zero sequence in nature, the third harmonic current depend on transformer winding configuration, the load impedance magnitude and phase angle. In conclusion, this study provides a very important knowledge regarding the third harmonic flowing through transformer. Different kinds of transformer winding configuration have their own characteristic. Third harmonic voltage and current magnitude alone may not give correct indication to their severity because they are vector quantity and rely on zero sequence network, load impedance magnitude and phase angle. Universiti Teknologi PETRONAS 2012-05 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/3964/1/FYP_Final_Report_14067_EE.pdf Mohmad Hamim, Mohd Aizuddin Firdaus bin (2012) The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator. Universiti Teknologi PETRONAS. |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Electronic and Digitized Intellectual Asset |
url_provider |
http://utpedia.utp.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Mohmad Hamim, Mohd Aizuddin Firdaus bin The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator |
description |
The existence of triplen harmonics in equipment has been recognized dated back in the 19thcentury. Even though many discovery has been made regarding the behavior of triplen harmonics in electrical equipment, many scope still needed to be studied and researched. Thus, the objective of this paper focuses on the characteristics of triplen harmonics produced by synchronous generator flowing through various transformer winding configurations subjected to several of load conditions. The scope of experiment for this study covers on the laboratory experiments using lab-scaled salient pole synchronous generator that connects directly to the transformer and load. The transformer has four winding configurations and the load can vary in different resistance and inductance connections in a circuit. Since the third harmonic voltage produced by generator are in phase or zero sequence in nature, the third harmonic current depend on transformer winding configuration, the load impedance magnitude and phase angle. In conclusion, this study provides a very important knowledge regarding the third harmonic flowing through transformer. Different kinds of transformer winding configuration have their own characteristic. Third harmonic voltage and current magnitude alone may not give correct indication to their severity because they are vector quantity and rely on zero sequence network, load impedance magnitude and phase angle. |
format |
Final Year Project |
author |
Mohmad Hamim, Mohd Aizuddin Firdaus bin |
author_facet |
Mohmad Hamim, Mohd Aizuddin Firdaus bin |
author_sort |
Mohmad Hamim, Mohd Aizuddin Firdaus bin |
title |
The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator |
title_short |
The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator |
title_full |
The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator |
title_fullStr |
The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator |
title_full_unstemmed |
The Influence of Transformer Winding Configuration on Triplen Harmonic Produced by Synchronous Generator |
title_sort |
influence of transformer winding configuration on triplen harmonic produced by synchronous generator |
publisher |
Universiti Teknologi PETRONAS |
publishDate |
2012 |
url |
http://utpedia.utp.edu.my/3964/1/FYP_Final_Report_14067_EE.pdf http://utpedia.utp.edu.my/3964/ |
_version_ |
1739831093023997952 |
score |
13.160551 |