WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER

Electrical transmission line is it medium to carry power loads from one station to another station, therefore, it is one of the most important projects in power business. To maintain the reliability and safety of' the structure, the dynamic and static load acting on transmission structure s...

Full description

Saved in:
Bibliographic Details
Main Author: PAUZI, FATIN HANANI
Format: Final Year Project
Language:English
Published: 2010
Online Access:http://utpedia.utp.edu.my/2971/1/0001.pdf
http://utpedia.utp.edu.my/2971/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.2971
record_format eprints
spelling my-utp-utpedia.29712017-01-25T09:42:55Z http://utpedia.utp.edu.my/2971/ WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER PAUZI, FATIN HANANI Electrical transmission line is it medium to carry power loads from one station to another station, therefore, it is one of the most important projects in power business. To maintain the reliability and safety of' the structure, the dynamic and static load acting on transmission structure should be thoroughly studied before an efficient design may be obtained. I ligh standard of design to cater effect of wind load must be implemented to preclude any structural Ihilure which will interrupt the national grid supply of power. The main objective of this study is to identify the behavior of electrical transmission tower due to lateral wind forces. In addition, this study aims to evaluate current design practice adopted by Tenaga Nasional Berhad (TNB) on its adequacy and in optimization of their design. The study begins with comprehensive research and literature review on behavior of transmission tower and conductor under wind loads. A 132kV electrical transmission tower is identified for the purpose of analysis. The calculation of design wind loads are in accordance with American Society of* Civil Engineers (ASCE) 7-05 Minimum Design Loads for Building and Other Structures. The electrical transmission tower is assumed located at mountainous area with it wind speed of' 38 m/s and assessed as a global structure under normal situation as well as under broken conductor situation. As the outcome of the analysis, it design assessment of the transmission tower is provided. Subsequently, the reliability of' TNB current practice of design and the design adequacy is evaluated. 2010-06 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/2971/1/0001.pdf PAUZI, FATIN HANANI (2010) WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER. UNSPECIFIED. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
description Electrical transmission line is it medium to carry power loads from one station to another station, therefore, it is one of the most important projects in power business. To maintain the reliability and safety of' the structure, the dynamic and static load acting on transmission structure should be thoroughly studied before an efficient design may be obtained. I ligh standard of design to cater effect of wind load must be implemented to preclude any structural Ihilure which will interrupt the national grid supply of power. The main objective of this study is to identify the behavior of electrical transmission tower due to lateral wind forces. In addition, this study aims to evaluate current design practice adopted by Tenaga Nasional Berhad (TNB) on its adequacy and in optimization of their design. The study begins with comprehensive research and literature review on behavior of transmission tower and conductor under wind loads. A 132kV electrical transmission tower is identified for the purpose of analysis. The calculation of design wind loads are in accordance with American Society of* Civil Engineers (ASCE) 7-05 Minimum Design Loads for Building and Other Structures. The electrical transmission tower is assumed located at mountainous area with it wind speed of' 38 m/s and assessed as a global structure under normal situation as well as under broken conductor situation. As the outcome of the analysis, it design assessment of the transmission tower is provided. Subsequently, the reliability of' TNB current practice of design and the design adequacy is evaluated.
format Final Year Project
author PAUZI, FATIN HANANI
spellingShingle PAUZI, FATIN HANANI
WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER
author_facet PAUZI, FATIN HANANI
author_sort PAUZI, FATIN HANANI
title WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER
title_short WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER
title_full WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER
title_fullStr WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER
title_full_unstemmed WIND-STRUCTURE INTERACTION ON TRANSMISSION TOWER
title_sort wind-structure interaction on transmission tower
publishDate 2010
url http://utpedia.utp.edu.my/2971/1/0001.pdf
http://utpedia.utp.edu.my/2971/
_version_ 1739830982954975232
score 13.214268