Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh
A study was conducted into the failure of the heat exchanger. Design of the heat exchanger and operation parameters were scrutinized. In addition, samples of the failed heat exchanger tubes were obtained and studied using various failure analysis tools such as X-ray, optical examination and SEM.
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project |
Language: | English |
Published: |
2008
|
Subjects: | |
Online Access: | http://utpedia.utp.edu.my/249/1/Mohd_Aziman_Bin_Azemi.pdf http://utpedia.utp.edu.my/249/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utp-utpedia.249 |
---|---|
record_format |
eprints |
spelling |
my-utp-utpedia.2492017-01-25T09:45:29Z http://utpedia.utp.edu.my/249/ Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh Mohd Aziman Bin Azemi, Mohd Aziman TJ Mechanical engineering and machinery A study was conducted into the failure of the heat exchanger. Design of the heat exchanger and operation parameters were scrutinized. In addition, samples of the failed heat exchanger tubes were obtained and studied using various failure analysis tools such as X-ray, optical examination and SEM. 2008 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/249/1/Mohd_Aziman_Bin_Azemi.pdf Mohd Aziman Bin Azemi, Mohd Aziman (2008) Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh. UNSPECIFIED. (Unpublished) |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Electronic and Digitized Intellectual Asset |
url_provider |
http://utpedia.utp.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Mohd Aziman Bin Azemi, Mohd Aziman Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh |
description |
A study was conducted into the failure of the heat exchanger. Design of the heat exchanger and operation parameters were scrutinized. In addition, samples of the failed heat exchanger tubes were obtained and studied using various failure analysis tools such as X-ray, optical examination and SEM. |
format |
Final Year Project |
author |
Mohd Aziman Bin Azemi, Mohd Aziman |
author_facet |
Mohd Aziman Bin Azemi, Mohd Aziman |
author_sort |
Mohd Aziman Bin Azemi, Mohd Aziman |
title |
Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh |
title_short |
Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh |
title_full |
Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh |
title_fullStr |
Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh |
title_full_unstemmed |
Failure Analysis of Heat Exchanger’s Tubes at GPP Kerteh |
title_sort |
failure analysis of heat exchanger’s tubes at gpp kerteh |
publishDate |
2008 |
url |
http://utpedia.utp.edu.my/249/1/Mohd_Aziman_Bin_Azemi.pdf http://utpedia.utp.edu.my/249/ |
_version_ |
1739830638853226496 |
score |
13.160551 |