FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS
To ensure transformers still in working condition, it must be tested with few tests. DGA (Dissolve Gas Analysis) test, insulation test, FDS (Frequency Dielectric Spectroscopy) test and etc[1]. As for knowing the condition inside the transformer especially on a transformer core and winding, testing...
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project |
Language: | English |
Published: |
IRC
2019
|
Online Access: | http://utpedia.utp.edu.my/20169/1/MuhammadHusainiFR_23194.pdf http://utpedia.utp.edu.my/20169/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utp-utpedia.20169 |
---|---|
record_format |
eprints |
spelling |
my-utp-utpedia.201692019-12-20T16:13:40Z http://utpedia.utp.edu.my/20169/ FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS ABU HASSAN, MUHAMMAD HUSAINI To ensure transformers still in working condition, it must be tested with few tests. DGA (Dissolve Gas Analysis) test, insulation test, FDS (Frequency Dielectric Spectroscopy) test and etc[1]. As for knowing the condition inside the transformer especially on a transformer core and winding, testing the mechanical condition for both of it, we need FRA test. Frequency Response Analysis (FRA) or Sweep Frequency Response Analysis (SFRA) techniques have been gaining a lot of attention in analyzing the electrical winding and magnetic cores of power transformer throughout this decade[2]. As the test runs and being analyze, the localization of trending of faults is still in a depth of investigation. This research is focus on analyzing 5 testing method on transformer in finding and analyzing short circuit fault in the power transformer. IRC 2019-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/20169/1/MuhammadHusainiFR_23194.pdf ABU HASSAN, MUHAMMAD HUSAINI (2019) FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS. IRC, Universiti Teknologi PETRONAS. (Submitted) |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Electronic and Digitized Intellectual Asset |
url_provider |
http://utpedia.utp.edu.my/ |
language |
English |
description |
To ensure transformers still in working condition, it must be tested with few tests. DGA (Dissolve Gas Analysis) test, insulation test, FDS (Frequency Dielectric Spectroscopy) test and etc[1]. As for knowing the condition inside the transformer especially on a transformer core and winding, testing the mechanical condition for both of it, we need FRA test.
Frequency Response Analysis (FRA) or Sweep Frequency Response Analysis (SFRA) techniques have been gaining a lot of attention in analyzing the electrical winding and magnetic cores of power transformer throughout this decade[2]. As the test runs and being analyze, the localization of trending of faults is still in a depth of investigation. This research is focus on analyzing 5 testing method on transformer in finding and analyzing short circuit fault in the power transformer.
|
format |
Final Year Project |
author |
ABU HASSAN, MUHAMMAD HUSAINI |
spellingShingle |
ABU HASSAN, MUHAMMAD HUSAINI FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS |
author_facet |
ABU HASSAN, MUHAMMAD HUSAINI |
author_sort |
ABU HASSAN, MUHAMMAD HUSAINI |
title |
FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS |
title_short |
FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS |
title_full |
FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS |
title_fullStr |
FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS |
title_full_unstemmed |
FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS |
title_sort |
frequency response analysis for transformers |
publisher |
IRC |
publishDate |
2019 |
url |
http://utpedia.utp.edu.my/20169/1/MuhammadHusainiFR_23194.pdf http://utpedia.utp.edu.my/20169/ |
_version_ |
1739832721658609664 |
score |