CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP)

In any building, window plays an important role for the building’s cooling system. Good positioning and the right amount of window in a specific building will provide the building a good cooling system. In today’s modern era, the evolution of normal window has taken place. These days, window films a...

Full description

Saved in:
Bibliographic Details
Main Author: SHUKRI, FADHIL AIZAD
Format: Final Year Project
Language:English
Published: IRC 2018
Subjects:
Online Access:http://utpedia.utp.edu.my/19276/1/Dissertation_Fadhil%20Aizad%20Bin%20Shukri_20186.pdf
http://utpedia.utp.edu.my/19276/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.19276
record_format eprints
spelling my-utp-utpedia.192762019-06-18T09:34:55Z http://utpedia.utp.edu.my/19276/ CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP) SHUKRI, FADHIL AIZAD TJ Mechanical engineering and machinery In any building, window plays an important role for the building’s cooling system. Good positioning and the right amount of window in a specific building will provide the building a good cooling system. In today’s modern era, the evolution of normal window has taken place. These days, window films are present as a thin layer that can be installed in the interior or exterior part of the window to allow a specific amount of light and heat to go through it, depending on the film’s specifications. Based on pass research, with the installation of window films, the cooling of the building will be more effective with little use of air conditioning power resulting in saving of energy in buildings. In this project, a research will be done on how different types of window films can affect the rate of cooling of the academic buildings in University Technology Petronas (UTP). This project is done by performing simulations using the ANSYS Fluent 18.2 software to observe and analyze on how different window films with different specifications shows the results of the simulations. The window films that were used in this simulation are UTP’s default window films, low emissivity DGU window film, solar control DGU window film and clear float DGU type window film. The U-factor and SGHC value of these window films act as the main manipulating factor for this simulation. The simulated room used in this simulation will be UTP’s academic block 17-03-25 with the air conditioning running at constant velocity. Completing all simulations, it is concluded that the lower U-factor and SGHC value of the windows give better cooling rate for the simulated room. At the end of this project, after done studying and analyzing the data, the most suitable type of window films that should be used in UTP’s academic building can be suggested. IRC 2018-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/19276/1/Dissertation_Fadhil%20Aizad%20Bin%20Shukri_20186.pdf SHUKRI, FADHIL AIZAD (2018) CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP). IRC, Universiti Teknologi PETRONAS. (Submitted)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
SHUKRI, FADHIL AIZAD
CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP)
description In any building, window plays an important role for the building’s cooling system. Good positioning and the right amount of window in a specific building will provide the building a good cooling system. In today’s modern era, the evolution of normal window has taken place. These days, window films are present as a thin layer that can be installed in the interior or exterior part of the window to allow a specific amount of light and heat to go through it, depending on the film’s specifications. Based on pass research, with the installation of window films, the cooling of the building will be more effective with little use of air conditioning power resulting in saving of energy in buildings. In this project, a research will be done on how different types of window films can affect the rate of cooling of the academic buildings in University Technology Petronas (UTP). This project is done by performing simulations using the ANSYS Fluent 18.2 software to observe and analyze on how different window films with different specifications shows the results of the simulations. The window films that were used in this simulation are UTP’s default window films, low emissivity DGU window film, solar control DGU window film and clear float DGU type window film. The U-factor and SGHC value of these window films act as the main manipulating factor for this simulation. The simulated room used in this simulation will be UTP’s academic block 17-03-25 with the air conditioning running at constant velocity. Completing all simulations, it is concluded that the lower U-factor and SGHC value of the windows give better cooling rate for the simulated room. At the end of this project, after done studying and analyzing the data, the most suitable type of window films that should be used in UTP’s academic building can be suggested.
format Final Year Project
author SHUKRI, FADHIL AIZAD
author_facet SHUKRI, FADHIL AIZAD
author_sort SHUKRI, FADHIL AIZAD
title CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP)
title_short CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP)
title_full CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP)
title_fullStr CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP)
title_full_unstemmed CFD STUDY ON EFFECTS OF DIFFERENT WINDOW FILMS ON THE COOLING RATE OF ACADEMIC BUILDINGS IN UNIVERSITY TECHNOLOGY PETRONAS (UTP)
title_sort cfd study on effects of different window films on the cooling rate of academic buildings in university technology petronas (utp)
publisher IRC
publishDate 2018
url http://utpedia.utp.edu.my/19276/1/Dissertation_Fadhil%20Aizad%20Bin%20Shukri_20186.pdf
http://utpedia.utp.edu.my/19276/
_version_ 1739832611653550080
score 13.209306