Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller

Generation of chilled water mostly done using absorption chillers in cooling plant. The application of double effect type chillers are normally be used as it can offer high efficiency compared to single-effect chillers. The COP double-type varies between 0.7 to 1.3. The relation of internal heat inp...

Full description

Saved in:
Bibliographic Details
Main Author: Noor Azman, Muhammad Aiman Faris
Format: Final Year Project
Language:English
Published: 2018
Online Access:http://utpedia.utp.edu.my/19268/1/DISSERTATION%20%28Muhammad%20Aiman%20Faris%20-%2019900%29.pdf
http://utpedia.utp.edu.my/19268/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.19268
record_format eprints
spelling my-utp-utpedia.192682019-06-20T08:19:49Z http://utpedia.utp.edu.my/19268/ Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller Noor Azman, Muhammad Aiman Faris Generation of chilled water mostly done using absorption chillers in cooling plant. The application of double effect type chillers are normally be used as it can offer high efficiency compared to single-effect chillers. The COP double-type varies between 0.7 to 1.3. The relation of internal heat input could give effect to the COP of the chillers. This study was related to the evaluating COP changes with increasing of evaporator performance by using internal operating condition of double effect steam absorption chiller. Operating data for 61 days were used for the study. Duhring double effect schematic diagram was used for developing mass and energy balance equations. Results demonstrated actual COPs were between 1.3 to 1.5 and trends increased simultaneously to the incremental of evaporator performance. From COP outcomes obtained, the results were found to be within the range of COP from other researchers. Due to uncertainty in chiller machine performance, it is recommended to perform economic analysis so that decision can be made whether to replace or keep up the existing absorption chiller. 2018-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/19268/1/DISSERTATION%20%28Muhammad%20Aiman%20Faris%20-%2019900%29.pdf Noor Azman, Muhammad Aiman Faris (2018) Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller. UNSPECIFIED.
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
description Generation of chilled water mostly done using absorption chillers in cooling plant. The application of double effect type chillers are normally be used as it can offer high efficiency compared to single-effect chillers. The COP double-type varies between 0.7 to 1.3. The relation of internal heat input could give effect to the COP of the chillers. This study was related to the evaluating COP changes with increasing of evaporator performance by using internal operating condition of double effect steam absorption chiller. Operating data for 61 days were used for the study. Duhring double effect schematic diagram was used for developing mass and energy balance equations. Results demonstrated actual COPs were between 1.3 to 1.5 and trends increased simultaneously to the incremental of evaporator performance. From COP outcomes obtained, the results were found to be within the range of COP from other researchers. Due to uncertainty in chiller machine performance, it is recommended to perform economic analysis so that decision can be made whether to replace or keep up the existing absorption chiller.
format Final Year Project
author Noor Azman, Muhammad Aiman Faris
spellingShingle Noor Azman, Muhammad Aiman Faris
Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller
author_facet Noor Azman, Muhammad Aiman Faris
author_sort Noor Azman, Muhammad Aiman Faris
title Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller
title_short Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller
title_full Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller
title_fullStr Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller
title_full_unstemmed Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller
title_sort prediction of evaporator performance of double effect steam absorption chiller
publishDate 2018
url http://utpedia.utp.edu.my/19268/1/DISSERTATION%20%28Muhammad%20Aiman%20Faris%20-%2019900%29.pdf
http://utpedia.utp.edu.my/19268/
_version_ 1739832610558836736
score 13.160551