Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings

Prescriptive based approach and the performance based approach are two approaches used in designing a fire sprinkler design system. Alterations on parameters can be done using the performance based approach as calculations are widely implemented thus showing flexibilities, while it is impossible to...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Ali, Syazwani
Format: Final Year Project
Language:English
Published: IRC 2016
Subjects:
Online Access:http://utpedia.utp.edu.my/17235/1/Syazwani%20Binti%20Mohd%20Ali_18597_UTP_Studying%20the%20Parameters%20which%20Affect%20Sprinkler%20Fire%20Protection%20System%20Performance%20in%20Buildings.pdf
http://utpedia.utp.edu.my/17235/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.17235
record_format eprints
spelling my-utp-utpedia.172352017-03-01T16:17:18Z http://utpedia.utp.edu.my/17235/ Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings Mohd Ali, Syazwani TJ Mechanical engineering and machinery Prescriptive based approach and the performance based approach are two approaches used in designing a fire sprinkler design system. Alterations on parameters can be done using the performance based approach as calculations are widely implemented thus showing flexibilities, while it is impossible to alter any parameters using prescriptive based approach as the values of parameters have been predetermined. In this project, the size of the sprinkler system had been reduced and calculations have been done by using a sizing design tool that had been developed. It has been proven that by reducing the size of the system, reduction of cost of installation can be achieved. In this case, the total savings obtained is RM 1.8mil for a 10-storey office building. Even though there are alterations done to the system, it is vital to ensure that the performance of the sprinkler is not affected. The curves of Heat Release Rate (HRR) vs. time for both approaches have been established and compared. The curves were found to not have much difference in the values, indicating that the calculations done to the system are acceptable. IRC 2016-05 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/17235/1/Syazwani%20Binti%20Mohd%20Ali_18597_UTP_Studying%20the%20Parameters%20which%20Affect%20Sprinkler%20Fire%20Protection%20System%20Performance%20in%20Buildings.pdf Mohd Ali, Syazwani (2016) Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings. IRC, Universiti Teknologi PETRONAS. (Submitted)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Mohd Ali, Syazwani
Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings
description Prescriptive based approach and the performance based approach are two approaches used in designing a fire sprinkler design system. Alterations on parameters can be done using the performance based approach as calculations are widely implemented thus showing flexibilities, while it is impossible to alter any parameters using prescriptive based approach as the values of parameters have been predetermined. In this project, the size of the sprinkler system had been reduced and calculations have been done by using a sizing design tool that had been developed. It has been proven that by reducing the size of the system, reduction of cost of installation can be achieved. In this case, the total savings obtained is RM 1.8mil for a 10-storey office building. Even though there are alterations done to the system, it is vital to ensure that the performance of the sprinkler is not affected. The curves of Heat Release Rate (HRR) vs. time for both approaches have been established and compared. The curves were found to not have much difference in the values, indicating that the calculations done to the system are acceptable.
format Final Year Project
author Mohd Ali, Syazwani
author_facet Mohd Ali, Syazwani
author_sort Mohd Ali, Syazwani
title Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings
title_short Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings
title_full Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings
title_fullStr Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings
title_full_unstemmed Studying the Parameters Which Affect Sprinkler Fire Protection System Performance in Buildings
title_sort studying the parameters which affect sprinkler fire protection system performance in buildings
publisher IRC
publishDate 2016
url http://utpedia.utp.edu.my/17235/1/Syazwani%20Binti%20Mohd%20Ali_18597_UTP_Studying%20the%20Parameters%20which%20Affect%20Sprinkler%20Fire%20Protection%20System%20Performance%20in%20Buildings.pdf
http://utpedia.utp.edu.my/17235/
_version_ 1739832359911424000
score 13.214268