Heart Rate Monitoring and Alert System Using Smartphone

Heart disease like arrhythmia need continual long-term monitoring. For example, in emergency at home, where the patient is unable help themselves or seek help, there is a need for long distance health monitoring for early and faster assessment for treatment. This project presents a remote monitoring...

Full description

Saved in:
Bibliographic Details
Main Author: Anuar, Mohamad Syarmie Faizlin
Format: Final Year Project
Language:English
Published: IRC 2016
Subjects:
Online Access:http://utpedia.utp.edu.my/17102/1/Final%20Dissertation.pdf
http://utpedia.utp.edu.my/17102/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.17102
record_format eprints
spelling my-utp-utpedia.171022017-01-25T09:34:29Z http://utpedia.utp.edu.my/17102/ Heart Rate Monitoring and Alert System Using Smartphone Anuar, Mohamad Syarmie Faizlin TK Electrical engineering. Electronics Nuclear engineering Heart disease like arrhythmia need continual long-term monitoring. For example, in emergency at home, where the patient is unable help themselves or seek help, there is a need for long distance health monitoring for early and faster assessment for treatment. This project presents a remote monitoring system for monitoring the irregularity in heart rate, which enables real-time monitoring for the cardiovascular diseases (CVDs) patient. The system utilizes Photoplethysmography (PPG) sensor to obtain the pulse reading. The sensor is non-invasive where pulse reading is taken from the finger. The microcontroller is used to receive and process the signal. When irregularity in heart rate is detected, the microcontroller will send data to a smartphone using Bluetooth. A mobile application is developed to receive the data and to send out an alert in the form of a text message to another mobile phone. The alert is successfully sent to the specified recipient such as medical doctors or next of kin in the emergency which contain the details such as heart rate information and GPS coordinate. Evaluation on the functionality of the device shows that the developed device can reach accuracy of 97.50%, precision of 96.55%, sensitivity of 99.29% and specificity of 91.67%. IRC 2016-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/17102/1/Final%20Dissertation.pdf Anuar, Mohamad Syarmie Faizlin (2016) Heart Rate Monitoring and Alert System Using Smartphone. IRC, Universiti Teknologi PETRONAS. (Submitted)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Anuar, Mohamad Syarmie Faizlin
Heart Rate Monitoring and Alert System Using Smartphone
description Heart disease like arrhythmia need continual long-term monitoring. For example, in emergency at home, where the patient is unable help themselves or seek help, there is a need for long distance health monitoring for early and faster assessment for treatment. This project presents a remote monitoring system for monitoring the irregularity in heart rate, which enables real-time monitoring for the cardiovascular diseases (CVDs) patient. The system utilizes Photoplethysmography (PPG) sensor to obtain the pulse reading. The sensor is non-invasive where pulse reading is taken from the finger. The microcontroller is used to receive and process the signal. When irregularity in heart rate is detected, the microcontroller will send data to a smartphone using Bluetooth. A mobile application is developed to receive the data and to send out an alert in the form of a text message to another mobile phone. The alert is successfully sent to the specified recipient such as medical doctors or next of kin in the emergency which contain the details such as heart rate information and GPS coordinate. Evaluation on the functionality of the device shows that the developed device can reach accuracy of 97.50%, precision of 96.55%, sensitivity of 99.29% and specificity of 91.67%.
format Final Year Project
author Anuar, Mohamad Syarmie Faizlin
author_facet Anuar, Mohamad Syarmie Faizlin
author_sort Anuar, Mohamad Syarmie Faizlin
title Heart Rate Monitoring and Alert System Using Smartphone
title_short Heart Rate Monitoring and Alert System Using Smartphone
title_full Heart Rate Monitoring and Alert System Using Smartphone
title_fullStr Heart Rate Monitoring and Alert System Using Smartphone
title_full_unstemmed Heart Rate Monitoring and Alert System Using Smartphone
title_sort heart rate monitoring and alert system using smartphone
publisher IRC
publishDate 2016
url http://utpedia.utp.edu.my/17102/1/Final%20Dissertation.pdf
http://utpedia.utp.edu.my/17102/
_version_ 1739832345194659840
score 13.160551