Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement

Aboveground atmospheric storage tank is one of the important equipment in plant operation. One of the possible failures which normally overlooked is the failure of the tank due to settlement. The objective of this project is to conduct a deformation analysis based on bending moment theory and finite...

Full description

Saved in:
Bibliographic Details
Main Author: Norhafiza Binti Mohd Zukepeli, Norhafiza
Format: Final Year Project
Language:English
English
Published: Universiti Teknologi Petronas 2010
Subjects:
Online Access:http://utpedia.utp.edu.my/1427/1/Norhafiza_Binti_Mohd_Zukepeli_8064.pdf
http://utpedia.utp.edu.my/1427/4/Quartos_Radintletse_Maremo_Mamabolo.pdf
http://utpedia.utp.edu.my/1427/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.1427
record_format eprints
spelling my-utp-utpedia.14272017-01-25T09:43:40Z http://utpedia.utp.edu.my/1427/ Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement Norhafiza Binti Mohd Zukepeli, Norhafiza TJ Mechanical engineering and machinery Aboveground atmospheric storage tank is one of the important equipment in plant operation. One of the possible failures which normally overlooked is the failure of the tank due to settlement. The objective of this project is to conduct a deformation analysis based on bending moment theory and finite element analysis on deformation and bending moment distribution along section of bottom plate of aboveground storage tank that might occur during edge settlement. The results that represented the effect of edge settlement amplitude, plate thickness and foundation stiffness coefficient was generated. Using the used model, the prediction of relationship between settlement, foundation stiffness and plate thickness can be developed and future prevention of tank settlement may be applied. Comparison of the result with the API Standard 653 shows that the API Standard 653 which does not take into account of the effect of tank plate thickness, foundation stiffness, plate shell junction stiffness gives in general a conservative estimation of the allowable edge settlement limit. Using the model, for 7.5mm bottom plate thickness and 1m radial length the settlement limit is equals to 36mm which is about 20% more than the limit set by API Standard 653 for the same thickness and radial length which is 30.8mm. Universiti Teknologi Petronas 2010 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/1427/1/Norhafiza_Binti_Mohd_Zukepeli_8064.pdf application/pdf en http://utpedia.utp.edu.my/1427/4/Quartos_Radintletse_Maremo_Mamabolo.pdf Norhafiza Binti Mohd Zukepeli, Norhafiza (2010) Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement. Universiti Teknologi Petronas. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Norhafiza Binti Mohd Zukepeli, Norhafiza
Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement
description Aboveground atmospheric storage tank is one of the important equipment in plant operation. One of the possible failures which normally overlooked is the failure of the tank due to settlement. The objective of this project is to conduct a deformation analysis based on bending moment theory and finite element analysis on deformation and bending moment distribution along section of bottom plate of aboveground storage tank that might occur during edge settlement. The results that represented the effect of edge settlement amplitude, plate thickness and foundation stiffness coefficient was generated. Using the used model, the prediction of relationship between settlement, foundation stiffness and plate thickness can be developed and future prevention of tank settlement may be applied. Comparison of the result with the API Standard 653 shows that the API Standard 653 which does not take into account of the effect of tank plate thickness, foundation stiffness, plate shell junction stiffness gives in general a conservative estimation of the allowable edge settlement limit. Using the model, for 7.5mm bottom plate thickness and 1m radial length the settlement limit is equals to 36mm which is about 20% more than the limit set by API Standard 653 for the same thickness and radial length which is 30.8mm.
format Final Year Project
author Norhafiza Binti Mohd Zukepeli, Norhafiza
author_facet Norhafiza Binti Mohd Zukepeli, Norhafiza
author_sort Norhafiza Binti Mohd Zukepeli, Norhafiza
title Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement
title_short Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement
title_full Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement
title_fullStr Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement
title_full_unstemmed Stress Analysis Of Aboveground Atmospheric Storage Tank Due To Edge Settlement
title_sort stress analysis of aboveground atmospheric storage tank due to edge settlement
publisher Universiti Teknologi Petronas
publishDate 2010
url http://utpedia.utp.edu.my/1427/1/Norhafiza_Binti_Mohd_Zukepeli_8064.pdf
http://utpedia.utp.edu.my/1427/4/Quartos_Radintletse_Maremo_Mamabolo.pdf
http://utpedia.utp.edu.my/1427/
_version_ 1739830776203051008