Heat Spreading Performance of Vapor Chamber

The thermal performance of a vapor chamber was investigated to determine the heat spreading effect. A vapor chamber together with a fin heat sink, aluminium block heat spreader and heating element were assembled together to investigate the thermal heat spreading resistance under natural and force co...

Full description

Saved in:
Bibliographic Details
Main Author: Lee, Kok Hong
Format: Final Year Project / Dissertation / Thesis
Published: 2015
Subjects:
Online Access:http://eprints.utar.edu.my/1770/1/Heat_Spreading_Performance_of_Vapor_Chamber.pdf
http://eprints.utar.edu.my/1770/
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The thermal performance of a vapor chamber was investigated to determine the heat spreading effect. A vapor chamber together with a fin heat sink, aluminium block heat spreader and heating element were assembled together to investigate the thermal heat spreading resistance under natural and force convection air cooling. The overall measurement of the vapor chamber was 139 x 123 x 4.7mm. A finned heat sink was used. Electrical heating power input varied from 10W to 40W. The experimental results showed that forced convection air cooling performance better than natural convection. The thermal heat spreading resistance of the fin heat sink was around 0.17K/W to 0.18K/W. The thermal heat spreading resistance of vapor chamber was kept constant which is around 0.14K/W to 0.28K/W under natural and force convection. Furthermore, the aspect ratio of the larger heating element is almost the same temperature to the smaller heating element under natural and force convection.